D W Holdsworth

Publications and source records attributed to D W Holdsworth.

5 recordsLinked to original sources

Computer-controlled positive displacement pump for physiological flow simulation.

A computer-controlled pump for use both in the study of vascular haemodynamics and in the calibration of clinical devices which measure blood flow is designed. The novel design of this pump incorporates two rack-mounted pistons, driven into opposing cylinders by a micro-stepping motor. This approach allows the production of nearly uninterrupted steady flow, as well as a variety of pulsatile waveforms, including waveforms with reverse flow. The capabilities of this pump to produce steady flow from 0.1 to 60 ml s-1, as well as sinusoidal flow and physiological flow, such as that found in the common femoral and common carotid arteries are demonstrated. Cycle-to-cycle reproducibility is very good, with an average variation of 0.1 ml s-1 over thousands of cycles.

Arteries

Characterisation of mammographic parenchymal pattern by fractal dimension.

A consistent, quantitative, observer-independent method of characterising mammographic parenchymal pattern is described. The method is based on the calculation of the 'fractal dimension' of digitised mammograms. The degree of correlation between the parenchymal pattern classifications by a fractal-based system and those of radiologists is assessed. For a set of 70 mammograms, average weighted proportion agreement among three radiologists in calling Wolfe grades was 85%, while agreement between the radiologists and our fractal classifier was 84%. The method developed may prove to be useful in establishing an index of risk for breast cancer and, ultimately, in determining intervals between examinations for individuals in a mammographic screening programme.

Breast Neoplasms

Computer-controlled flow simulator for MR flow studies.

A novel computer-controlled flow simulator for use in magnetic resonance (MR) flow experiments was evaluated. The accuracy in constant-flow mode was better than 1%. The accuracy in pulsatile-flow mode was found to be dependent on the interconnecting tubing. The short-term and long-term reproducibilities of pulsatile waveforms were less than or equal to 0.4 mL/sec (1 standard deviation). Increased response times due to the lengths of tubing required in MR flow experiments were surmounted by using a modified tubing configuration and precompensated waveforms. Piston reversal was found not to cause major difficulties in MR flow experiments.

Blood Circulation

A time-delay integration charge-coupled device camera for slot-scanned digital radiography.

We have developed a low-noise digital camera based on a 512 x 96 element CCD operating in the time-delay integration mode. This camera has been combined with an x-ray image intensifier to record radiographic images produced by a scanning slot beam of radiation. This results in the rejection of a large fraction of scattered radiation, without a significant increase in x-ray tube heat loading or image acquisition time. Here we describe the design of our CCD camera and the results of our investigations of camera resolution, linearity, noise, and quantum efficiency. We have found that both the resolution limit (50 mm-1) and the dynamic range (2100) of this novel camera are greater than reported values for conventional video cameras. Applications of this system in digital angiography and mammography are discussed.

Angiography

A digital-radiographic technique for in vitro tissue thickness measurement using iodine displacement.

A novel digital radiographic method has been developed for measuring the thickness of a tissue sample by iodine displacement. This simple, accurate method is useful both in medical research and in the comparison of pathological and clinical findings. Radiographic measurements of tissue samples in air suffer from the limitation that the quantity measured depends on the product of both thickness and radiographic attenuation coefficient. This technique allows one to obtain thickness measurements from a digital radiograph of a tissue sample suspended in a bath of radio-opaque contrast agent. The attenuation of the iodinated contrast agent is much higher than that of tissue or calcium. Thus the resulting image is determined largely by the contour of the surrounding bath, and is only slightly influenced by the composition of the tissue. This technique improves both the accuracy and precision of radiographic thickness determination. In this paper the iodine displacement technique is described and the accuracy and precision of thickness measurements in appropriate phantoms are quantified. This technique has been used with both image intensifier and screen-film based imaging systems to obtain thickness maps of calcified human aorta, with precision better than 4% and spatial resolution of 2.5 mm-1.

Aged