Ability of MR cholangiography to reveal stent position and luminal diameter in patients with biliary endoprostheses: in vitro measurements and in vivo results in 30 patients.

OBJECTIVE: Our goal was to evaluate the ability of MR cholangiography to show stent position and luminal diameter in patients with biliary endoprostheses. MATERIALS AND METHODS: Susceptibility artifacts were evaluated in vitro in three different stent systems (cobalt alloy-based, nitinol-based, and polyethylene) using two breath-hold sequences (rapid acquisition with relaxation enhancement, half-Fourier acquisition single-shot turbo spin echo) on a 1.5-T MR imaging system. The size of the stent-related artifact was measured, and the relative stent lumen was calculated. In vivo stent position and patency were determined in 30 patients (10 cobalt alloy-based stents, five nitinol-based stents, and 15 polyethylene stents). RESULTS: In vitro, the susceptibility artifact of the cobalt stent caused complete obliteration of the stent lumen. The relative stent lumens of the nitinol-based and polyethylene stents were 38-50% and 67-100%, respectively. In vivo, all stents were patent at the time of imaging. The position of the cobalt alloy-based stent could be determined in nine of 10 patients, but stent patency could not be evaluated. Stent position of nitinol stents could not be adequately evaluated in any of the five patients, and internal stent diameter could be visualized in only one patient. In nine of 15 patients, the fluid column within the implanted polyethylene stent was seen on MR cholangiography. CONCLUSION: The internal stent lumen could be visualized in most patients with an indwelling polyethylene stent, but not in patients with cobalt alloy- or nitinol-based stents.

Adult↗

MRI-guided radiofrequency thermal ablation of implanted VX2 liver tumors in a rabbit model: demonstration of feasibility at 0.2 T.

Successful radiofrequency (RF) thermal ablation was performed on VX2 tumors implanted in 23 rabbit livers under magnetic resonance (MR) guidance using a C-arm-shaped low-field 0.2 T system. RF application and immediate postprocedure MRI of all animals was performed [T2-weighted, turbo short tau inversion recovery (STIR), T1-weighted before and after gadopentetate dimeglumine administration). Follow-up MRI with a superparamagnetic iron oxide (SPIO) contrast medium was performed in nine rabbits at 2 weeks and in four rabbits at 1 month post RF ablation. All livers were harvested for pathologic examination. T2-weighted and turbo-STIR images demonstrated the highest tumor-to-RF-thermal lesion contrast-to-noise ratios (CNRs; means 4.5 and 3.8, respectively) on postprocedure images; this was redemonstrated at 2- and 4-week follow-up imaging. T2-weighted imaging never overestimated pathologic lesion size by more than 2 mm, and the radiologic-pathologic correlation coefficient was not less than 0.90. In conclusion, MRI-guided RF thermal ablation in implanted liver tumor is feasible using a C-arm-shaped low-field 0.2 T system. The thermal lesion size can be most accurately monitored with T2-weighted and turbo-STIR images.

Animals↗

Effects of superparamagnetic iron oxide on radio-frequency-induced temperature distribution: in vitro measurements in polyacrylamide phantoms and in vivo results in a rabbit liver model.

PURPOSE: To determine whether contrast medium containing superparamagnetic iron oxide (SPIO) alters radio-frequency (RF)-related temperature distribution in acrylamide phantoms and in an in vivo model. MATERIALS AND METHODS: In nine acrylamide phantoms with increasing SPIO content, RF was applied with simultaneous measurement of temperature profile along the probe track. Additionally, magnetic resonance imaging-guided RF ablation was performed in the liver of six rabbits after the intravenous administration of SPIO (0.05 mL per kilogram of body weight) 40 minutes prior to ablation (SPIO group) and in another six rabbits without prior SPIO administration (control group). Coagulation diameter was evaluated on the basis of postprocedural imaging and subsequent gross pathologic findings. Statistical analysis was performed with the Student t test. RESULTS: In the phantoms, progressive increases in iron content resulted in higher temperatures along the RF electrode track (P < .05). In the in vivo model, however, SPIO at physiologic concentrations did not significantly increase the diameter of coagulation on the basis of either postprocedural imaging or subsequent gross pathologic findings. Additionally, no significant differences were seen in other RF-related parameters including impedance, voltage, current, and grounding pad temperature. CONCLUSION: Administration of SPIO in conjunction with RF ablation of focal liver lesions is feasible and safe, but no significant difference in the extent of induced coagulation can be expected.

Acrylic Resins↗