Experimental three dimensional strain estimation from ultrasonic sectorial data.

Most of the studies devoted to elastography are focused on the estimation of the axial component of the strain. However when subjected to any load, whatever the direction, soft biological media deform in the three spatial dimensions. The aim of our work is to build a three dimensional strain mapping from data acquired with a 3D clinical sectorial probe. The estimation of radial strain is based on the estimation of local scaling factors. A method of cross-correlation of interpolated signals between adjacent radiofrequency lines was used to estimate the angular displacement and strain. For the sectorial strain estimation, the same displacement estimation technique has been implemented. The method has been tested on experimental data acquired on calibrated phantoms and compared to simulation.

Algorithms↗

Estimation methods for flow imaging with high frequency ultrasound.

This article proposes to estimate slow blood flow with high frequency ultrasound imaging. The proposed technique combines 2 methods. First, a statistical method, called Speckle Flow Imaging (SFI) based on the analysis of changes in the speckle pattern along time, gives an index directly related to the total velocity vector. Secondly, a block matching approach estimates the in-plane velocity components. Results on calibrated flow sequences of blood mimicking fluid have shown good agreement with the statistical model. The quantification of flow is achieved with pulsed flow and is also angle independent when the flow is perpendicular to the ultrasound beam. Speckle Tracking has been evaluated on the same data and has shown good estimation of the in-plane velocity vector when the component of velocity perpendicular to the imaging plane is inferior to 1mm/s. The results of these two methods permit the evaluation of the total 3D velocity field and the orthogonal velocity component relative to the imaging plane. This allows the quantification of blood flow (volumetric per time unit across the sequence).

Algorithms↗

Ultrasound detection of spontaneous hepato-cellular carcinomas in X/myc bitransgenic mice.

AIMS: To evaluate trans-abdominal ultrasound for the detection of Hepatocellular carcinoma (HCC) in a bitrasgenic murine (X/myc) model using a commercially available high-frequency ultrasound unit. METHODS: Sixty-one female animals were included in this study. These animals were submitted to a single ultrasound examination of the liver under general anesthesia (isoflurane), and then euthanized. Results of ultrasound were compared with necropsy and histopathology. RESULTS: The lesions demonstrated a fairly consistent aspect (oval- or round-shaped, well-defined hypoechoic homogeneous lesions), and lesions as small as 2 mm were identified. For detection of hepatic nodules per mouse the sensitivity was 75%, the specificity was 100% and the accuracy was 88.5%. For detection of hepatic focal lesions per lesions the overall sensitivity was 60%, the specificity was 97%, and the accuracy was 75.9%. Contrast-enhanced harmonic ultrasound imaging did not improve the identification of the lesions in our experimental conditions. CONCLUSION: High-frequency ultrasound appears to be an efficient tool allowing new possibilities to use this animal model and evaluate new therapies in longitudinal studies, which are much more powerful.

Animals↗

Axial strain imaging of intravascular data: results on polyvinyl alcohol cryogel phantoms and carotid artery.

Mapping the local elastic properties of an atherosclerotic artery is of major interest for predicting the disease evolution or an intervention outcome. These properties can be investigated by elastography, which estimates the strain distribution within a medium in response to a stress. But because diseased arteries are highly heterogeneous, a small global deformation may result in high local strains in the softest regions. For those reasons, we use in this paper the strain estimation method we recently developed to compute elastograms of original vessel-mimicking cryogel phantoms and a fresh excised human carotid artery. This adaptive method has been effectively proved to be accurate in a wider range of strains (0-7%) than commonly used gradient-based methods, and very adapted for investigating highly heterogeneous tissues. Resulting elastograms cover a wider range of strains (0-3.5%) than all previously reported intravascular elastograms, improving the discrimination between healthy and diseased regions.

Carotid Artery Diseases↗

Synthetic aperture-based beam compression for intravascular ultrasound imaging.

In this paper, intravascular ultrasound (IVUS) images acquired with a 64-element array transducer using a multistatic acquisition scheme are presented. The images are reconstructed from a collection of pulse-echo measurements using a synthetic aperture array imaging technique. The main limitations of IVUS imaging are a poor lateral resolution and elevated grating lobes caused by the imaging geometry. We propose a Synthetic Aperture Focusing Technique (SAFT), which uses a limited number of A-scan signals. The focusing process, which is performed in the Fourier domain, requires far less computation time than conventional delay-and-sum methods. Two different reconstruction kernel functions have been derived and are compared for the processing of experimental data.

Computer Simulation↗

Axial strain imaging using a local estimation of the scaling factor from RF ultrasound signals.

The main signal-processing techniques used in elastography compute strains as the displacement derivative. They perform well for very low deformations, but suffer rapidly from decorrelation noise. Aiming to increase the range of accurate strain measurements, we developed an adaptive method based on the estimation of strains as local scaling factors. Its adaptability makes this method appropriate for computing scaling factors resulting from larger strains or a wide spread of strain variations. First, segments corresponding to the same part of tissue are adaptively selected in the rest and stressed state echo signals. Then, local scaling factors are estimated by iteratively varying their values until reaching the zero of the phase of the complex cross-correlation function. Results from simulation and from experimental data are presented. They show how this adaptive method can track various local deformations and its accuracy for strain up to 7%.

Algorithms↗

Modeling geometric artefacts in intravascular ultrasound imaging.

A model has been developed for estimating the geometric distortions in intravascular ultrasound (IVUS) imaging caused by the position of the ultrasound catheter within the artery. Geometric distortion causes degradation on cross-sectional images of the vessel wall where, for characteristic positioning of the transducer within the vessel, a circular artery is seen on IVUS images as a noncircular vessel represented by more or less complex shapes. Artefacts, therefore, have a clinical impact on the accuracy of qualitative and quantitative intravascular analyses. The main distortions are due to the inclination and the off-centered position of the transducer within the vessel. These effects are increased by two factors: first, the point of origin of the ultrasound beam does not coincide with the rotation axis of the catheter; second, in the case of a mechanical rotating transducer, the ultrasound beam is not perpendicular to the long axis of the catheter, but has an inclination such that the transducer looks forward from the emitting point. All these parameters are taken into account in the three-dimensional (3-D) geometric model developed in this paper. The model was formulated to predict the geometric deformation for artery contour of various shapes and can model artefacts during stent implantation (Finet et al. 1998). Simulations were made for various geometric configurations and compared to in vitro and in vivo IVUS images. The model results are consistent with the experimental results. Finally, the model was used for estimating the values of the geometric parameters that cause distortions on ultrasonic images.

Arteries↗