PubMed Health⌕ Search

Biomedical subjects

D W Grijpma

Publications and source records attributed to D W Grijpma.

At least 19 recordsLinked to original sources

In vivo and in vitro degradation of poly(ether ester) block copolymers based on poly(ethylene glycol) and poly(butylene terephthalate).

Two in vivo degradation studies were performed on segmented poly(ether ester)s based on polyethylene glycol (PEG) and poly(butylene terephthalate) (PBT) (PEOT/PBT). In a first series of experiments, the in vivo degradation of melt-pressed discs of different copolymer compositions were followed up for 24 weeks after subcutaneous implantation in rats. The second series of experiments aimed to simulate long-term in vivo degradation. For this, PEOT/PBT samples were pre-degraded in phosphate buffer saline (PBS) at 100 degrees C and subsequently implanted. In both series, explanted materials were characterized by intrinsic viscosity measurements, mass loss, proton nuclear magnetic resonance spectroscopy (1H-NMR) and differential scanning calorimetry (DSC). In both studies the copolymer with the higher PEO content degraded the fastest, although all materials degraded relatively slowly. To determine the nature of the degradation products formed during hydrolysis of the copolymers, 1000 PEOT71PBT29 (a copolymer based on PEG with a molecular weight of 1000 g/mol and 71 wt% of PEO-containing soft segments) was degraded in vitro at 100 degrees C in phosphate buffer saline (PBS) during 14 days. The degradation products present in PBS were analyzed by 1H-NMR and high performance liquid chromatography/mass spectroscopy (HPLC/MS). These degradation products consisted of a fraction with high contents of PEO that was soluble in PBS and a PEOT/PBT fraction that was insoluble at room temperature. From the different in vitro and in vivo degradation experiments performed, it can be concluded that PEOT/PBT degradation is a slow process and generates insoluble polymeric residues with high PBT contents.

Animals↗

Non-conventional injection molding of poly(lactide) and poly(epsilon-caprolactone) intended for orthopedic applications.

Biodegradable polymers such as poly(lactide) (PLA) and poly(epsilon-caprolactone) (PCL) are increasingly used in biomedical applications as temporary implants. However, melt processing of these materials in particular of PLA is difficult due to the temperature sensitivity. Within this study, PLA and PCL were injection molded conventionally and by using the process shear controled orientation in injection molding (SCORIM) in order to investigate the effect of processing parameters on the physical properties of the moldings. Therefore, flexural testing, differential scanning calorimetry (DSC), wide-angle X-ray diffraction (WAXD), molecular weight (MW) and orientation measurements were performed. PLA showed high sensitivity to melt temperature. In the case of amorphous poly(DL-lactide), the molecular weight and subsequently the ductility is substantially reduced by processing at higher melt temperatures. In the case of crystallizable poly(L-lactide), higher melt temperatures and shear induced by the SCORIM process resulted in enhanced crystallinity, which compromised the mechanical properties. Generally, SCORIM processing improved the mechanical properties, in particular the ductility, by orientating the molecular structure. PCL was shown to be less sensitive to shear and temperature than PLA. Stress at yield and stiffness are more improved by SCORIM processing. However, the processing temperature in combination with the grade used proved to be influential for the mechanical properties of resulting moldings.

Absorbable Implants↗

In vivo behavior of poly(1,3-trimethylene carbonate) and copolymers of 1,3-trimethylene carbonate with D,L-lactide or epsilon-caprolactone: Degradation and tissue response.

The degradation and the tissue response evoked by poly(1,3-trimethylene carbonate) [poly(TMC)] and copolymers of TMC with either 52 mol % D,L-lactide (DLLA) or 89 mol % epsilon-caprolactone (CL) were evaluated in vivo by subcutaneous implantation of polymer films in rats for periods up to one year. Poly(TMC) specimens were extensively degraded after 3 weeks and, as confirmed by histology, totally resorbed in less than a year. A fast linear decrease in thickness and mass without a change in molecular weight was observed. Initially an acute sterile inflammatory tissue reaction, caused by the implantation procedure, was observed, followed by a mild macrophage-mediated foreign body reaction that lasted during the resorption period of the polymer. It is concluded that in vivo, poly(TMC) is degraded via surface erosion involving cellular-mediated processes. The degradation of the copolymers was slower than that of poly(TMC), taking place via autocatalyzed bulk hydrolysis, preferentially of ester bonds. The TMC-DLLA copolymer degraded 20 times faster than the TMC-CL one. In both cases, the tissue reaction upon implantation resembled a sterile inflammatory reaction followed by a foreign body reaction that led to the polymer encapsulation. Significant mass loss was only observed for the TMC-DLLA copolymer, which underwent 96% mass loss in 1 year. When extensive mass loss started, a mild-to-moderate secondary foreign body reaction, related to clearance of the polymer fragments, was triggered. The results presented in this study demonstrate that poly(TMC) and both TMC copolymers are biodegradable and biocompatible materials, making these polymers attractive for the preparation of short- and long-term degradable devices for soft tissue engineering.

Animals↗

Gas plasma etching of PEO/PBT segmented block copolymer films.

A series of poly(ethylene oxide)/poly(butylene terephthalate) (PEO/PBT) segmented block copolymer films was treated with a radio-frequency carbon dioxide (CO(2)) or with argon (Ar) plasma. The effects of (preferential) etching on surface structure, topography, chemistry, and wettability were studied by scanning electron microscopy, atomic force microscopy, X-ray photoelectron spectroscopy, and contact angle measurements. In all cases, a granular-type nanostructure was formed after prolonged CO(2) plasma etching. Ar plasma etching generally did not lead to significant changes in surface structure. Regarding surface chemistry, CO(2) plasma treatment caused surface oxidation and oxidative degradation of the films while Ar plasma etching resulted mainly in the preferential removal of PEO blocks. The wettability of all films significantly increased after plasma treatment because of the creation of polar functional groups at the surface. Preliminary goat bone-marrow cell compatibility experiments have shown that all plasma-treated PEO/PBT films induced a greatly enhanced cell adhesion and/or growth compared to untreated biomaterials. This improvement was attributed to changes in surface chemistry during plasma etching rather than to changes in surface structure. These results show that plasma-treated PEO/PBT copolymers have a high potential as scaffolds for bone tissue regeneration.

Animals↗

Poly(ether ester amide)s for tissue engineering.

Poly(ether ester amide) (PEEA) copolymers based on poly(ethylene glycol) (PEG), 1,4-butanediol and dimethyl-7,12-diaza-6,13-dione-1,18-octadecanedioate were evaluated as scaffold materials for tissue engineering. A PEEA copolymer based on PEG with a molecular weight of 300 g/mol and 25wt% of soft segments (300 PEEA 25/75) and the parent PEA polymer (0/100) sustain the adhesion and growth of endothelial cells. The in vivo degradation of melt-pressed PEEA and PEA discs subcutaneously implanted in the back of male Wistar rats was followed up to 14 weeks. Depending on the copolymer composition, a decrease in intrinsic viscosity of about 20-30% and mass loss up to 12% were measured. During the degradation process, erosion of the surface was observed by scanning electron microscopy and light microscopy. The thermal properties of the polymers during degradation were measured by differential scanning calorimetry. During the first 2 weeks, a broadening of the melting endotherm was observed, as well as an increase in the heat of fusion. Porous matrices of PEEAs and PEA could be prepared by molding mixtures of polymer and salt particles followed by leaching of the salt.

Amides↗

Development and properties of polycaprolactone/hydroxyapatite composite biomaterials.

Polycaprolactone/hydroxyapatite (PCL/HA) composites were prepared by two different procedures. The first one consists of a conventional blending of the polymer and the reinforcement material in an extruder. The second method consists of grafting of PCL on the surface of HA particles. This was achieved by a ring opening polymerization of caprolactone in the presence of HA, where its OH groups act as initiators. By this method, it was possible to obtain, in one step, a composite of PCL and surface modified HA. In both methods different percentages of filler were used to obtain several composites. These composites were characterized with respect to their mechanical properties, in the dry and wet state, by means of tensile tests on compression molded samples. The polymer/filler interface was analyzed by scanning electron microscopy. Water uptake and weight loss degradation experiments were also performed. An increase in the modulus for higher amounts of filler was, as expected, observed in the composites obtained by both processes. Furthermore, the mechanical properties of the materials in the wet state are considerably lower than those in the dry state. However, this difference is more significant for the composites obtained by conventional blending than for composites obtained by the grafting procedure, indicating that the later procedure can be an adequate route to reduce water susceptibility of PCL/HA composites.

Journal Article↗

Preparation of degradable porous structures based on 1,3-trimethylene carbonate and D,L-lactide (co)polymers for heart tissue engineering.

Biodegradable porous scaffolds for heart tissue engineering were prepared from amorphous elastomeric (co)polymers of 1,3-trimethylene carbonate (TMC) and D,L-lactide (DLLA). Leaching of salt from compression-molded polymer-salt composites allowed the preparation of highly porous structures in a reproducible fashion. By adjusting the salt particle size and the polymer-to-particle weight ratio in the polymer-salt composite preparation the pore size and porosity of the scaffolds could be precisely controlled. The thermal properties of the polymers used for scaffold preparation had a strong effect on the morphology, mechanical properties and dimensional stability of the scaffolds under physiological conditions. Interconnected highly porous structures (porosity, 94%; average pore size, 100 microm) based on a TMC-DLLA copolymer (19:81, mol%) had suitable mechanical properties and displayed adequate cell-material interactions to serve as scaffolds for cardiac cells. This copolymer is noncytotoxic and allows the adhesion and proliferation of cardiomyocytes. During incubation in phosphate-buffered saline at 37 degrees C, these scaffolds were dimensionally stable and the number average molecular weight (Mn) of the polymer decreased gradually from 2.0 x 10(5) to 0.3 x 10(5) in a period up to 4 months. The first signs of mass loss (5%) were detected after 4 months of incubation. The degradation behavior of the porous structures was similar to that of nonporous films with similar composition and can be described by autocatalyzed bulk hydrolysis.

Biocompatible Materials↗

Evaluation of two biodegradable polymeric systems as substrates for bone tissue engineering.

The aim of this study was to evaluate two biodegradable polymeric systems as scaffolds for bone tissue engineering. Rat bone marrow cells were seeded and cultured for 1 week on two biodegradable porous polymeric systems, one composed of poly(ethylene glycol)-terephthalate/poly(butylene terephthalate) (PEGT/PBT) and the other composed of cornstarch blended with poly(epsilon-caprolactone) (SPCL). Porous hydroxyapatite granules were used as controls. The ability of cells to proliferate and form extracellular matrix on these scaffolds was assessed by a DNA quantification assay and by scanning electron microscopy examination; their osteogenic differentiation was screened by the expression of alkaline phosphatase. In addition, the in vivo osteogenic potential of the engineered constructs was evaluated through ectopic implantation in a nude mouse model. Results revealed that cells were able to proliferate, differentiate, and form extracellular matrix on all materials tested. Moreover, all constructs induced abundant formation of bone and bone marrow after 4 weeks of implantation. The extent of osteogenesis (approximately 30% of void volume) was similar in all types of implants. However, the amount of bone marrow and the degree of bone contact were higher on HA scaffolds, indicating that the polymers still need to be modulated for higher osteoconductive capacity. Nevertheless, the findings suggest that both PEGT/PBT and SPCL systems are excellent candidates to be used as scaffolds for a cell therapy approach in the treatment of bone defects.

Alkaline Phosphatase↗

In vitro degradation of Polyactive 1000PEOT70PBT30 devices.

Polyactive 1000PEOT70PBT30 (a segmented block copolymer of poly(ethylene oxide terephtalate)/poly(butylene terephtalate) with 70/30 PEOT/PBT ratio) was processed into three different types of samples: injection molded to rods, hot-pressed to films and to composite membranes made by hot-pressing a tubular mesh of poly-L,D-lactide 96/4 between two films of Polyactive. The molecular weight of Polyactive was not influenced by processing, but gamma-sterilization seemed to increase the weight average molecular weight (Mw). Mechanical properties of the rods and films decreased rapidly in hydrolytic conditions due to the hydrogel nature of the polymer, swelling and degradation. Mesh reinforcement increased the mechanical properties, but the components separated during soaking. In vitro the molecular weight of the rods and films started to decrease immediately, but the PEOT (or PEO) proportion remained relatively constant for 26 weeks. Macroscopically, all the wet devices remained intact, but fragmented on drying. Microscopically, topographical formations of polymer were found on the surfaces and small sodium-rich spots were precipitated onto and inside the polymer. Thermal measurements showed that polymer consisted of amorphous PEOT segments and both amorphous and crystalline PBT segments.

Biodegradation, Environmental↗

Control of vitamin B12 release from poly(ethylene glycol)/poly(butylene terephthalate) multiblock copolymers.

The release of vitamin B12 (1355 Da) from matrices based on multiblock copolymers was studied. The copolymers were composed of hydrophilic poly(ethylene glycol)-terephthalate (PEGT) blocks and hydrophobic poly(butylene terephthalate) (PBT) blocks. Vitamin B12 loaded films were prepared by using a water-in-oil emulsion method. The copolymer properties, like permeability, could be varied by increasing the PEG-segment length from 300 up to 4,000 g/mol and by changing the wt% of PEGT. From permeation and release experiments. the diffusion coefficient of vitamin B12 through PEGT/PBT films of different compositions was determined. The diffusion coefficient of Vitamin B12 was strongly dependent on the composition of the copolymers. Although an increased wt% of PEGT (at a constant PEG-segment length) resulted in a higher diffusion coefficient, a major effect was observed at increasing PEG-segment length. By varying the copolymer composition, a complete release of vitamin B12 in 1 day up to a constant release for over 12 weeks was obtained. The release rate could be effectively tailored by blending copolymers with different PEG-segment lengths. The swelling and the crystallinity of the matrix could explain the effect of the matrix composition on the release behavior.

Biocompatible Materials↗

Phase separation and physical properties of PEO-containing poly(ether ester amide)s.

Poly(ether ester amide) (PEEA) copolymers based on poly(ethylene glycol) (PEG), 1,4-butanediol, and dimethyl-7,12-diaza-6,13-dione-1,18-octadecanedioate (a diester-diamide monomer) were synthesized by a two-step polycondensation reaction. The obtained segmented copolymers are hydrophilic, with a water uptake of 24-340%. PEEA copolymers showed microphase separation, as observed by differential scanning calorimetry (DSC). The long spacing determined by small-angle X-ray scattering shows an increase in the hydrophilic domain size with increasing PEO content. By varying the copolymer composition, the E-modulus of PEEA could be varied between 61 and 427 MPa, with tensile strengths ranging from 12 to 39 MPa. The elongation at break can reach values up to 850%. The mechanical properties decrease with the uptake of water. However, PEEAs with a relatively low content of PEO still retain good tensile properties and are, in principle, suitable for biomedical applications.

Biocompatible Materials↗

The different behaviors of skeletal muscle cells and chondrocytes on PEGT/PBT block copolymers are related to the surface properties of the substrate.

The attachment, proliferation, morphology, and differentiation of two cell types-skeletal muscle cells and chondrocytes-were investigated on different compositions of poly(ethylene glycol) and poly(butylene terephthalate) segmented block copolymers. Four weight percentages (40, 55, 60, and 70%) and two different molecular weights (300 and 1000 Da) of poly(ethylene glycol) were tested. Varying the weight percentage and molecular weight of poly(ethylene glycol) resulted in different behaviors for skeletal muscle cells and chondrocytes. The attachment of skeletal muscle was the highest (similar to tissue culture polystyrene) when copolymers containing 55 wt % of poly(ethylene glycol) were used, regardless of the poly(ethylene glycol) molecular weight. Maximum proliferation and differentiation of skeletal muscle cells was achieved when copolymers containing 55 wt % and 300 Da molecular weight of poly(ethylene glycol) were used. In contrast, the weight percentage and molecular weight of poly(ethylene glycol) had no significant effect on chondrocyte attachment and proliferation; the attached chondrocytes retained a differentiated phenotype only when a 70 wt % of poly(ethylene glycol) was used. Cell behavior was correlated with the surface properties of the copolymer films, as indicated by contact-angle measurements. These results suggest that an optimized wt % and molecular weight of poly(ethylene glycol) will be useful depending on the specific cell type.

Animals↗

Antimicrobial effects of positively charged surfaces on adhering Gram-positive and Gram-negative bacteria.

The infection of biomaterials is determined by an interplay of adhesion and surface growth of the infecting organisms. In this study, the antimicrobial effects on adhering bacteria of a positively charged poly(methacrylate) surface (xi potential +12 mV) were compared with those of negatively charged poly(methyl methacrylate) (-12 mV) and a highly negatively charged poly(methacrylate) (-18 mV) surface. Initial adhesion of Staphylococcus aureus ATCC 12600, Staphylococcus epidermidis HBH(2) 102, Escherichia coli O2K2 and Pseudomonas aeruginosa AK1 to these surfaces was measured in a parallel plate flow chamber in phosphate-buffered saline. Adhering bacteria were allowed to multiply by perfusing the flow chamber with growth medium. All bacteria adhered most rapidly to the positively charged surface, but there was no subsequent surface growth of the Gram-negative strains. On the negatively charged surfaces, despite a slower initial adhesion, surface growth of the adhering bacteria was exponential for both Gram-positive and Gram-negative strains. These results suggest that positively charged biomaterial surfaces exert an antimicrobial effect on adhering Gram-negative bacteria, but not on Gram-positive ones.

Bacterial Adhesion↗