PubMed Health⌕ Search

Biomedical subjects

D Villalta

Publications and source records attributed to D Villalta.

At least 19 recordsLinked to original sources

The role of antitissue transglutaminase assay for the diagnosis and monitoring of coeliac disease: a French-Italian multicentre study.

AIMS: Tissue transglutaminase (tTG) was recently identified as the major autoantigen in coeliac disease. The aim of this multicentre study was to evaluate the impact of a new immunoenzymatic assay for the detection of IgA anti-tGT antibodies. METHODS: Seventy four Italian and French clinical laboratories participated in this study; anti-tTG IgA with an enzyme linked immunosorbent assay (ELISA) method using guinea pig liver extract as the coating antigen, anti-endomysium IgA autoantibodies (EMA), and total serum IgA were determined in 7948 patients, 1162 of whom had coeliac disease (737 untreated cases and 425 on a gluten free diet). A proportion of the sera were then sent to a reference laboratory for anti-tTG retesting with an ELISA method using recombinant human tTG antigen. RESULTS: Seven thousand four hundred and fifty eight (93.8%) sera were EMA/antiguinea pig tTG concordant (positive or negative); 490 (6.2%) were non-concordant. The sensitivity of EMA and antiguinea pig tTG in the 737 untreated patients with coeliac disease was 92.1% and 94.8%, respectively, and the specificity was 99.8% and 99.2%, respectively. Retesting of the discordant sera showed that of the 162 sera classified as EMA negative/antiguinea pig tTG positive, only 49 were positive for human recombinant anti-tTG, and that 39 of these were also EMA positive. Furthermore, of the 36 sera classified as EMA positive/antiguinea pig tTG negative, only two were confirmed as EMA positive. CONCLUSIONS: The antiguinea pig tTG assay is more sensitive but less specific than EMA, whereas the antihuman recombinant tTG assay is far more specific and just as sensitive as antiguinea pig tTG. Testing for EMA presents considerable interpretative problems and is difficult to standardise.

Adolescent↗

Anti-dsDNA antibody avidity determination by a simple reliable ELISA method for SLE diagnosis and monitoring.

High avidity anti-dsDNA antibodies are more specific for SLE diagnosis, and more closely associated with renal involvement than intermediate or low-affinity anti-dsDNA antibodies. ELISA methods are largely used to detect anti-dsDNA, but their high sensitivity is inversely related to specificity because they also detect low avidity antibodies. We developed an ELISA assay based on the law of mass action and the competitive binding of dsDNA in solution and coated to microwells with anti-dsDNA antibodies. A simplified Scatchard plot analysis system was used to measure anti-dsDNA antibody avidity which was expressed as apparent affinity constant (Kaa), and quantified in liters per unit (I/U). We prospectively studied 101 consecutive SLE patients, who were followed for 3 years; three serum samples were sequentially collected from each patient during follow-up for determination of IgG anti-dsDNA antibody concentration, and anti-dsDNA avidity. SLE disease activity was estimated using the European Consensus Lupus Activity Measure (ECLAM) index. Sera from 100 healthy subjects and 133 patients with other connective tissue diseases or infectious diseases were also assayed as controls. The mean Kaa in SLE patients was 65.2 +/- 47.3 l/U, with no variations over time. Anti-dsDNA-positive SLE patients had higher Kaa values (79.1 +/- 46.8) than anti-dsDNA negative patients (27.2 +/- 20.1; P < 0.001). No correlation emerged between anti-dsDNA avidity and the ECLAM activity index score. Avidity was significantly higher in patients with renal involvement vs patients without this complication (78.2 +/- 50 vs 59.9 +/- 45.6 l/U; P = 0.0013). This simple ELISA method could be very useful in the diagnostic phase to differentiate high avidity anti-dsDNA autoantibodies that are characteristically found in SLE patients from low avidity antibodies that can also be found in other inflammatory diseases. Moreover, our data confirm the predictive value of high avidity anti-dsDNA antibodies for the development of lupus nephritis.

Adult↗

Evaluation of a new automated enzyme fluoroimmunoassay using recombinant plasmid dsDNA for the detection of anti-dsDNA antibodies in SLE.

ELISA methods to detect anti-double-stranded DNA (anti-dsDNA) antibodies are highly sensitive, but are less specific for the diagnosis of SLE than the immunofluorescence test on Crithidia luciliae (CLIFT) and the Farr assay because they also detect low-avidity antibodies. This study evaluated the specificity, sensitivity, positive predictive value (PPV), and negative predictive value (NPV) of a new automated fluoroimmunoassay (EliA dsDNA; Pharmacia, Freiburg, Germany). We compared the results with those obtained using a commercial CLIFT and an in-house anti-dsDNA IgG ELISA method, and verified its putative ability to detect only high-avidity anti-dsDNA antibodies. Sera from 100 SLE patients and 120 controls were studied. The control group included 20 healthy donors, 70 patients with other rheumatic diseases (32 systemic sclerosis (SSc); 18 primary Sjögren syndrome (pSS), 20 rheumatoid arthritis (RA)), and 30 patients with various infectious diseases (ID). Anti-dsDNA avidity was estimated using an ELISA method based upon the law of mass action, and a simplified Scatchard plot analysis for data elaboration; the apparent affinity constant (Kaa) was calculated and expressed as arbitrary units (L/U). Sensitivity, specificity, PPV, and NPV for SLE were 64%, 95.8%, 93.8% and 72.7%, respectively, for the EliA anti-dsDNA assay; 55%, 99.2%, 98.5%, and 68.8%, respectively, for the CLIFT; and 64%, 93.3%, 90.6%, and 72.3%, respectively, for the in-house ELISA. Although EliA anti-dsDNA was positive mainly in SLE patients with high- (Kaa>80 L/U) and intermediate- (Kaa 30-80 L/U) avidity antibodies (45.3% and 49.9%, respectively), it was also positive in five (7.8%) SLE patients with low-avidity anti-dsDNA antibodies, and five controls (three SSc, one pSS, and one ID) (mean Kaa = 16.4 +/- 9.04 L/U). In conclusion, EliA anti-dsDNA assay showed a higher sensitivity than the CLIFT, and a good specificity and PPV for SLE. Its putative ability to detect only high-avidity anti-dsDNA antibodies remains questionable.

Adult↗

New coupled-particle light-scattering assay for detection of Ro/SSA (52 and 60 kilodaltons) and La/SSB autoantibodies in connective tissue diseases.

The diagnostic and analytical performance of the coupled-particle light-scattering assay in detecting anti-Ro/SSA autoantibodies (the 60-kDa [Ro60] and the 52-kDa [Ro52] antibodies) and anti-La/SSB autoantibodies was evaluated. The antigens were obtained by recombinant DNA procedures to include the most immunogenic epitopes for each protein by using a prokaryotic expression system. Serum samples from 151 patients with connective tissue diseases and 52 control subjects (including patients with viral infections, patients with Lyme disease, and healthy subjects) were studied. Sensitivities for detection of anti-Ro/SSA and anti-La/SSB were 88.2 and 95.2%, respectively; specificities were 97.6 and 98.1%, respectively. The intra-assay coefficient of variation (CV) ranged from 4.3 to 10.9% for anti-Ro/SSA and from 2.8 to 12.5% for anti-La/SSB; interassay CVs ranged from 6.5 to 13.2% and from 8.2 to 14.5%, respectively. Among the anti-Ro/SSA-positive samples, Ro60 was recognized by 66% of the test sera and Ro52 was recognized by 95% of the test sera. Thirty-four percent of the Ro/SSA-positive sera were reactive only with the Ro52 antigen, indicating that anti-Ro52 is the most common antibody specificity recognized by anti-Ro/SSA autoantibodies. No differences were found between the prevalences of anti-Ro60 and anti-Ro52 in relation to systemic lupus erythematosus or Sjögren's syndrome. The results of the present study indicate that this new immunoassay is an efficient diagnostic tool for the detection of anti-Ro/SSA and anti-La/SSB antibodies in patients with autoimmune disorders.

Antibodies, Antinuclear↗

Diagnostic accuracy of the anti-citrulline antibody assay for rheumatoid arthritis.

BACKGROUND: Rheumatoid arthritis (RA) is the most common autoimmune rheumatic disease, but specific and practicable tests for its diagnosis are lacking. We evaluated the diagnostic accuracy of a new commercial ELISA in detecting anti-cyclic citrullinated peptide (CCP) antibodies for the diagnosis of RA. METHODS: Anti-CCP antibodies were determined in 330 serum samples: 98 from RA patients and 232 from controls, including patients with connective tissue diseases, other rheumatic diseases, viral infections, Lyme disease, autoimmune thyroiditis, cancer, and monoclonal gammopathy, and sex- and age-matched healthy subjects. Intra- and interassay CVs were 5-13% and 9-17%, respectively. Rheumatoid factor (RF) was also assayed in every sample, and results were compared to anti-CCP for sensitivity and specificity. RESULTS: At a cutoff value of 50 units, sensitivity was 41% (confidence interval, 31-50%) and specificity was 97.8% (95-100%). Anti-CCP-positive RA patients had a mean antibody concentration of 1100 units (range, 57-3419 units), and anti-CCP-negative RA patients and controls had mean values of 7.6 and 6.8 units, respectively (range, 1-39 units). The area under the ROC curve was 0.71 (95% confidence interval, 0.63-0.78). RF had a higher sensitivity (62%) and a lower specificity (84%) than anti-CCP. When the two antibodies were used together, specificity was 99.6%. CONCLUSION: Anti-CCP antibody testing may be useful if performed concomitantly with RF assay to diagnose patients with suspected early RA.

Adult↗

[Laboratory diagnosis of autoimmune thyroid disease].

Assay of the anti-thyroperoxidase (TPO), anti-thyroglobulin (Tg), and anti-TSH receptor antibodies constitutes the basis of the laboratory diagnostic work-up for autoimmune thyroid diseases. However, although these antibodies have been routinely assayed in serum for more than 40 years with increasingly reliable methods, it still exists a wide analytical variability that influences their correct diagnostic use. We analysed the biochemical, physiopathological and clinical aspects of the thyroid antigen-anti body systems, and propose the following guidelines for using autoantibody tests and analytical assay methods: a) assay of anti-TPO with third generation ultrasensitive method should constitute the main test for the diagnosis of autoimmune thyroid diseases. Assay of anti-M antibodies should be considered obsolete because even purified microsome preparations contain traces of contaminants (Tg and other antigens) that make the test aspecific; b) assay of anti-Tg antibodies may be limited to patients with suspect AITD and negative for anti-TPO antibodies, and patients undergoing thyroglobulin assay, because anti-Tg autoantibodies may interfere in the assay of the molecule in the immunometric test; c) assay of the anti-TSH receptor antibodies is used to diagnose Basedow's disease, and atrophic chronic thyroiditis; d) it is appropriate to use normal reference values adjusted for age and gender.

Antigen-Antibody Reactions↗

Sensitivity and specificity of immunological methods for the detection of anti-topoisomerase I (Scl70) autoantibodies: results of a multicenter study. The Italian Society of Laboratory Medicine Study Group on the Diagnosis of Autoimmune diseases.

BACKGROUND: The ability of immunometric methods to identify anti-topoisomerase I (Scl70) antibodies is controversial. We wished to quantify the performance of the currently available commercial systems for the assay of anti-topoisomerase I antibodies in a large multicenter study. METHODS: Fifty Italian clinical laboratories analyzed 36 serum samples: 27 from individuals with scleroderma/systemic sclerosis, and 9 from a control group. The scleroderma/systemic sclerosis samples were positive in our laboratories by both ELISA and immunoblot (IB), and the control samples were negative. The laboratories used 42 immunoenzymatic (ELISA), 21 IB, 3 counterimmunoelectrophoresis, and 2 dot-blot methods, produced by 23 different manufacturers. RESULTS: We obtained 2389 results. The ELISA methods showed 99.2% specificity and 97.2% sensitivity for detection of anti-Scl70 antibodies. For IB methods, specificity was 97.6% and sensitivity was 96.1%. The Western-blot method had poor analytical specificity (27% false positives for anti-extractable nuclear antigen antibodies other than anti-Scl70). CONCLUSIONS: Excluding Western blots, commercial ELISA and IB reagents as used in clinical laboratories have a sensitivity and a specificity >95% for determination of anti-Scl70 antibodies.

Autoantibodies↗

Automatic capture verification by charge-neutral sensing.

Automatic capture verification can prolong pulse generator longevity and increase patient safety. However, the detection of evoked response following pacing is complicated due to afterpotentials caused by polarization of electrodes. This study describes a new capture verification scheme, which neutralizes the charges between the pacing electrodes. The hypothesis of the charge-neutral sensing is that the afterpotentials in the ring and the tip are opposite in polarity when pacing in a bipolar mode between ring and tip. Summing the unipolar signals sensed at the tip and the ring should effectively cancel the afterpotentials. This scheme was implemented in an external computer based system and tested during pacemaker implant/replacement on 23 patients during VVI pacing (17 acutely implanted leads and 6 chronic leads). Surface ECG was recorded to provide a marker for capture and noncapture. The pacing voltage was gradually decreased until a noncapture beat was noted. To avoid fusion beats, the pacing rate was programmed approximately 50% higher than the intrinsic rate. The evoked response was high pass filtered and the integral average was calculated for both capture and noncapture beats. The system signal to noise ratio (SNR) was expressed as ratio of the minimum integral average of all capture beats to the maximum integral average of all noncapture beats. The system SNR was 8.6 +/- 1.3 (mean +/- S.E.M; range 1.5-22.8), indicating that the charge-neutral sensing method has, on average, a ninefold safety margin in providing capture verification. Further, evaluation is needed to fully assess this feature in patients with chronic leads.

Aged↗

[Detection of anti-ENA autoantibodies in patients with systemic connective tissue diseases. Analytical variability and diagnostic sensitivity of 4 methods].

This study was designed to assess the analytical sensitivity and rate of agreement between commercial methods and reagents, among the most used in Italy for the detection of autoantibodies to extractable nuclear antigens (ENA). Sixty-eight serum samples from patients with clinically diagnosed systemic rheumatic diseases were aliquoted and distributed to 4 hospital laboratories; three ELISA (Elias, Shield, Inova) and 1 immunoblot method (Euroimmun) were used. Overall agreement between the test reagents, for each anti-ENA specificity, was 69.1% for Ro/SSA, 83.3% for La/SSB, 70.6% for RNP, 73.5% for Sm, 91.1% for Jo1, and 82.3% for Scl70. Lack of specificity (i.e., false positive reactions) was the most important cause of low concordance. When the data were analysed according to the clinical diagnosis, total agreement and specificity improved. However, a significant difference in terms of sensitivity was observed in the SLE group (30 sera) for RNP (positivity ranged from 20% to 43%) and for Sm (from 7% to 37%), and in the Sjögren's syndrome group (13 sera) for anti-La/SSB (from 8% to 38%). Comparable data were obtained for anti-Ro/SSA (from 70% to 77%) both in the SLE and the Sjögren's syndrome group. Sensitivity of all 4 reagents was good in detecting anti-Scl70 autoantibodies in the 8 patients with diffuse systemic sclerosis, as well as anti-Jo1 autoantibody in the 5 polymyositis patients, with a 100% and a 95% agreement, respectively. These data suggest the need of a better standardization of commercial reagents and analytical procedures, and the opportunity that every laboratory should perform anti-ENA determination by at least two different methods, since none of the methods tested was completely reliable in detecting all anti-ENA autoantibody specificities.

Antibodies, Antinuclear↗

Variability between methods to determine ANA, anti-dsDNA and anti-ENA autoantibodies: a collaborative study with the biomedical industry.

This study was performed by the Italian Society of Laboratory Medicine (SIMeL) in order to establish the variability between the different analytical systems currently used in clinical laboratories for the detection of autoantibodies diagnostic of systemic autoimmune disease. Sixteen industrial, and two university laboratories participated in this study which entailed the determination of anti-nuclear (ANA), anti-dsDNA and anti-ENA antibodies in 11 sera from patients with clinically diagnosed systemic rheumatic disease, using reagents produced by these companies and different methodologies (indirect immunofluorescence, immunoenzymatic assay, counterimmunolectrophoresis, immuno and western blotting). We found 93.5% agreement between the methods used for the detection of ANA, 85.2% for anti-dsDNA antibodies, and 86.9% for anti-ENA antibodies. Among the anti-ENA antibodies, regardless of the method used, detection percentages were excellent for anti-RNP and anti-SSB/La (100%), good for anti-SSA/Ro (93%), but unacceptable for the anti-Jo-1 (67%), anti-Scl70 and anti-Sm (47%) antibodies. This further stresses the need for rigorous standardisation of commercial reagents and analytical procedures, as well as the introduction of external quality assessment (EQA) programs, and a complete definition of operative protocols adjusted to the sensitivity and specificity of the various methods.

Antibodies, Antinuclear↗

Relief of pruritus and decreases in plasma histamine concentrations during erythropoietin therapy in patients with uremia.

BACKGROUND: The pathophysiologic aspects of pruritus in patients with chronic renal insufficiency are poorly understood, and there is no universally effective treatment. The improvement of pruritus in several patients receiving erythropoietin therapy raised the possibility that erythropoietin affects uremic pruritus directly. METHODS: We undertook a 10-week placebo-controlled, double-blind, crossover study in a group of patients receiving hemodialysis who had severe pruritus, to investigate the effects of recombinant human erythropoietin on their pruritus and plasma histamine levels. Twenty patients with uremia, of whom 10 had severe pruritus and 10 did not, received erythropoietin (36 units per kilogram of body weight three times weekly) and placebo in random order, each for five weeks. The severity of pruritus was scored weekly, and plasma histamine levels were measured at the beginning and end of each five-week period. RESULTS: Eight of the 10 patients with pruritus had marked reductions in their pruritus scores during erythropoietin therapy. The mean (+/- SE) pruritus score decreased from 25 +/- 3 to 6 +/- 1 in these patients. The pruritus returned within one week after the discontinuation of therapy. The improvement was not related to the change in hemoglobin level. These eight patients were successfully treated again with low doses of erythropoietin (18 units per kilogram three times weekly), and the effect has persisted for six months. The patients with pruritus had elevated plasma histamine concentrations (20.7 +/- 2.7 nmol per liter), as compared with the patients without pruritus (4.2 +/- 0.6 nmol per liter; P less than 0.001) and normal subjects (2.1 +/- 0.2 nmol per liter; P less than 0.001). Therapy with erythropoietin induced a decrease in plasma histamine concentrations in both groups of patients with uremia, and recurrences of pruritus after the discontinuation of erythropoietin were accompanied by increases in plasma histamine concentrations. CONCLUSIONS: Erythropoietin therapy lowers plasma histamine concentrations in patients with uremia and can result in marked improvement of pruritus.

Double-Blind Method↗

Evaluation of an automated commercial immunoluminometric assay for alpha-foetoprotein.

We evaluated a two-site immunoluminometric assay (AFP LIA-mat Byk Sangtec) for the determination of alpha-foetoprotein (AFP). The assay, involving two monoclonal antibodies which recognize two different alpha-foetoprotein epitopes, is rapid (4 h) with a wide working range (0-600 x 10(3) IU/l), a good lower limit of detection and good reproducibility (CV less than 10%). The regression equation for the AFP LIA-mat (y) and the immunoradiometric assay AFP Bridge Serono (x) was y = 1.175x - 2.27 (n = 95, r = 0.996) for serum and y = 1.16x + 479.2 for amniotic fluid. It did not display a hook effect, and when we assessed the linearity by assaying a high concentration of alpha-foetoprotein, it gave a linear response down to 3.1 x 10(3) IU/l. We also evaluated the clinical response of AFP LIA-mat in 278 patients with different diseases. Eighteen of the 19 patients with hepatocellular carcinoma had alpha-foetoprotein levels greater than 100 x 10(3) IU/l. In contrast, only 5 of the 47 patients with cirrhosis showed values above 50 x 10(3) IU/l, demonstrating that this assay discriminates fairly well between hepatocellular carcinoma and cirrhosis. Data in agreement with the literature were obtained for testicular tumours; all of seven seminomatous tumours presented values below 5 x 10(3) IU/l, whereas 50% of the non-seminomatous tumours (n = 8) presented values above 20 x 10(3) IU/l.

Autoanalysis↗

Time-related shape control modifications during erythrocyte storage with additive solutions.

To obtain more detailed information on the reversibility of shape alterations in blood bank stored erythrocytes, we have studied shape recovery after chemical crenation and rheological properties in 8 PAGGS-sorbitol preserved erythrocyte concentrates during a five week storage period under blood bank conditions. Our results show that red cell capability to regain a normal discoid shape after chemical crenation decreases during storage but is not lost over a five week period. Moreover there is a significant but weak correlation between red cell ATP content and both shape recovery capability and viscosity. Our results confirm suspicious that red cell shape perturbations following blood bank storage are widely reversible. Two different mechanisms may be involved in reducing shape recovery capability during storage, namely an ATP-dependent mechanism and an energy-independent one. The energy dependent mechanism may be preserved by the previous addition of solutions which maintain higher energy levels during storage.

Adenine↗

Critical evaluation of bioluminescence methods for quantifying bacterial adhesion to polystyrene.

A total of 134 strains of Escherichia coli which included 60 fecal and 74 urinary isolates, cultured in liquid and on solid media, were examined for adhesive properties using bioluminescence and haemagglutination methods. The study aimed to verify whether irrespective of the absence or presence of flagella, there is any relation between haemagglutination and bioluminescence test. Examining the results we failed to note any correlation between the two methods: strains bearing MS, MR or MS-MR adhesins adhered to polystyrene at random. Even though it is fast and easy to perform, bioluminescence is not an alternative to traditional methods to reveal MS adhesins.

Adhesins, Escherichia coli↗

A method for the determination of the adherence of granulocytes to microtitre plates.

We report a new partially automated method for the measurement of the adherence of PMN in vitro. Adherence to a plastic surface was detected by measuring leukocyte alkaline phosphatase activity of the adherent cells, with a Titertek Multiscan system. Using three different cellular concentrations (1 X 10(6), 5 X 10(5), 2.5 X 10(5) PMN/ml) the response curve was linear to 45 min and adhesion was maximal by 30 min. The specificity of the reaction was acceptable as was the assay reproducibility (intra-assay coefficient of variation less than 8%; inter-assay coefficient of variation less than 11%).

Alkaline Phosphatase↗