PubMed Health⌕ Search

Biomedical subjects

D Valdarnini

Publications and source records attributed to D Valdarnini.

3 recordsLinked to original sources

Modulation by ST 789 of in vitro lymphocyte activation and cytokine production.

Our results indicate that ST 789 exhibits complex immunomodulant properties. In fact, we found that ST 789 inhibits the expression of activation antigens, such as interleukin-2 and transferrin receptors by peripheral blood mononuclear cells (PBMCs) from healthy subjects following mitogen stimulation, but we were not able to detect under the same experimental conditions any effect on the in vitro production of soluble CD8 antigen and of interleukin-4 as well as on the proliferative response of antigen-specific and autoreactive human T cell lines. Finally, we showed that ST 789 is able to strongly enhance the in vitro production of interleukin-6 by PHA-stimulated PBMCs. The reduced expression of activation antigens in the presence of ST 789 does not seem to be mediated by CD8+ suppressor T lymphocytes, as indicated by the normal soluble CD8 levels in culture media, but rather reflects a direct inhibitory action on T helper proliferation and likely on interleukin-2 secretion. The strong enhancement by ST 789 of the in vitro interleukin-6 production seems to indicate the most relevant possibility of clinical applications in human diseases.

Adjuvants, Immunologic↗

[Colostomy control using an original occluding device. A clinico-experimental study].

After having examined different methods as to continence colostomy, the authors introduce their own control system for the stoma. The study was carried out on 6 colostomized patients. Preliminary, the intraluminal pressure in closed colostomy was recorded. Pressure waves, largely varying from patient to patient, were obtained as to frequency of waves and pressure values. The same variations were observed during meals waking and sleeping. Sometimes the patients suffered from serious disorder, but in most cases they did not feel pain. A catheter, provided with an inflatable balloon for closing the stoma, formed the system tested. It was also provided with a second intraluminal low-pressure inflated balloon, connected with an external compensating chamber. As a result of the system the pressure dropped down to about 1/6 compared with the reference values observed under the same conditions. In addition, the continence was complete and the patient did not suffer from any disorder in non-stop recordings up to 24 hours. We believe that the system may be useful for colostomized patients if carefully carried out.

Colostomy↗