PubMed Health⌕ Search

Biomedical subjects

D W Hoeppner

Publications and source records attributed to D W Hoeppner.

4 recordsLinked to original sources

Long-term mechanical circulatory support system reliability recommendation: American Society for Artificial Internal Organs and The Society of Thoracic Surgeons: long-term mechanical circulatory support system reliability recommendation.

Jointly developed by members of the American Society for Artificial Internal Organs and the Society of Thoracic Surgeons along with staff from the Food and Drug Administration, the National Heart, Lung and Blood Institute and other experts, this recommendation describes the reliability considerations and goals for Investigational Device Exemption and Premarket Approval submissions for long-term, mechanical circulatory support systems. The recommendation includes a definition of system failure, a discussion of an appropriate reliability model, a suggested in vitro reliability test plan, reliability considerations for animal implantation tests, in vitro and animal in vivo performance goals, the qualification of design changes during the Investigational Device Exemption clinical trial, the development of a Failure Modes Effects and Criticality Analysis, and the reliability information for surgeons and patient candidates. The document will be periodically reviewed to assess its timeliness and appropriateness within five years.

Animals↗

Effects of surface integrity on the fatigue life of thin flexing membranes.

It has been known for some time that surface integrity has an effect on the fatigue life of metals and "brittle" polymers. In cardiovascular applications of polymeric materials, emphasis is placed on elastomers having extended flexure lifetimes (i.e., fatigue life). The effect of surface integrity on the performance properties of Biomer (Ethicon, Inc, Somerville, NJ) a segmented polyurethane used in many blood contacting devices, is being investigated using uniaxial tensile tests in air at room temperature, and biaxial fatigue tests in deionized water at body temperature. Tensile tests were done using ASTM-D-882: Standard Test Methods for Tensile Properties of Thin Plastic Sheeting. No significant differences were noted in the stress-strain curves for specimens with various surface finishes. Fatigue tests were performed using an apparatus developed to allow for the exposure of thin-sheet polymer specimens to fluid at body temperature, while being biaxially strained. Because no standard test method was available, a test protocol was developed with reference to ASTM-D-671-78: Standard Test Methods for the Flexural Fatigue of Plastics by Constant Amplitude of Force. Stress versus life cycle data for specimens with differing surface finishes are being collected. Results to date suggest fatigue life of thin flexing membranes will decrease with increasing order of surface roughness, and fatigue properties are more sensitive to effects of changes in surface integrity than tensile properties measured by monotonic loading.

Biocompatible Materials↗

Long-term mechanical circulatory support system reliability recommendation: American Society for Artificial Internal Organs and Society of Thoracic Surgeons: long-term mechanical circulatory support system reliability recommendation.

Jointly developed by members of the American Society for Artificial Internal Organs and the Society of Thoracic Surgeons along with staff from the Food and Drug Administration, the National Heart, Lung and Blood Institute and other experts, this recommendation describes the reliability considerations and goals for Investigational Device Exemption and Premarket Approval submissions for long-term, mechanical circulatory support systems. The recommendation includes a definition of system failure, a discussion of an appropriate reliability model, a suggested in vitro reliability test plan, reliability considerations for animal implantation tests, in vitro and animal in vivo performance goals, the qualification of design changes during the Investigational Device Exemption clinical trial, the development of a Failure Modes Effects and Criticality Analysis, and the reliability information for surgeons and patient candidates. The document will be periodically reviewed to assess its timeliness and appropriateness within five years.

Clinical Trials as Topic↗

Device reliability.

Explore the source record for details and available documents.

Artificial Organs↗