Peroneal nerve palsy following intermittent sequential pneumatic compression.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to D W Burke.
Explore the source record for details and available documents.
We observed a case of early-onset osteolysis in a cemented total knee arthroplasty. Preoperative radiographs suggested numerous radiopaque particles covering the polyethylene insert. Findings at the time of revision confirmed the presence of small radiopaque polymethylmethacrylate particles on the bearing surface of the tibial insert, presumably leading to early failure of the knee arthroplasty.
Dislocation of the hip except as a congenital or developmental lesion is not common, and the onset of symptoms because of posterior instability of the hip in an adult has not been reported previously. An adult patient who had benign congenital hypotonia as an infant and who presented with generalized ligamentous laxity and hip pain associated with recurring posterior subluxation of the hip is the subject of this report.
The strains in the cement mantle surrounding the cemented femoral component of a total hip replacement were measured in vitro, using strain gauges embedded within the cement mantle adjacent to the femoral component in femurs from cadavers under physiologic loads simulating both single-limb stance and stair-climbing. Cement strains in the most proximal portion of the cement mantle were measured with and without full contact of the collar of the femoral stem on the cortex of the medial portion of the femoral neck during both loading conditions. To our knowledge, these are the first studies to contrast by direct measurement the strain profile in the cement mantle of a cemented femoral component under simulated stair-climbing with that occurring under simulated single-limb stance. They extend the findings from finite element analyses and from clinical specimens retrieved at autopsy in identifying those regions of the cement mantle most likely to fail. At two specific foci, the magnitude of the strain in the cement mantle approaches values that could lead to early fatigue failure of the cement. The two regions in which the strains were highest (greater than 1,000 microstrain) were the most proximal portions of the cement mantle and near the tip of the femoral component. Although these two regions are recognized areas of high strain and also common sites of cement debonding and cement mantle failure, the strain-gauge studies showed that the magnitude of cement strains in the proximal portion of the cement mantle were highest during stair-climbing; in contrast, high strains at the tip region occurred in both gait and stair-climbing. Contact between the collar and the medial portion of the femoral neck reduced the strain in the proximal portion of the cement mantle not only in single-limb stance but in stair-climbing as well. The level of strain recorded in these studies for a simulated person weighing 115 pounds (52 kg) could lead to cement fracture during extended in vivo service life of a cemented femoral component, from either single-limb stance or stair-climbing. This risk would be increased if a void or defect existed in the cement mantle at these sites. Moreover, the increase in strain in the cement mantle was linear with increases in body weight between 100 and 200 pounds (45 and 91 kg) of spinal load, indicating that strains in a heavy patient could readily exceed the fatigue limit of the cement, particularly if a stress riser such as a pore in the cement or a sharp corner of the prosthesis were present. These data reemphasize the need to continue efforts to develop methods to strengthen bone cement and to reduce those factors that increase the strain in the cement mantle of cemented femoral components of total hip arthroplasty, particularly proximally and near the tip.
RATIONALE AND OBJECTIVES: To determine the volume of articular cartilage in cadavers, patients, and healthy volunteers by using a volumetric, fat-suppressed spoiled gradient-recalled signal acquisition in the steady state (SPGR) magnetic resonance (MR) sequence. METHODS: Sagittal MR images were obtained with a fat-suppressed SPGR sequence (repetition time, 52 msec; echo time, 10 msec; 60 degrees flip angle; 3.0-3.5-mm partitions, 256 x 192 matrix, two signals acquired). The cartilaginous surfaces of the tibia, femur, and patella were planimetrically defined with a three-dimensional workstation. A three-dimensional model volume was created by threshold segmenting the cartilage from the adjacent tissues. The volume as calculated by using MR imaging was compared with the actual volume of the cartilage specimens. RESULTS: Observed measurements correlated with actual weight and volume displacement measurements with an accuracy of 82%-99% and linear correlation coefficients of 0.99 (P = 2.5e-15) and 0.99 (P = 4.4e-15). Precision of segmentation in healthy volunteers yielded a coefficient of variation of 0.4% for interobserver variability and 0.3% for intraobserver variability. CONCLUSION: This pilot study suggests that accurate volumetric calculations of knee articular cartilage are possible with currently available MR imaging pulse sequences and a commercially available work station.
A technique is described for cementing of the patellar component in total knee arthroplasty that involves pressurization of cement into the patellar-component lug holes, which are drilled in the bone prior to cementing the component. A radiographic comparison of cement penetration with this method versus that obtained by using conventional techniques is illustrated.
Explore the source record for details and available documents.
We report complications from the use of modular components in 20 hip replacements in 18 patients. Fifteen complications (in 13 patients) were related to failure of a modular interface after operation. Femoral head detachment from its trunnion was seen in 6 hips from trauma (3), reduction of a dislocation (2), and normal activity (1). In one case the base of the trunnion fractured below an extra-long modular head. In seven other hips the modular polyethylene liner dislodged from its shell, causing severe damage to the shell in four cases with extensive metallosis. In one other hip an asymmetrical polyethylene liner rotated, resulting in impingement of the femoral component and recurrent dislocation. Operative errors were seen in five cases: implantation of a trial acetabular component in one; and mismatching between the size of the femoral head and the acetabular component in the others. Surgeons who use hip replacements with modular components should be aware of the potential for operative error and of the importance of early treatment for postoperative mechanical failure.
The magnitude of the offset of the femoral prosthesis strongly influences the mechanics of the hip following a total hip arthroplasty. An increased offset increases the moment arm of the abductor muscles. This reduces the abductor force required for normal gait and, consequently, reduces the resultant force across the hip joint. These factors are advantageous. However, increased offset also increases the bending moment on the implant, which could adversely increase the strain in the medial cement mantle. To evaluate the relative advantages and disadvantages of these conflicting results of increasing the offset of the femoral component the authors measured in vitro in cadaver femora the effect of differing offsets of the femoral component on strain in the cement mantle. After testing the intact femora, the authors cemented femoral prostheses in place and quantified the abductor force, resultant force, and strain in the cement mantle under loading conditions simulating single limb stance at different femoral offset levels. The reduction in both abductor and resultant force was substantial with increased femoral component offset, but the strain in the cement of the proximal medial portion of the cement mantle was not significantly increased.
In order to study initial mechanisms of failure in cemented femoral total hip components, an anatomically accurate three-dimensional linear finite element model was constructed and verified against experimental strain measurements in the cement mantle. Good agreement was found between predicted and measured strains. The likelihood of failure initiation due to cement-prosthesis debonding and crack initiation at voids was studied for loading conditions simulating both one-legged stance and stair climbing. The "out of plane" forces involved in stair climbing appear to be the greatest threat to the fixation of total hip replacements. In stair climbing, cement-prosthesis debonding and pore crack initiation were probable in the proximal anteromedial region of the cement mantle, and near the distal tip of the implant. The proximal stresses in stair climbing were higher than the distal stresses in either stair climbing or one-legged stance.
The prosthetic range of motion (PROM) of two modular total hip arthroplasty (THA) systems and one older nonmodular comparison system was evaluated. The head-neck geometry of the modular systems resulted in a smaller PROM than the nonmodular system. Longer head-neck components commonly had flanges, which caused the greatest reduction in PROM. This effect became more pronounced as head size decreased. Modular head-neck components offer recognized benefits but can be associated with notably smaller ROM and increased risk of prosthetic impingement. The surgeon should be aware that in modern systems PROM decreases when neck width is increased. Moreover, in cases of prosthetic instability the potential role of the flange of a modular head should be evaluated. Methods are suggested for maximizing PROM clinically through preoperative planning, optimal femoral neck resection, and implant utilization.
We evaluated the initial stability of cemented and uncemented femoral components within the femoral canals of cadaver femurs during simulated single limb stance and stair climbing. Both types were very stable in simulated single limb stance (maximum micromotion of 42 microns for cemented and 30 microns for uncemented components). However, in simulated stair climbing, the cemented components were much more stable than the uncemented components (76 microns as against 280 microns). There was also greater variation in the stability of uncemented components in simulated stair climbing, with two of the seven components moving 200 microns or more. Future implant designs should aim to improve the initial stability of cementless femoral components under torsional loads; this should improve the chances of bony ingrowth.
The effect of "elevated-rim" (ER) acetabular components on prosthetic range of motion (ROM) and stability was studied in a laboratory simulator using three contemporary total hip arthroplasty (THA) systems. Acetabular components were tested in positions simulating both normal alignment and excess abduction. The geometry of the implants differed between systems--two types were identified, and their effect on ROM in comparison with their corresponding plain liners were quantified. The ability of the liners to improve instability appeared to be dependent on the cause of instability, the orientation of the metal shell and ER liner, and the ER liner geometry. The routine use of ER liners in otherwise satisfactorily positioned acetabular components appeared to offer no demonstrable benefit and raised concern over theoretical disadvantages. The primary indication for these implants appeared to be in cases of instability due to acetabular malposition in which the metal shell is already well fixed by cement or bone ingrowth or cannot be readily changed.
High out-of-plane forces acting on the hip joint can produce important rotational micromotion of the femoral component. This micromotion at the prosthesis interface may be detrimental to the stability of the implant. In cementless femoral implants this could prevent bone ingrowth, and in the cemented component this could cause generation of particulate debris, lysis, and loosening. The introduction of the torque wrench micrometer for assessment of intraoperative femoral component stability can quantify the initial stability of primary cementless femoral components and critically evaluate the stability (at either the initial or revision arthroplasty) of both cemented and cementless femoral components. It allows the surgeon to produce a known torque in the direction and magnitude of the out-of-plane forces that load the hip in vivo.
The total porosity and mean pore sizes of various bone cement preparations were measured using image analysis. The porosity in different commercial bone cements varied from 5% to 16% when these cements were prepared in the usual fashion. Centrifugation for 30 seconds resulted in a substantial reduction in the overall porosity of Simplex P, AKZ, Zimmer Regular, and CMW bone cements by reducing both the mean pore size and the number of pores per unit area. In contrast, the porosity of LVC, Palacos R, and Palacos R with gentamicin bone cements was not significantly decreased by centrifugation. Chilling the monomer before mixing resulted in higher porosity of both the centrifuged and uncentrifuged Simplex P, Zimmer Regular, and CMW bone cements. Simplex P mixed with chilled monomer and centrifuged for 120 seconds has one of the lowest porosities of the various cements, while retaining good handling characteristics and excellent fatigue strength.
The fatigue properties of Simplex P and Palacos R bone cements were compared to their antibiotic impregnated counterparts AKZ* and Palacos R with gentamycin. The effect of porosity reduction by centrifugation of all four cement types was also assessed. Fifteen specimens of each cement type were prepared according to manufacturer's instructions and 15 additional specimens of each cement type were prepared by mixing the powder with chilled monomer (0 degrees C) and then centrifuging the cement immediately after mixing. Fifteen fully reversed tension-compression fatigue tests were performed at 15 MPa in stress control for each cement preparation in vitro while simulating the in vivo state (37 degrees C and 100% humidity). The number of cycles to failure were recorded. There was no significant difference in the fatigue life of Palacos R and Simplex P when both cements were prepared in the standard fashion. The addition of 1/2 g of gentamycin to Palacos R did not significantly alter its fatigue properties. The addition of 0.5 g of erythromycin and 0.24 g of colistin did not decrease the fatigue life of Simplex P. Centrifugation significantly improved the fatigue properties of Simplex P and AKZ. The fatigue lives of Palacos R and Palacos R with gentamycin were not improved by centrifugation. The fatigue life of centrifuged Simplex P was significantly greater than the fatigue life of Palacos R and of Palacos R with gentamycin, whether the Palacos R based cements were centrifuged or not.
Simplex P bone cement was spun for 30, 60, and 120 seconds in three different centrifugation systems (I.E.C. HN-S II, I.E.C. clinical, and Johnson & Johnson) to determine whether differences among the three systems also produce differences in the improvement of the fatigue strength of the cement. The fatigue properties of the cement after centrifugation were also assessed when it was mixed with monomer that had been chilled to 0 degrees C. There were important and statistically significant differences in the fatigue life of Simplex P spun for the same duration in the different centrifuges. Simplex P prepared as recommended by the manufacturer had an average fatigue life of 15,143 cycles in the test system used. Optimum centrifugation among the techniques studied increased the fatigue life nearly fivefold, to the range of 71,000 cycles. Taking into account both the fatigue strength and the viscosity of the cement, the optimum centrifugation system for improving the fatigue life of Simplex P bone cement is the Miller cartridge containing two packs of cement spun in the IEC-HN-S II centrifuge. The authors recommend 30 seconds of centrifugation if the monomer is not chilled prior to mixing and 60 seconds if the monomer is chilled.
We have tested the porosity and fatigue life of five commonly used bone cements: Simplex P, LVC, Zimmer regular, CMW and Palacos R. Tests were conducted with and without centrifugation and with the monomer at room temperature and, except for LVC, at 0 degrees C. We found that the fatigue life of different specimens varied by a factor of nearly 100. It did not depend on porosity alone, but was more influenced by the basic composition of the cement. Simplex P when mixed with monomer at 0 degrees C and centrifuged for 60 seconds had the highest fatigue life and was still sufficiently liquid to use easily.