On-line portal imaging: image quality defining parameters for pelvic fields--a clinical evaluation.

PURPOSE: A test of several image enhancement techniques, performed on on-line portal images in real clinical circumstances, is presented. In addition a score system enabling us to evaluate image quality on pelvic fields is proposed and validated. METHODS AND MATERIALS: Localization images (n = 546) generated by an on-line portal imaging system during the treatment of 13 patients on pelvic fields were obtained by delivering a radiation dose of 6-8 cGy by an 18 MV photon beam, and recorded with a silicon intensified target video camera with adjustable gain, kV- and black level. Set-up errors were corrected before continuing irradiation. A scoring system based on the number of visible bone-soft tissue edges and transformed to a scale 0 to 5 was developed to judge image quality. A validation of this classification of images was performed with the use of transsectional bone-densities (bone-density*radiological path length) specified at the score defining landmarks. A high pass filter was used on all images, additional on-line open field subtraction was performed on 242 fields. Off-line study was performed in which a panel consisting of two groups (one composed of three radiation oncologists, the other of three radiotherapy technologists), scored 470 pelvic fields without further enhancement, and the same images with Contrast Limited Adaptive Histogram Equalization (CLAHE) (Pizer et al.). Two different clipping levels (3.0 and 5.0) were studied. RESULTS: Gender and transsectional bone-densities were the most defining patient-related factors influencing image quality. Camera settings, gantry angle, and image post-processing were important non-patient-related factors. All investigators judged CLAHE to ameliorate low contrast images and to deteriorate good quality images (p < 0.001).

Humans↗

Interactive use of on-line portal imaging in pelvic radiation.

We have evaluated a fluoroscopic on-line portal imaging system in routine clinical radiotherapy, involving the treatment of 566 pelvic fields on 13 patients. The image was typically generated by delivering a radiation dose of 6-8 cGy. Comparison between portal image and simulator film was done by eye and all visible errors were corrected before continuing irradiation. If possible, these corrections were performed from outside the treatment room by moving the patient couch by remote control or by changing collimator parameters. Adjustments were performed on 289/530 (54.5%) evaluable fields or 229/278 (82.4%) evaluable patient set-ups. The lateral couch position was most frequently adjusted (n = 254). The absolute values of the adjustments were 6.8 mm mean (SD 6.6 mm) with a maximum of 40 mm. All absolute values of adjustments exceeding 25 mm were recorded in one patient and those exceeding 15 mm were observed in two patients. Both patients were obese females. Adjustments exceeding 5 mm were observed in all 13 patients. Related to the use of on-line portal imaging, treatment time was increased by a median of 36.5% (mean 45.8%; SD 42.1%). The range was 7.7 to 442%. The fraction of the total treatment time to perform corrections was 22.7% median (mean: 26.0; SD: 11.8%). Statistically significant systematic in-plane errors were found in 7/13 patients. A systematic error was detected on the lateral position of the field in five patients. In one patient a systematic error of the longitudinal field position and in one patient a rotational error was detected. For adjustments in the lateral direction the present method does not allow to detect lateral shifts of less than 2 mm. For adjustments in the longitudinal direction the sensitivity could not be estimated but the available data suggest that 80% of errors < or = 5 mm were not adjusted. In obese patients, random errors may be surprisingly large.

Evaluation Studies as Topic↗

[Conformal radiotherapy: tomotherapy].

Conformal radiation therapy allows the possibility of delivering high doses at the tumor volume whilst limiting the dose to the surrounding tissues and diminishing the secondary effects. With the example of the conformal radiation therapy used at the AZ VUB (3DCRT and tomotherapy), two treatment plans of a left ethmoid carcinoma will be evaluated and discussed in detail. The treatment of ethmoid cancer is technically difficult for both radiation therapy and surgery because of the anatomic constraints and patterns of local spread. A radiation therapy is scheduled to be delivered after surgical resection of the tumor. The treatment plan for the radiation therapy was calculated on a three-dimensional (3D) treatment planning system based on virtual simulation with a beam's eye view: George Sherouse's Gratis. An effort was made to make the plan as conformal and as homogeneous as possible to deliver a dose of 66 Gy in 33 fractions at the tumor bed with a maximum dose of 56 Gy to the right optic nerve and the chiasma. To establish the clinical utility and potential advantages of tomotherapy over 3DCRT for ethmoid carcinoma, the treatment of this patient was also planned with Peacock Plan. For both treatment plans the isodose distributions and cumulative dose volume histograms (CDVH) were computed. Superimposing the CDVHs yielded similar curves for the target and an obvious improvement for organs at risk such as the chiasma, brainstem and the left eye when applying tomotherapy. These results have also been reflected in the tumor control probabilities (equal for both plans) and the normal tissue complication probabilities (NTCP), yielded significant reductions in NTCP for tomotherapy. The probability of uncomplicated tumor control was 52.7% for tomotherapy against 38.3% for 3DCRT.

Ethmoid Bone↗