PubMed Health⌕ Search

Biomedical subjects

D Teitz

Publications and source records attributed to D Teitz.

4 recordsLinked to original sources

Comparison of plasma sample purification by manual liquid-liquid extraction, automated 96-well liquid-liquid extraction and automated 96-well solid-phase extraction for analysis by high-performance liquid chromatography with tandem mass spectrometry.

Three extraction procedures were developed for the quantitative determination of a carboxylic acid containing analyte (I) in human plasma by high-performance liquid chromatography (HPLC) with negative ion electrospray tandem mass spectrometry (MS-MS). The first procedure was based on the manual liquid-liquid extraction (LLE) of the acidified plasma samples with methyl tert.-butyl ether. The second procedure was based on the automation of the manual LLE procedure using 96-well collection plates and a robotic liquid handling system. The third approach was based on automated solid-phase extraction (SPE) using 96-well SPE plates and a robotic liquid handling system. A lower limit of quantitation of 50 pg/ml was achieved using all three extraction procedures. The total time required to prepare calibration curve standards, aliquot the standards and plasma samples, and process a total of 96 standards and samples by manual LLE was three-times longer than the time required for 96-well SPE or 96-well LLE (4 h, 50 min vs. 1 h, 43 min). Even more importantly, the time the bioanalyst physically spent on the 96-well LLE or 96-well SPE procedure was only a small fraction of the time spent on the manual LLE procedure (<10 min vs. 4 h, 10 min). It should be noted that the 96-well SPE procedure incorporated the two steps of evaporation of the eluates to dryness and subsequent reconstitution of the dried extract. The total time required for the 96-well SPE could be reduced by 50% if the eluates were injected directly, eliminating the drying and reconstitution steps, which is achievable when sensitivity is less of an issue.

Automation↗

Quantitation of the acid and lactone forms of atorvastatin and its biotransformation products in human serum by high-performance liquid chromatography with electrospray tandem mass spectrometry.

A method for simultaneous quantitation of both the acid and lactone forms of atorvastatin, a new synthetic inhibitor of HMG-CoA reductase that is being marketed for the treatment of high serum cholesterol, and both the acid and lactone forms of its two biotransformation products, 2-hydroxyatorvastatin and 4-hydroxyatorvastatin, in human serum (a total of six analytes) by high-performance liquid chromatography with electrospray tandem mass spectrometry was developed and validated. A deuterium labeled analog was used as internal standard for each of the six analytes. Each point of the calibration standard curve, which ranged from 0.5 to 200 ng/mL, contained the six analytes at equal concentrations. Three groups of quality control (QC) samples were used. In the first group, combination QC samples contained all six analytes at equal concentrations. In the second group, acid-only QC samples contained only the acid forms (i.e. three analytes) at equal concentrations. In the third group, lactone-only QC samples contained only the lactone forms (i.e. three analytes) at equal concentrations. After adding the internal standard to 0.5 mL of each standard and the QC sample kept at 4 degrees C, the samples were acidified with sodium acetate buffer (pH 5.0) and then extracted with methyl tert-butyl ether. Detection was by positive ion electrospray tandem mass spectrometry using eight selected reaction monitoring channels. The acid compounds were stable in human serum at room temperature but the lactone compounds were unstable as they hydrolyzed rapidly to their respective acid forms. The conversion of the lactone compounds in both QC and post-dose human serum samples was nearly complete after 24 h at room temperature. The lactone compounds in serum could be stabilized by lowering the working temperature to 4 degrees C or lowering the serum pH to 6.0. The acid-only and the lactone-only QC samples showed that, under the sample processing conditions used, the degree of the hydrolysis of the lactone compounds or the lactonization of the acid compounds during the assay procedure was minimal (< 5%). The intra-day C.V., inter-day C.V. and the deviations from the nominal concentrations for all six analytes were within 15%, demonstrating good precision and accuracy. The required lower limit of quantitation (LLQ) of 0.5 ng/mL was achieved for each analyte.

Acids↗

Negative ion electrospray high-performance liquid chromatography-mass spectrometry method development for determination of a highly polar phosphonic acid/sulfonic acid compound in plasma. Optimization of ammonium acetate concentration and in-source collision-induced dissociation.

A method, based on negative ion electrospray ionization (ESI) single-stage mass spectrometry coupled with HPLC, was developed for the determination of a squalene synthase inhibitor, BMS-187745, in human plasma. BMS-187745, a highly polar compound with both phosphonic acid and sulfonic acid groups, presented difficulties in developing plasma extraction and HPLC procedures. Precipitation of the plasma protein with methanol was finally chosen as the basis for sample preparation since extraction with water-immiscible solvents or with solid-phase extraction columns failed. It was essential to add ammonium acetate to the HPLC mobile phase, not only to enhance the retention of BMS-187745 but also to ensure a well-shaped chromatographic peak. While the use of ammonium acetate had the desired chromatographic effects, it had the undesirable consequence of suppressing the negative ion ESI signal. With the plasma extracts, the [M-H2O-H]- ion (m/z 367) showed significantly lower chemical noise than the [M-H]- ion (m/z 385), and was thus chosen as the analytical ion for the selected ion monitoring. The signal of the m/z 367 ion was significantly enhanced by the optimization of the in-source collision-induced dissociation (CID) of m/z 385 to m/z 367.

Acetates↗

Simultaneous determination of the prodrug zofenopril and its active drug in plasma by capillary gas chromatography-mass-selective detection.

After oral administration of zofenopril, the active sulfhydryl angiotensin-converting enzyme inhibitor is released. Zofenopril is currently under clinical investigation as an antihypertensive. Blood samples are reacted with N-ethylmaleimide, immediately after collection, processed into plasma and stored frozen for subsequent analysis. After addition of two internal reference standards, one each for the prodrug and the active compound, the plasma samples are purified by a combination of liquid-liquid and solid-phase extractions. The dried methylated extracts are reconstituted with tetramethylbenzene and chromatographed by automated splitless injection on a fused-silica capillary column, connected to a mass-selective detector. The analytes and the internal reference standards are chromatographically resolved and a common fragment ion is monitored for the analytes. A limit of quantitation of approximately 1 ng/ml of plasma is achieved.

Angiotensin-Converting Enzyme Inhibitors↗