PubMed Health⌕ Search

Biomedical subjects

D Senft

Publications and source records attributed to D Senft.

6 recordsLinked to original sources

Effect of periosteal stripping on cortical bone perfusion: a laser doppler study in sheep.

The goals of internal fixation are an accurate reduction and stable fixation in the presence of adequate bony vascularity. This can be achieved by a variety of means including plate fixation. A certain amount of periosteal stripping is necessary for proper open reduction of a fracture and for proper plate application. With displaced diaphyseal fractures, cortical bone perfusion (CBP) is already compromised. Further damage, in terms of periosteal stripping for plate fixation, may not be acceptable. Little information is available as to what extent the periosteum contributes to cortical bone perfusion. The purpose of this study was to determine the acute effects of periosteal stripping on cortical bone perfusion in a sheep tibia model. Twenty-three sheep were operated on and had the medial aspect of their right tibia exposed. Cortical bone perfusion measurements were obtained using laser Doppler flowmetry prior to periosteal stripping and after periosteal stripping. The results of this study show that the cortical bone perfusion significantly decreased by 20% after periosteal stripping over the entire length of the tibia. We therefore conclude that the periosteum contributes to diaphyseal bone perfusion and that it is important to preserve this source with fractures where blood supply is already significantly compromised.

Animals↗

Cortical bone perfusion in plated fractured sheep tibiae.

The limited contact dynamic compression plate and partial contact plate were designed to decrease contact with cortical bone in an attempt to decrease cortical ischemia, remodeling, and eventual porosis under the plate after use of standard dynamic compression plates. This study quantified cortical bone blood flow beneath the plate with these three different designs in a sheep tibia fracture model. In 18 skeletally immature sheep, the right tibia was fractured and then was internally fixed with an interfragmentary screw and a dynamic compression plate, limited contact dynamic compression plate, or partial contact plate. At 12 weeks, cortical bone perfusion was assessed with laser Doppler flowmetry in nine areas beneath the plate. The baseline (before fracture) cortical bone cell flux averaged 100 +/- 60 mV. After fracture, this decreased to 60 +/- 48 mV (p < 0.0003); immediately after plating, the perfusion averaged 29 +/- 25 mV (p < 0.01). Cortical bone perfusion then increased to 106 +/- 52, 165 +/- 71, and 163 +/- 71 mV at 2, 6, and 12 weeks after fracture (p < 0.001 for all when compared with values after plating). No significant differences in cortical perfusion were seen between the types of plate. Cortical porosity under the plate was assessed with digital density analysis of microradiographs of this region. No significant difference was seen between the types of plate in this analysis or in biomechanical and disulphine blue perfusion analysis. Thus, no significant advantage was seen for the new plate designs used in this model. This lack of advantage may be a result of the immature animals used in the study, the protocol for blood flow measurement, the invasive periosteal stripping employed to create the fracture, or all three. However, as advantages with the new plate designs have been seen in other studies, this area warrants further investigation.

Analysis of Variance↗

Geometric changes in the cervical spinal canal during impact.

SUMMARY OF BACKGROUND DATA: Although the extent of injury after cervical spine fracture can be visualized by imaging, the deformations that occur in the spinal canal during injury are unknown. STUDY DESIGN: This study compared spinal canal occlusion and axial length changes occurring during a simulated compressive burst fracture with the residual deformations after the injury. METHODS: Canal occlusion was measured from changes in pressure in a flexible tube with fluid flowing through it, placed in the canal space after removal of the cord in cadaver specimens. To measure canal axial length, cables were fixed in C1 and led through the foramen transversarium from C2-T1, then out through the base, where they were connected to the core rods of linearly variable differential transformers (LVDT). Axial compressive burst fractures were created in each of ten cadaveric cervical spine specimens using a drop-weight, while force, distraction, and occlusion were monitored throughout the injury event. Pre- and post-injury radiographs and computed tomography scans compared transient and post-injury spinal canal geometry changes. RESULTS: In all cases, severe compressive injuries were produced. Three had an extension component in addition to compression of the vertebra and retropulsion of bone into the canal. The mean post-injury axial height loss measured from radiographs was only 35% of that measured transiently (3.1 mm post-injury, compared with 8.9 mm measured transiently), indicating significant recovery of axial height after impact. Post-injury and transient height loss were not significantly correlated (r2 = 0.230, P = 0.16) demonstrating that it is not a good measure of the extent of injury. Similarly, mean post injury canal area was 139% of the minimum area measured during impact, indicating recovery of canal space, and post-injury and transient values were not significantly correlated (r2 = 0.272, P = 0.12). Mean post-injury midsagittal diameter was 269% of the minimum transient diameter and showed a weak but significant correlation (r2 = 0.481, P = 0.03). CONCLUSIONS: Two potential spinal cord injury-causing mechanisms in axial bursting injuries of the cervical spine are occlusion and shortening of the canal. Post-injury radiographic measurements significantly underestimate the actual transient injury that occurs during impact.

Biomechanical Phenomena↗

Cortical bone blood flow in reamed and unreamed locked intramedullary nailing: a fractured tibia model in sheep.

We compared the effects of reamed versus unreamed locked intramedullary nailing on cortical bone blood flow in a fractured sheep tibia model. A standardized spiral fracture was created by three-point bending with torsion, and each tibia was stabilized by insertion of a locked intramedullary nail. Eleven animals were randomized into two groups: one that had reaming before nail insertion and one that did not. Blood flow was measured in real time using laser Doppler flowmetry. Cortical bone perfusion measurements were made at three locations (proximal diaphysis, fracture site, distal diaphysis) and at eight time intervals (prefracture, postfracture, postreaming, postnail insertion, postlocking, and at 2-, 6-, and 12-week follow-up). All animals were killed at 12 weeks postoperatively. After reamed nail insertion, cortical bone perfusion was significantly decreased (p < 0.0009). After unreamed nail insertion, perfusion was decreased less (p < 0.003). Insertion of locking screws did not affect blood flow. Cortical bone perfusion was greater in the unreamed group at completion of the procedure (p < 0.011), at 2-week follow-up (p < 0.006) and at 6-week follow-up (p < 0.027). The findings suggest that cortical revascularization had occurred by 6 weeks in the unreamed group but not until 12 weeks in the reamed group. The study demonstrates that cortical circulation is spared to a greater degree by unreamed nailing. This may be advantageous in severe open tibial fractures where blood supply is already significantly compromised.

Animals↗

Cortical bone microperfusion: response to ischemia and changes in major arterial blood flow.

In order to investigate the effects of short-term ischemia on cortical bone microperfusion, an isolated porcine tibia diaphyseal preparation based on intact nutrient vessels was developed. Laser Doppler flowmetry (LDF) was utilized to assess continuously the cortical microcirculation and the response to short-term ischemia. The femoral artery was isolated and clamped to develop the condition of bone ischemia. On release of the clamp, reactive hyperemia was documented in all animals. Using a roller pump connected to a segment of femoral artery, the same preparation was utilized to investigate the effect of a changing femoral artery flow on the cortical microcirculation. A positive correlation between LDF output and change in arterial inflow (r = 0.64) was defined. This model has the potential for studying the effect of ischemia on bone cell viability.

Animals↗