PubMed Health⌕ Search

Biomedical subjects

D Vollmer

Publications and source records attributed to D Vollmer.

At least 19 recordsLinked to original sources

Regulation of mesenchymal stem cell and chondrocyte differentiation by MIA.

Melanoma inhibitory activity (MIA), also referred to as cartilage-derived retinoic acid-sensitive protein (CD-RAP), an 11-kDa secreted protein, is mainly expressed in cartilaginous tissue during embryogenesis and adulthood. Currently, the function of MIA in cartilage tissue is not understood. Here, we describe that MIA acts as a chemotactic factor on the mesenchymal stem cell line C3H10T1/2, stimulating cell migration significantly at concentrations from 0.24 to 240 ng/ml, while inhibiting cell migration at higher doses of 2.4 microg/ml. When analyzing the role of MIA during differentiation processes, we show that MIA by itself is not capable to induce the differentiation of murine or human mesenchymal stem cells. However, MIA influences the action of bone morphogenetic protein (BMP)-2 and transforming growth factor (TGF)-beta 3 during mesenchymal stem cell differentiation, supporting the chondrogenic phenotype while inhibiting osteogenic differentiation. Quantitative RT-PCR analysis revealed the up-regulation of the cartilage markers MIA, collagen type II and aggrecan in human mesenchymal stem cell (HMSC) cultures differentiated in the presence of MIA and TGF-beta 3 or BMP-2 when compared to HMSC cultures differentiated in the presence of TGF-beta 3 or BMP-2 alone. Further, MIA down-regulates gene expression of osteopontin and osteocalcin in BMP-2 treated HMSC cultures inhibiting the osteogenic potential of BMP-2. In the case of human primary chondrocytes MIA stimulates extracellular matrix deposition, increasing the glycosaminoglycan content. Therefore, we postulate that MIA is an important regulator during chondrogenic differentiation and maintenance of cartilage.

Adult↗

Phase separation in binary fluid mixtures with continuously ramped temperature.

We consider the demixing of a binary fluid mixture, under gravity, which is steadily driven into a two-phase region by slowly ramping the temperature. We assume, as a first approximation, that the system remains spatially isothermal, and we examine the interplay of two competing nonlinearities. One of these arises because the supersaturation is greatest far from the meniscus, creating inversions of the density which can lead to fluid motion; although isothermal, this is somewhat like the Bénard problem (a single-phase fluid heated from below). The other is the intrinsic diffusive instability which results either in nucleation or in spinodal decomposition at large supersaturations. Experimental results on a simple binary mixture show interesting oscillations in heat capacity and optical properties, for a wide range of ramp parameters. We argue that these oscillations arise under conditions where both nonlinearities are important.

Journal Article↗

Mechanical tension in distraction osteogenesis regulates chondrocytic differentiation.

Differentiation of chondrocytes to cells of osteoblastic phenotype occurs during an interim period of bone development, fracture repair and distraction osteogenesis. To study the relationship between tension-stress and chondrogenesis, uniaxial strains (0 microstrains, 2000 microstrains, 20000 microstrains, 200000 microstrains, 300000 microstrains) were applied in a rabbit model of mandibular distraction osteogenesis. The results demonstrated that cell differentiation, apoptosis and tissue development in the newly formed gap tissue showed a correlation to the applied strain magnitudes. Only strains of 20000 microstrains resulted in a statistically significant (P<0.05) formation of cartilage struts with embedded chondrocyte-like cells. However, chondrocyte-like cells were rarely detected in samples distracted at lower or higher strain magnitudes. Osteoblasts appeared to replace cartilaginous matrix by mineralized bone matrix. The phenotypic change from chondrocytes to osteoblasts was accompanied by a decreased proteoglycan synthesis. a change in the expression from type II collagen towards type I and involved asymmetric cell divisions and apoptotic cell death. Therefore, we suggest that mechanical strain is an external stimulus responsible for phenotypic cell alterations.

Analysis of Variance↗

Bone loading pattern around implants in average and atrophic edentulous maxillae: a finite-element analysis.

Introduction: Oral implants placed in the maxilla, especially the posterior region, have a lower success rate than those placed in the mandible. Poor bone quantity and quality have been suggested as a reason for this differential success rate. Objective: The purpose of this study was, therefore, to evaluate stress and strain distributions around loaded implants in the normal and atrophic maxilla by finite-element (FE) analyses. Material: FE models of a solitary implant were generated to determine stresses and strains in the bone adjacent to the implant surface under loading conditions. Study design: Different bony situations and implant lengths were used in a FE model. Static loads were applied axially and the resulting stresses and strains calculated. Results: Bone quality and quantity play a major role in decreasing bone strains adjacent to the implant surface under loading. It was found that stresses were more homogeneously distributed when more spongy bone was present. Decreased bone height was found to have less pronounced effects on strain and stress alterations than poor bone quality. Atrophic bony dimensions in combination with poor bone quality were associated with surface strains exceeding physiological levels (>6000 microstrains). Conclusion: Our investigation indicates that supraphysiological bone strains adjacent to the implant surface should be expected under mechanical loading in the atrophic maxilla. Copyright 2001 European Association for Cranio-Maxillofacial Surgery.

Journal Article↗

Antimicrobial resistance and bacterial identification utilizing a microelectronic chip array.

Species-specific bacterial identification of clinical specimens is often limited to a few species due to the difficulty of performing multiplex reactions. In addition, discrimination of amplicons is time-consuming and laborious, consisting of gel electrophoresis, probe hybridization, or sequencing technology. In order to simplify the process of bacterial identification, we combined anchored in situ amplification on a microelectronic chip array with discrimination and detection on the same platform. Here, we describe the simultaneous amplification and discrimination of six gene sequences which are representative of different bacterial identification assays: Escherichia coli gyrA, Salmonella gyrA, Campylobacter gyrA, E. coli parC, Staphylococcus mecA, and Chlamydia cryptic plasmid. The assay can detect both plasmid and transposon genes and can also discriminate strains carrying antibiotic resistance single-nucleotide polymorphism mutations. Finally, the assay is similarly capable of discriminating between bacterial species through reporter-specific discrimination and allele-specific amplification. Anchored strand displacement amplification allows multiplex amplification and complex genotype discrimination on the same platform. This assay simplifies the bacterial identification process greatly, allowing molecular biology techniques to be performed with minimal processing of samples and practical experience.

Anti-Bacterial Agents↗

[Planning orthodontic surgery with the Hexapod system].

Treatment of maxillofacial dysgnathia using a combined surgical/orthodontic approach requires careful orthodontic and orthognathic diagnosis and treatment planning. In the present study, a system enabling on-line presentation of the necessary displacements of the jaw during surgery, while improving the accuracy of the planning, is described. Using the hexapod principle, it is possible to plan operations with six degrees of freedom and to measure the three-dimensional movements of jaws and jaw segments within the planning stage. Routinely prepared casts are employed for simulation of the operation. The displacements of the jaw are presented in a manner familiar to the orthodontic surgeon, namely in a surgical record. The accuracy achieved with the hexapod is superior to that achievable intra-operatively.

Computer Simulation↗

Prospective study on the reproducibility of cephalometric landmarks on conventional and digital lateral headfilms.

The introduction of digital X-ray techniques offered a variety of new possibilities for digital image enhancement and exposure reduction. In order to compare the reproducibility of cephalometric landmarks on conventional and digital lateral headfilms 100 digital and 100 conventional lateral headfilms of patients attending our clinic were randomly selected. The digital cephalograms were obtained using storage phosphor plates in standard X-ray cassettes. All X-rays had been taken at 77 kV. For the digital images the mAs settings for conventional images minus 4 mAs were used. Two orthodontists traced each X-ray twice (21 reference points) at an interval of at least 1 week. The tracings were superimposed and the distances between the tracings of identical reference points were registered. The average reproducibility of cephalometric landmarks was significantly higher on the digitally obtained images, despite a reduction of radiation exposure of 23.7% in the digital images.

Cephalometry↗

Application of bone remodeling theories in the simulation of orthodontic tooth movements.

A numerical model that calculates bone apposition and resorption around a tooth root on the basis of bone remodeling theories was developed to simulate orthodontic tooth movements. The model was used to calculate different kinds of orthodontic tooth movements, that were then compared with the expected movements based on clinical experience. For simulation of the movements the root of a canine was modeled in an idealized way in the form of an elliptical paraboloid and was processed with a finite element program. The finite element model was loaded with defined force systems. Two model assumptions were used to calculate the bone remodeling process. The mechanical loads firstly in the periodontal ligament and secondly in the alveolar bone were taken to simulate the following tooth movements: 1. mesial tipping around the center of resistance (force system at the bracket: isolated torque MY = 5 Nmm), 2. rotation around the long axis of the tooth (MZ = 5 Nmm), 3. uncontrolled tipping around the root tip (FX = 1 N, MZ = 5 Nmm), 4. canine retraction (FX = 1 N, MY = -9.5 Nmm, MZ = 5 Nmm), 5. and 6. extrusion/intrusion (FZ = +/- 0.5 N, MX = +/- 2.5 Nmm). Comparison with clinical experience was performed by calculating the orthodontic tooth movements based on the assumption of a fixed position of the center of resistance. It could be demonstrated that the numerical model of orthodontic bone remodeling can be used to calculate orthodontic tooth movements. However, the results are strongly dependent on the model assumptions. The model simulating the bone remodeling on the basis of the loading of the periodontal ligament delivers results that are in very good accordance with the biomechanical assumptions of the position of the center of resistance. However, marked side effects occurred with the second model, especially in the simulations of uncontrolled tipping, translation and intrusion/extrusion. Clinically, these side effects cannot be observed.

Bone Remodeling↗

[Experimental and finite-element models for the assessment of mandibular deformation under mechanical loading].

Biomechanical investigations of the mandible are difficult to perform due to a variety of conditions involved. For the appropriate reconstruction of biomechanical properties, a geometrically correct body model has to be established which fits to complex in vivo conditions. The aim of our study was to evaluate the use of finite-element models (FEM) for the assessment of mandibular deformation under mechanical loading. Explanted human mandibles (n = 5) were investigated by strain gauges to determine the individual strain distribution under mechanical loading. FEM analysis based on a computed tomograph (CT) was performed and the results were matched with the test data. Our study demonstrates only minor interindividual differences in the strain distribution for each load studied. The mechanical response in terms of deformation was found to depend mainly on gross geometrical properties and to a minor extent on the various other variables. At all positions the maximum principal strain was tensile, the minimum principal strain was compressive, and the absolute strain values were correlated with the magnitude of the applied force. CT-based FEM analysis revealed the utility of mathematical models to approximate simulated data our experimental results. Hence, FEM analysis is a non-invasive tool in the prediction of biomechanical behaviour of individual mandibles and therefore may help in trauma reconstruction and treatment planning.

Biomechanical Phenomena↗

[Effect of implant geometry on strain distribution in peri-implant bone].

Recent developments and results in the field of mechanical bone stimulation have made it possible to define limits between physiological and non-physiological transmission of strength to the bone. Now it is necessary to investigate the different geometries of dental implants regarding biomechanical reliability. The aim of this study was to examine the distribution of strain on the bone along different basic forms of implants during loading using finite element analysis (FEA). The following implant designs were included in the study: cylinder, threaded cylinder, cylinder with steps, threaded cylinder with steps, and double-disk implants. All implants had a length of 12 mm and a diameter of 4 mm, the axial loading was defined as 300 N. Threaded implants showed more homogeneous distribution of strain than stepped implants, however, the maximum values were below the physiological range. Shortening of the implants led to an increase of the values, however, there was a zone of hypophysiological strain apically. Disk implants showed extremely low values at the disk margins, possibly due to the lack of physiological bone stimulus by the disks. Overall, none of the implants showed optimal distribution of strain, even though homogeneous strain distribution is decisive for long-term implant stability.

Alveolar Process↗

Experimental and finite element study of a human mandible.

Knowledge of the complex biomechanical behaviour of the human mandible is of great importance in various clinical situations. Various approaches can be used to evaluate the physical behaviour of bony specimens. In the course of this study, we investigated mandibular deformation under mechanical loads in an experimental setting and compared them with results derived from finite element analysis (FEA). A special apparatus was developed to apply various forces under defined conditions on an explanted human mandible in vitro. Strains on the surface of the mandible were measured with strain gauges and subsequently a voxel based finite element mesh was generated. Strain patterns of the mandible were calculated in the FE analysis and matched with the experimental data. Comparing the numerical with the experimental data, we found a good correlation between in vitro measurements and mathematical modelling (correlation coefficient = 0.992). Then the FE model was used to evaluate mandibular biomechanics relative to aspects of load transfer, stress distribution and displacements. It is concluded that the applied procedure of generating the FE model is a valid and accurate, non-invasive method to predict different parameters of the complex biomechanical behaviour of human mandibles.

Biomechanical Phenomena↗

[Semi-automatic generation of finite element meshes fo dental preparations].

The mechanical properties and elastic behaviour of periodontal tissue are a decisive factor in understanding initial tooth mobility and bone remodelling processes in orthodontics. An experimental set-up was designed to precisely determine a tooth's elastic response to different loading conditions. Segments of pig's maxilla bearing separated molars were used, and their mechanical response to loading was recorded. Subsequently, finite element analysis (FEA) was performed on the basis of the experimental data. The combination of experimental and numerical methods was used to determine the material properties of the periodontal ligament (PDL). The geometries of the preparations were reconstructed and FE meshes generated semi-automatically with the aid of the special computer program, CAGOG (Computer Aided Generator for Orthodontic Geometries) to optimally match the experimental geometry. Nonlinear material parameters were determined for the PDL and verified by comparing experimental and numerical results obtained in other specimens with an error of about 10%. This good correlation indicates that the selected method of mesh generation is appropriate for creating realistic FE models that can be compared with experimental results.

Animals↗

Simulation of orthodontic tooth movements. A comparison of numerical models.

Orthodontic tooth movements are based on the ability of bone to react to mechanical stresses with the apposition and resorption of alveolar bone. Currently, the underlying biophysical, biochemical, and cellular processes are the subject of numerous studies. At present, however, an analytical description of orthodontic tooth movements including all components of the processes involved seems to be impossible. It was the aim of the present study to develop a mechanics-based phenomenological model capable of describing the alveolar bone remodeling. Thus, 2 different models were developed. The first is based on the assumption that deformations of the periodontal ligament (PDL) are the key stimulus to starting orthodontic tooth movement. The second supposes that deformations of the alveolar bone are the basis of orthodontic bone remodeling. Both models were integrated into a finite element package calculating stresses, strains and deformations of tooth and tooth supporting structures and from this simulating the movement of the tooth and its alveolus through the bone. Clinically induced canine retractions in 5 patients as well as force systems were exactly measured and the tooth movements were simulated using both models. The results show that the first model allows reliable simulation of orthodontic tooth movements, whereas the second is to be rejected.

Alveolar Process↗

Determination of the centre of resistance in an upper human canine and idealized tooth model.

The purpose of this investigation was to analyse the influence of geometric and material parameters of a human canine on initial tooth mobility, and the stress and strain profiles in the periodontal ligament. While the material parameters of tooth and bony structures are known within an uncertain limit of approximately a factor of 10, values reported for the elasticity parameters of the periodontal ligament differ significantly. In the course of this study, bilinear behaviour was assumed for the mechanical property of the periodontium. The finite element model of an elliptical paraboloid was created as an approximation to the geometry of a human canine to reduce calculation time and to determine influences of the geometry on numerical results. The results were compared with those obtained for a realistic human canine model. The root length of both models was 19.5 mm. By calculating pure rotational and pure tipping movements, the centre of resistance (CR) was determined for both models. They were located on the long axis of the tooth approximately 7.2 mm below the alveolar crest for the idealized model and 8.2 mm for the canine model. Thus, the centre of resistance of a human canine seems to be located around two-fifths of the root length from the alveolar margin. Using these results, uncontrolled tipping (1 N of mesializing force and 5 Nmm of derotating momentum), as well as pure translation (additionally about 10 Nmm of uprighting momentum) were calculated. Comparing the idealized and the realistic models, the uncontrolled tipping was described by the parabolic-shaped model within an accuracy limit of 10 per cent as compared with the canine model, whereas the results for bodily movement differed significantly showing that it is very difficult to achieve a pure translation with the realistic canine model.

Computer Simulation↗