Experimental study of liver dysfunction evaluated by direct indocyanine green clearance using near infrared spectroscopy.

BACKGROUND: Blood clearance of indocyanine green (ICG) is an objective test of liver function. Hepatic ICG clearance can now be measured directly using near infrared spectroscopy (NIRS). The aim of this study was to evaluate measurement of hepatic ICG clearance by NIRS in an animal model of acute hepatic dysfunction. METHODS: New Zealand white rabbits (n = 36) underwent laparotomy for liver exposure. Hepatic blood flow and microcirculation were measured along with hepatic ICG concentration by NIRS. Hepatic ICG clearance was measured in groups of six animals after reduction of the hepatic blood flow by hepatic artery occlusion and portal vein partial occlusion, lobar ischaemia and reperfusion (I/R), colchicine administration and bile duct ligation. Hepatic ICG uptake and excretion rates were calculated by a non-linear least square curve fitting method from the ICG concentration-time curve. RESULTS: There was a significant positive correlation between hepatic ICG rate of uptake and both hepatic blood flow and microcirculation (r = 0.79, P = 0.0001; r = 0.59, P = 0.005 respectively). I/R resulted in a significant reduction of both the rates of ICG uptake (mean(s.d.) 0. 85(0.59) min-1; P = 0.0002 versus control) and ICG excretion (0. 020(0.006) min-1; P = 0.02 versus control). Colchicine decreased the rate of hepatic ICG excretion (0.030(0.010) min-1; P = 0.02 versus control) as did bile duct ligation (0.002(0.001) min-1; P = 0.01 versus control). CONCLUSION: Measurement of hepatic ICG clearance by NIRS is a promising technique for assessing hepatic parenchymal dysfunction and may have application in liver surgery and transplantation.

Animals↗

Photon migration in non-scattering tissue and the effects on image reconstruction.

Photon propagation in tissue can be calculated using the relationship described by the transport equation. For scattering tissue this relationship is often simplified and expressed in terms of the diffusion approximation. This approximation, however, is not valid for non-scattering regions, for example cerebrospinal fluid (CSF) below the skull. This study looks at the effects of a thin clear layer in a simple model representing the head and examines its effect on image reconstruction. Specifically, boundary photon intensities (total number of photons exiting at a point on the boundary due to a source input at another point on the boundary) are calculated using the transport equation and compared with data calculated using the diffusion approximation for both non scattering and scattering regions. The effect of non-scattering regions on the calculated boundary photon intensities is presented together with the advantages and restrictions of the transport code used. Reconstructed images are then presented where the forward problem is solved using the transport equation for a simple two-dimensional system containing a non-scattering ring and the inverse problem is solved using the diffusion approximation to the transport equation.

Algorithms↗

Use of mitochondrial inhibitors to demonstrate that cytochrome oxidase near-infrared spectroscopy can measure mitochondrial dysfunction noninvasively in the brain.

The use of near-infrared spectroscopy to measure noninvasively changes in the redox state of cerebral cytochrome oxidase in vivo is controversial. We therefore tested these measurements using a multiwavelength detector in the neonatal pig brain. Exchange transfusion with perfluorocarbons revealed that the spectrum of cytochrome oxidase in the near-infrared was identical in the neonatal pig, the adult rat, and in the purified enzyme. Under normoxic conditions, the neonatal pig brain contained 15 micromol/L deoxyhemoglobin, 29 micromol/L oxyhemoglobin, and 1.2 micromol/L oxidized cytochrome oxidase. The mitochondrial inhibitor cyanide was used to determine whether redox changes in cytochrome oxidase could be detected in the presence of the larger cerebral hemoglobin concentration. Addition of cyanide induced full reduction of cytochrome oxidase in both blooded and bloodless animals. In the blooded animals, subsequent anoxia caused large changes in hemoglobin oxygenation and concentration but did not affect the cytochrome oxidase near-infrared signal. Simultaneous blood oxygenation level-dependent magnetic resonance imaging measurements showed a good correlation with near-infrared measurements of deoxyhemoglobin concentration. Possible interference in the near-infrared measurements from light scattering changes was discounted by simultaneous measurements of the optical pathlength using the cerebral water absorbance as a standard chromophore. We conclude that, under these conditions, near-infrared spectroscopy can accurately measure changes in the cerebral cytochrome oxidase redox state.

Animals↗

Oxidation and reduction of cytochrome oxidase in the neonatal brain observed by in vivo near-infrared spectroscopy.

Near-infrared spectroscopy was used to determine the relationship between the redox state of mitochondrial cytochrome oxidase CuA and haemoglobin oxygenation in the isoflurane-anaesthetized neonatal pig brain. Adding 7% CO2 to the inspired gases increased the total haemoglobin concentration by 8 microM and oxidized CuA by 0.2 microM. Decreasing the inspired oxygen fraction to zero for 90 s dropped the oxyhaemoglobin concentration by 27 microM and reduced CuA by 1.8 microM. However, no change in the CuA redox state was observed until oxyhaemoglobin had decreased by more than 10 microM. The response of the CuA redox state to these stimuli was very similar following 80% replacement of the haemoglobin by a perfluorocarbon blood substitute; this demonstrates that the results in the normal haematocrit were not a spectral artefact due to the high haemoglobin/cytochrome oxidase ratio. We conclude that the large reductions in the CuA redox state during anoxia are caused by a decrease in the rate of oxygen delivery to the cytochrome oxidase oxygen binding site; the small oxidations, however, are likely to reflect the effects of metabolic changes on the redox state of CuA, rather than increases in the rate of oxygen delivery.

Animals↗

The relationship of oxygen delivery to absolute haemoglobin oxygenation and mitochondrial cytochrome oxidase redox state in the adult brain: a near-infrared spectroscopy study.

Near-infrared spectroscopy was used to determine the effect of changes in the rate of oxygen delivery to the adult rat brain on the absolute concentrations of oxyhaemoglobin, deoxyhaemoglobin and the redox state of the CuA centre in mitochondrial cytochrome oxidase. The cytochrome oxidase detection algorithm was determined to be robust to large changes in haemoglobin oxygenation and concentration. By assuming complete haemoglobin deoxygenation and CuA reduction following mechanical ventilation on 100% N2O, the absolute concentration of oxyhaemoglobin (35 microM), deoxyhaemoglobin (27 microM) and the redox state of CuA (82% oxidized) were calculated in the normal adult brain. The mean arterial blood pressure was decreased by exsanguination. When the pressure reached 100 mmHg, haemoglobin oxygenation started to fall, but the total haemoglobin concentration and oxidized CuA levels only fell when cerebral blood volume autoregulation mechanisms failed at 50 mmHg. Haemoglobin oxygenation fell linearly with decreases in the rate of oxygen delivery to the brain, but the oxidized CuA concentration did not start to fall until this rate was 50% of normal. The results suggest that the brain maintains more than adequate oxygen delivery to mitochondria and that near-infrared spectroscopy may be a good measure of oxygen insufficiency in vivo.

Animals↗

A theoretical study of the signal contribution of regions of the adult head to near-infrared spectroscopy studies of visual evoked responses.

Near-infrared (NIR) spectroscopy has been used in studies of the cerebral hemodynamic response to visual processing. In this paper, we present theoretical results from finite element and Monte Carlo modeling in order to help understand the contribution to the NIR signal from different parts of the head. The results from the models show that at the typical optode spacings used in these studies, an infrared spectroscopy measurement of intensity is sensitive to the outer 1-2 mm of the cortical gray matter and the partial optical path length in the gray matter is approximately 10 mm, compared with a total optical path length of 400 mm. When the NIR measurement is of change in mean photon arrival time (or phase shift), the signal comes from the upper 2-4 mm of the cortical surface and there is an increased lateral spread of the contributing tissue. We predict that for a 4-cm separation of input and detection optodes at 800 nm, a 1 microM change in hemoglobin concentration in the cortex corresponds to an attenuation change of approximately 0.001 OD (optical density) or 1 ps mean time change. Movement of the brain caused by this increase in volume will cause an absorption change of approximately half this magnitude, but does not affect the photon arrival time at 4-cm spacing. A discrepancy between the predicted and the experimentally measured intensities may support the supposition that the NIR signal is actually very sensitive to changes occurring in the pial cerebral vessels lying on the brain surface.

Adult↗

Measurement of electrical current density distribution within the tissues of the head by magnetic resonance imaging.

Images of the electrical current distribution in an intact piglet head, measured by MRI, are presented for the first time. Remarkable differences in the distribution of the electrical current between live and post mortem studies are found. After death, there is a decrease of 62% in the current reaching the brain, compared with the situation in the living animal. This reduction is associated with the increase in the brain impedance after death, which agrees with previous in vivo studies.

Animals↗

Experimental and theoretical comparison of NIR spectroscopy measurements of cerebral hemoglobin changes.

Two near-infrared spectroscopy (NIRS) methods are available for measuring changes (Delta) in total cerebral hemoglobin concentration (CHC): 1) a continuous measurement of the changes in total hemoglobin concentration (Delta[Hb]tot) and 2) the difference between two absolute measurements of CHC, each derived from a small, controlled change in inspired O2 fraction. This paper investigates the internal consistency of these two methods by using an experimental and theoretical comparison. NIRS was used to measure [Hb]tot in five newborn piglets before and after a change in arterial PCO2. Delta[Hb]tot demonstrated a low coefficient of variation of 2.8 +/- 2.8 (SD) % which allowed changes in CO2-cerebral blood volume reactivity to be clearly discriminated. However, a high coefficient of variation of 22.8 +/- 3.5% on the DeltaCHC measurements obscured any CO2 reactivity changes. A theoretical analysis demonstrates the effects of optical pathlength, background absorption, scatter, and blood vessel diameter on both methods. For more accurate monitoring of CHC, individual measurements of optical pathlength and more accurate pulse oximetry are required.

Animals↗

Artefacts in MR images of electrical current distribution.

Artefacts in images of electrical current distribution measured by magnetic resonance imaging (MRI) are presented. These artefacts, caused by the effects of the connecting cables used to apply the electrical current to the object during the MRI scan, can lead to an underestimation of the magnitude of the electrical current measured in the experiment. The size of this underestimate depends upon the experimental geometry, but in the experiments and simulations described here, performed with a cylindrical phantom approximately 8 cm long and 8 cm in diameter, the difference can be 27%. These artefacts are reduced if the connecting cables are rigidly fixed to the object so that the induced magnetic field is correctly measured during the MRI experiment.

Artifacts↗

Investigation of the effect of discrete absorbers upon the measurement of blood volume with near-infrared spectroscopy.

This paper derives an analytical model for investigating the effect of the distribution of absorbers upon light attenuation in a scattering medium. Results from this are found to agree with those of Monte Carlo simulations. The implications of this model are then examined for their likely effect upon the measurement of cerebral blood volume (CBV) using near-infrared (NIR) spectroscopy. We conclude that, given the small diameter of the majority of cerebral blood vessels, the distribution of the blood will have little effect upon the measurement of CBV. Where changes to the blood volume occur in the larger (> 0.2 mm diameter) vessels on the surface of the brain, NIR spectroscopy is likely to underestimate the change.

Animals↗

Optical imaging in medicine: I. Experimental techniques.

The overwhelming scatter which occurs when optical radiation propagates through tissue severely limits the ability to image internal structure using measurements of transmitted intensity. A broad range of methods has been proposed during the past decade or so in order to improve imaging performance. Direct methods involve isolating an unscattered or least-scattered component of transmitted scattered light. Indirect methods generally involve measuring some characteristic of the temporal distribution of transmitted light, or an equivalent in the frequency domain, and obtaining a computational solution to the inverse problem. In this paper, we review the experimental techniques which have been proposed in order to explore both direct and indirect imaging. The relative merits and limitations of the various experimental methods are discussed, and we consider the future directions and likelihood of success of optical imaging in medicine.

Diagnostic Imaging↗

Parallel operation of Monte Carlo simulations on a diverse network of computers.

Monte Carlo simulation methods are frequently used to determine light propagation in tissue and x-ray propagation as well as for solving other non-medically related problems. Such techniques are computationally slow, with the signal to noise ratio improving only as the square root of computation time. We present a method for the design of a Monte Carlo program that is capable of running on up to 24 computers simultaneously, with there being very few restrictions on the computer types as long as they run on a common network. This parallel operation is useful when the run time is expected to be long. A mixture of PCs and Sun workstations have been successfully used. The program as described was designed for the simulation of light transport in tissue, but the technique of achieving simple simultaneous execution on a number of different computers could be used wherever Monte Carlo techniques are used.

Biophysical Phenomena↗