Controller for an axial flow blood pump.

A rotary blood pump inherently provides only one noninvasive "observable" parameter (motor current) and allows for only one "controllable" parameter (pump speed.) To maintain the systemic circulation properly, the pump seed must be controlled to sustain appropriate outlet flows and perfusion pressure while preventing pulmonary damage caused by extremes in preload. Steady-state data were collected at repeated intervals during chronic trials of the Nimbus AxiPump (Nimbus, Inc., Rancho Cordova, California, U.S.A.) in sheep (n = 7) and calves (n = 12). For each data set, the pump speed was increased at increments of 500 rpm until left ventricular and left atrial emptying was observed by left atrial pressure diminishing to zero. The effect of decreasing preload was evaluated perioperatively by inferior vena cava occlusion at a constant pump speed. Fourier analysis established a relationship between changes in the pump preload and the power spectra of the pump current waveform. Based on these results, a control method was devised to avoid ventricular collapse and maintain the preload within a physiologic range. The objective of this controller is the minimization of the second and third harmonic of the periodic current waveform. This method is intended to provide a noninvasive regulation of the pump by eliminating the need for extraneous transducers.

Animals↗

Induction of ventricular collapse by an axial flow blood pump.

An important consideration for clinical application of rotary blood pump based ventricular assist is the avoidance of ventricular collapse due to excessive operating speed. Because healthy animals do not typically demonstrate this phenomenon, it is difficult to evaluate control algorithms for avoiding suction in vivo. An acute hemodynamic study was thus conducted to determine the conditions under which suction could be induced. A 70 kg calf was implanted with an axial flow assist device (Nimbus/UoP IVAS; Nimbus Inc., Rancho Cordova, CA) cannulated from the left ventricular apex to ascending aorta. On initiation of pump operation, several vasoactive interventions were performed to alter preload, afterload, and contractility of the left ventricle. Initially, dobutamine increased contractility and heart rate ([HR] = 139; baseline = 70), but ventricular collapse was not achievable, even at the maximal pump speed of 15,000 rpm. Norepinephrine decreased HR (HR = 60), increased contractility, and increased systemic vascular resistance ([SVR] = 24; baseline = 15), resulting in ventricular collapse at a pump speed of 14,000 rpm. Isoproterenol (beta agonist) increased HR (HR = 103) and decreased SVR (SVR = 12), but ventricular collapse was not achieved. Inferior vena cava occlusion reduced preload, and ventricular collapse was achieved at speeds as low as 11,000 rpm. Esmolol (beta1 antagonist) decreased HR (HR = 55) and contractility, and ventricular collapse was achieved at 11,500 rpm. Episodes of ventricular collapse were characterized initially by the pump output exceeding the venous return and the aortic valve remaining closed throughout the cardiac cycle. If continued, the mitral valve would remain open throughout the cardiac cycle. Using these unique states of the mitral and aortic valves, the onset of ventricular collapse could reliably be identified. It is hoped that the ability to detect the onset of ventricular collapse, rather than the event itself, will assist in the development and the evaluation of control algorithms for rotary ventricular assist devices.

Adrenergic alpha-Agonists↗

Antagonism of calcium-induced contractions by some non-specific spasmolytics in depolarized smooth muscles.

The effects of papaverine MgCl2, cocaine, DNP, KCN and khellin on responses of some rabbit and rat tissues to CaCl2 were studied in vitro in a depolarizing medium. Guinea pig taenia coli preparation was used for comparison. In rabbit tracheal chain and vas deferens and guinea pig taenia coli preparations all spasmolytics shifted the concentration-response curves of CaCl2 to the right without affecting the maxima or slopes. In rat tracheal chain and vas deferens preparations all spasmolytics shifted the concentration-response curves of CaCl2 to the right. Furthermore all agents (except cocaine in tracheal chain preparations) depressed the maximum responses. The slopes were unaffected in either preparations. The initial competition and subsequent noncompetition observed in certain tissues is discussed in the light of the reported poor capacity of some tissues to retain Ca++ and the absence of releasable firmly bound Ca++ (11).

Animals↗

Controller for an axial-flow blood pump.

An axial-flow ventricular assist device (VAD) under development at the authors' facility is intended for use as a long-term implantable device. At high speeds axial-flow VADs can collapse the native ventricle and damage the heart muscle, lung tissue, and blood. A prototype algorithm was developed to maintain physiologic perfusion to the vital organs while preventing ventricular collapse, through analysis of the electrical current waveform of the motor. The premise of the control algorithm is that the hemodynamics of the patient are reflected in the shape of this waveform. This approach is intended to eliminate the need for invasive sensors, thus effectively using the pump itself as a transducer. The control algorithm regulates the speed of the pump by comparing the motor-current waveform with reference waveforms using a matched filter. The matched filter was evaluated by its classification and differentiation performance. Thus far, the authors have been able to classify the waveforms into one of the four physiologic regions (below, within, or above the optimal range, and ventricular suction) with over 90% reliability. Ongoing work is directed toward improving the detection of ventricular suction, as this condition must be strictly avoided.

Algorithms↗