PubMed Health⌕ Search

Biomedical subjects

D T Smith

Publications and source records attributed to D T Smith.

At least 19 recordsLinked to original sources

Whisker-reinforced dental core buildup composites: effect of filler level on mechanical properties.

The strength and toughness of dental core buildup composites in large stress-bearing restorations need to be improved to reduce the incidence of fracture due to stresses from chewing and clenching. The aims of the present study were to develop novel core buildup composites reinforced with ceramic whiskers, to examine the effect of filler level, and to investigate the reinforcement mechanisms. Silica particles were fused onto the whiskers to facilitate silanization and to roughen the whisker surface for improved retention in the matrix. Filler level was varied from 0 to 70%. Flexural strength, compressive strength, and fracture toughness of the composites were measured. A nano-indentation system was used to measure elastic modulus and hardness. Scanning electron microscopy (SEM) was used to examine the fracture surfaces of specimens. Whisker filler level had significant effects on composite properties. The flexural strength in MPa (mean +/- SD; n = 6) increased from (95+/-15) for the unfilled resin to (193+/- 8) for the composite with 50% filler level, then slightly decreased to (176+/-12) at 70% filler level. The compressive strength increased from (149+/-33) for the unfilled resin to (282+/-48) at 10% filler level, and remained equivalent from 10 to 70% filler level. Both the modulus and hardness increased monotonically with filler level. In conclusion, silica particle-fused ceramic single-crystalline whiskers significantly reinforced dental core buildup composites. The reinforcement mechanisms appeared to be crack deflection and bridging by the whiskers. Whisker filler level had significant effects on the flexural strength, compressive strength, elastic modulus, and hardness of composites.

Bisphenol A-Glycidyl Methacrylate↗

Indentation modulus and hardness of whisker-reinforced heat-cured dental resin composites.

OBJECTIVES: Recent studies showed that ceramic whisker reinforcement imparted a two-fold increase in the strength of dental composites. The aim of this study was to investigate the indentation response and measure the elastic modulus, hardness, and brittleness of whisker-reinforced heat-cured resin composites as a function of filler level, heat-cure temperature, and heat-cure duration. METHODS: Silica particles were fused onto silicon nitride whiskers to facilitate silanization and to roughen the whiskers for improved retention in matrix. Whisker filler mass fractions of 0, 20, 40, 60, 70, 74 and 79% were tested. Heat-cure temperature ranged from 100 to 180 degrees C, and duration from 10 min to 24 h. A nano-indentation system enabled the measurement of elastic modulus. Fracture toughness was measured and composite brittleness index was calculated. An inlay/onlay composite and a prosthetic composite were tested as controls. RESULTS: Whisker filler level and heat-cure duration had significant effects on composite properties, while heat-cure temperature had non-significant effects. The whisker composite with 79% filler level had a modulus in GPa (mean (SD); n = 6) of 26.9 (1.0), significantly higher than 15.1 (0.2) of an inlay/onlay control, and 16.1 (0.3) of a prosthetic control (Tukey's multiple comparison test; family confidence coefficient = 0.95). The fracture toughness in MPa.m1/2 was 2.22 (0.26) for the whisker composite, higher than 0.95 (0.11) for inlay/onlay control, and (1.13 +/- 0.19) for prosthetic control. The brittleness index was (0.49 +/- 0.07) for whisker composite, lower than (1.02 +/- 0.12) for inlay/onlay control and (0.63 +/- 0.13) for prosthetic control. SIGNIFICANCE: Whisker filler level had a profound influence, heat-cure duration had significant effects, while temperature did not have significant effects, on the properties of whisker composite. The whisker composite had significantly higher elastic modulus and fracture toughness, and lower brittleness than the inlay/onlay and prosthetic controls.

Analysis of Variance↗

Indentation damage and mechanical properties of human enamel and dentin.

Understanding the mechanical properties of human teeth is important to clinical tooth preparation and to the development of "tooth-like" restorative materials. Previous studies have focused on the macroscopic fracture behavior of enamel and dentin. In the present study, we performed indentation studies to understand the microfracture and deformation and the microcrack-microstructure interactions of teeth. It was hypothesized that crack propagation would be influenced by enamel rods and the dentino-enamel junction (DEJ), and the mechanical properties would be influenced by enamel rod orientation and tooth-to-tooth variation. Twenty-eight human third molars were used for the measurement of hardness, fracture toughness, elastic modulus, and energy absorbed during indentation. We examined the effect of enamel rod orientation by propagating cracks in the occlusal surface, and in the axial section in directions parallel and perpendicular to the occlusal surface. The results showed that the cracks in the enamel axial section were significantly longer in the direction perpendicular to the occlusal surface than parallel. The cracks propagating toward the DEJ were always arrested and unable to penetrate dentin. The fracture toughness of enamel was not single-valued but varied by a factor of three as a function of enamel rod orientation. The elastic modulus of enamel showed a significant difference between the occlusal surface and the axial section. It is concluded that the cracks strongly interact with the DEJ and the enamel rods, and that the mechanical properties of teeth are functions of microstructural orientations; hence, single values of properties (e.g., a single toughness value or a single modulus value) should not be used without information on microstructural orientation.

Analysis of Variance↗

Recent developments in the design and construction of facilities for the production of human injectables.

The pressures imposed upon pharmaceutical production managers are such that insufficient time is available to plan and develop new pharmaceutical facilities. Standards and codes of practice are available but the relevant data is not presented in a form which would enable the reader to readily access. This paper attempts to highlight the relevant extracts and to visually demonstrate some practical proprietary solutions. It is acknowledged that in some aspects the designer will find it necessary to deviate from the Code and the Standards in the interests of achieving a practical process solution. This paper will provide an awareness of the necessary design parameters such that any deviation judgements have been fully considered.

Drug Industry↗

Initial clinical evaluation of a whole body nuclear magnetic resonance (NMR) tomograph.

A nuclear magnetic resonance (NMR) imaging system is described, and preliminary results from its clinical use are presented. The properties and detection of the magnetisation due to hydrogen protons are outlined, and a rotating frame is introduced to describe the motion of the magnetisation. Radiofrequency (RF) pulses are used to rotate the magnetisation, and slice selection is achieved using a 90 degree RF pulse and a magnetic field gradient. Data acquisition and image reconstruction are explained. Three scanning sequences are described: repeated free induction decay (FID), inversion - recovery, and spin-echo. These sequences produce images whose pixel values have different dependencies on hydrogen proton density, T1 and T2. Inversion-recovery images show striking differentiation between grey and white matter in the brain. The absence of bone artifact is a significant advantage over X-ray computed tomography in the posterior fossa, where rapid repeated FID sequences can also be used to demonstrate flow effects. The considerable soft tissue contrast available with NMR is of value in demonstrating disease within the liver where T1 appears to be sensitive but relatively nonspecific diagnostic parameter. High resolution scans are of value in demonstrating the adrenal gland and spinal cord.

Brain↗

Magnetic resonance properties of hydrogen: imaging the posterior fossa.

Posterior fossa scans were performed on five healthy volunteers using a nuclear magnetic resonance (NMR) machine constructed by Thorn-EMI Ltd. Three different NMR scanning sequences were used. In the first, a type of saturation-recovery technique was used to produce images strongly dependent on the density of hydrogen nuclei, but with some dependence on the spin-lattice relaxation time (T1). In the second, an inversion-recovery technique was used to produce images with a stronger dependence on the spin-lattice relaxation time. In the third, a spin-echo technique was used to obtain images with a dependence on the spin-spin relaxation time (T2). All three types of NMR image were unaffected by bone artifact. Visualization of brain adjacent to the skull base was obtained without loss of detail due to partial-volume effect from bone. The saturation-recovery images highlighted arteries and veins that were clearly visible without the use of contrast agents. The inversion-recovery images showed remarkable gray-white matter differentiation enabling internal structure to be seen within the brainstem and cerebellum. The trigeminal nerve and ganglion were also seen outside the brain. Experience with the spin-echo technique is limited, but the images at the base of the brain show considerable soft-tissue detail. The NMR images of the posterior fossa in this study were comparable in quality to those obtained from a new rotate-rotate x-ray computed tomography machine and were superior in several respects.

Adult↗