Management of supraventricular tachycardia in septic patients.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to D Thangathurai.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The ability of a new continuous-wave Doppler esophageal probe to measure cardiac output noninvasively during surgery under general anesthesia was tested and compared with simultaneously measured thermodilution cardiac output. A Doppler computer, calibrated for the aortic diameter and the transcutaneously measured cardiac output from the suprasternal notch, computed the Doppler cardiac output from the descending aortic blood flow velocity signal. A total of 246 paired Doppler cardiac output and thermodilution cardiac output measurements were made in 14 patients during surgery. The average thermodilution cardiac output was 5.90 +/- 3.27 (standard deviation) liters/min (range 1.20 to 19.18); the average Doppler cardiac output was 6.21 +/- 4.0 liters/min (range 2.30 to 28.20). The difference between the cardiac output measured by the 2 techniques was 1.38 +/- 2.2 liters/min (range 0.04 to 16.8). Two to 5 cardiac output measurements were averaged and arranged into "time periods." The average standard deviations for thermodilution and Doppler cardiac outputs within each time period were 0.64 and 0.47 liters/min, respectively. There was a correlation between the 2 measurements over a range of cardiac output values (r = 0.76, Doppler cardiac output = 0.93 x thermodilution cardiac output +0.7, standard error of the estimate = 1.76). Reproducible measurements of Doppler cardiac output were obtained during intraobserver (mean difference 0.64 +/- 0.52 liter/min) and interobserver (mean difference 0.41 +/- 0.36 liter/min) studies (n = 8). Cardiac output measurement by the Doppler esophageal probe could be used for hemodynamic monitoring during surgery in selected patients with cardiopulmonary disease.
The use of intravenous papaverine as an adjunct in the construction of a continent urinary reservoir is a safe and effective method to facilitate an important but sometimes restrictive portion of this procedure. Additionally, it does not seem unreasonable to extend this technique to other procedures which involve the use of small bowel.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Cardiac arrest while straining during a bowel movement is not unusual in elderly patients. Sinus bradycardia caused by increased vagal tone can lead to severe myocardial and cerebral hypoperfusion with cardiac arrest. We describe a female postoperative patient who, while straining on a bedside commode, developed varying degrees of atrioventricular heart block, necessitating placement of a permanent pacemaker.
Twenty adult patients were monitored with a transcutaneous oxygen tension sensor during one-lung ventilation. Anesthesia was maintained with enflurane-oxygen or isoflurane-oxygen. The transcutaneous oxygen tension values accurately followed the trend of arterial oxygen tension (r = 0.94, n = 96, transcutaneous oxygen tension = 4.8 + 0.78 X arterial oxygen tension). The transcutaneous oxygen tension values averaged 80% of the arterial oxygen tension values (transcutaneous oxygen tension index = transcutaneous oxygen tension/arterial oxygen tension = 0.80 +/- 0.18) (mean +/- standard deviation). When one-lung ventilation was initiated, there was a progressive drop in transcutaneous oxygen tension which reached a minimum of 19 +/- 10 minutes. The mean of the minimum transcutaneous oxygen tension and arterial oxygen tension values was 66 +/- 44 torr and 83 +/- 43 respectively. This resulted in a mean alveolar-arterial oxygen gradient of 515 +/- 152 torr during one-lung ventilation. In eight patients, the arterial oxygen tension fell below 60 torr, 45 +/- 9 torr. When two-lung ventilation was resumed, the transcutaneous oxygen tension and arterial oxygen tension values promptly rose to mean values of 342 +/- 121 torr and 411 +/- 103 torr, respectively in 9 +/- 3 minutes. The transcutaneous oxygen tension monitor provided a continuous assessment of the patient's oxygenation, gave early warning of potentially hazardous hypoxia, and permitted nearly real-time assessment of the efficacy of corrective therapies.
Explore the source record for details and available documents.
When a young man with terminal cancer requested return to his native country to spend the remainder of his life with family and friends, the medical team assigned to take him home learned firsthand the challenges of caring for a ventilator-dependent patient during a long international flight on a commercial aircraft.