Desirable performance criteria for quantitative measurements in medical laboratories based on biological analyte variation--hindrances to reaching some and reasons to surpass some.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to D Stöckl.
Explore the source record for details and available documents.
We describe the testing of transferability of candidate Reference Methods developed by INSTAND for cholesterol, creatinine, uric acid, and glucose. The methods are based on isotope dilution-gas chromatography--mass spectrometry. The study consisted of two parts: setup of the methods and self-evaluation for readiness in the collaborating laboratory, followed by independent measurements in parallel with INSTAND. Criteria used for judging the transferability and general reliability of the candidate Reference Methods were: the accuracy and precision of the collaborating laboratory and the agreement between the two laboratories. The accuracy was judged from the results on the Standard Reference Material 909 from the National Institute of Standards and Technology. For all analytes except glucose the bias from the certified value was < 0.7%. The mean intralaboratory imprecision ranged from 0.66% to 1.24%. The agreement between the results was tested by an advanced linear-regression analysis and Student's t-test. In general, the results demonstrate that the candidate Reference Methods developed by INSTAND can be successfully transferred without loss of their inherent precision and accuracy.
In Germany, the target values for External Quality Assessment (EQA) and internal accuracy control are determined by Reference Methods for several analytes, including cholesterol, creatinine, uric acid, and glucose. We present candidate Reference Methods for these compounds, based on isotope dilution-gas chromatography--mass spectrometry methods that have been developed at INSTAND, one of the two official Germany EQA reference institutions. Each Reference Method target value is calculated from six independent measurements performed on three different days. The mean method CVs ranged from 0.66% for glucose to 0.96% for creatinine. The inaccuracy (bias) of the methods is < 0.7%, as compared with the Standard Reference Material 909 of the National Institute of Standards and Technology. The maximum total error of a Reference Method value, including the 95% confidence interval and systematic errors, is < 2.3%. The presented candidate Reference Methods have been successfully used to set target values in the German EQA scheme and the internal accuracy control of routine laboratories.
The formation of a new derivative of aldosterone with heptafluorobutyric anhydride for gas chromatography/mass spectrometry (GC/MS) is presented. The highest and also the most prominent ion of this derivative is observed at m/z 734. The new derivative is, under the described conditions, reproducibly formed, is stable and has good gas chromatographic properties. These characteristics make the new derivative extremely suitable for selective, sensitive, precise and accurate analysis of aldosterone in serum by GC/MS in association with isotope dilution. This is proven by the agreement between the measurement results obtained by two laboratories for samples of three batches of lyophilized control serum. The sample pretreatment procedures used in each laboratory are described.
ent-Kaurene biosynthesis as a prerequisite for gibberellin (GA) biosynthesis was studied in germinating Hordeum vulgare L., cv Himalaya caryopses and correlated, in time, with the appearance of alpha-amylase activity. The rate of ent-kaurene biosynthesis was estimated by inhibiting its further metabolism with plant growth retardants (triapenthenol or tetcyclacis) and measuring its accumulation by isotope dilution using combined gas chromatographymass spectrometry. In the inhibitor-treated caryopses, ent-kaurene accumulation began approximately 24 hours after imbibition and proceeded at a rate of about 1 to 2 picomoles per hour per caryopsis, depending on the batch of seeds. In the absence of inhibitor, ent-kaurene did not accumulate, indicating that it is normally turned over rapidly, presumably to further intermediates of the GA biosynthesis pathway and eventually to GAs. ent-Kaurene accumulation occurred almost exclusively in the shoot, which is, therefore, probably the site of biosynthesis. alpha-Amylase production began between 30 and 36 hours after imbibition and, thus, correlated well with de novo GA biosynthesis, as estimated from ent-kaurene accumulation. However, inhibition of ent-kaurene oxidation by plant growth retardants did not reduce the alpha-amylase production significantly, although it did reduce shoot elongation. We conclude that ent-kaurene is produced in the shoot and is continuously converted to GA, which is essential for normal shoot elongation, but not for the production of alpha-amylase in the aleurone layer.