4 T MRI of chondrocalcinosis in combination with three-dimensional CT, radiography, and arthroscopy: a report of three cases.

OBJECTIVE: To describe 4 T MRI techniques in imaging chondrocalcinosis within the knee and examine the results together with those demonstrated using three-dimensional (3D) computed tomography, conventional radiography, and arthroscopy. DESIGN AND PATIENTS: From a larger clinical imaging study of early osteoarthritis, knee arthroscopy patients were imaged using high-field MRI and high-resolution 3D CT prior to their surgery. Retrospective review of the imaging data diagnosed three patients with chondrocalcinosis. Fat-suppressed 3D spoiled gradient (3D SPGR) and two-dimensional fat-suppressed fast spin echo (FSE) imaging was performed at 4 T. The MR images, multi-planar reformatted CT (MPR-CT) and maximum intensity projection CT (MIP-CT) images, and radiographs were examined by a musculoskeletal radiologist for the presence and location of chondrocalcinosis. The findings from arthroscopy were also included. RESULTS: MRI showed 16 sites of punctate hypointense regions from 18 articular surfaces and five of six menisci with similar signal characteristics. Both meniscal chondrocalcinosis and meniscal tears were clearly visible using the 3D SPGR sequence. Only three sites were demonstrated to have calcification using MPR-CT and MIP-CT revealed an additional three. In articular cartilage surfaces showing surface disruption, arthroscopy demonstrated 11 sites with crystal deposition. Arthroscopy also revealed five menisci with calcification present. CONCLUSION: Our preliminary findings suggest that imaging chondrocalcinosis using spoiled gradient 4 T MRI is superior and complementary to the other imaging modalities in the detection of crystal deposition in both articular cartilage and menisci.

Adult↗

Fundamental image quality limits for microcomputed tomography in small animals.

Small-animal imaging has become increasingly more important as transgenic and knockout mice are produced to model human diseases. One imaging technique that has emerged is microcomputed tomography (micro-CT). For live-animal imaging, the precision in the images will be determined by the x-ray dose given to the animal. As a result, we propose a simple method to predict the noise performance of an x-ray micro-CT system as a function of dose and image resolution. An ideal, quantum-noise limited micro-CT scanner, assumed to have perfect resolution and ideal efficiency, was modeled. Using a simplified model, the coefficient of variation (COV) of the linear attenuation coefficient was calculated for a range of entrance doses and isotropic voxel sizes. COV calculations were performed for the ideal case and with simulated imperfections in efficiency and resolution. Our model was validated in phantom studies and mouse images were acquired with a specimen scanner to illustrate the results. A simplified model of noise propagation in the case of isotropic resolution indicates that the COV in the linear attenuation coefficient is proportional to (dose)(-1/2) and to the (isotropic voxel size)(-2) in the reconstructed volume. Therefore an improvement in the precision can be achieved only by increasing the isotropic voxel size (thereby decreasing the resolution of the image) or by increasing the x-ray dose. For the ideal scanner, a COV of 1% in the linear attenuation coefficient for an image of a mouse exposed to 0.25 Gy is obtained with a minimum isotropic voxel size of 135 microm. However, the same COV is achieved at a dose of 5.0 Gy with a 65 microm isotropic voxel size. Conversely, for a 68 mm diameter rat, a COV of 1% obtained from an image at 5.0 Gy would require an isotropic voxel size of 100 microm. These results indicate that short-term, potentially lethal, effects of ionizing radiation will limit high-resolution live animal imaging. As improvements in detector technology allow the resolution to improve, by decreasing the detector element size to tens of microns or less, high quality images will be limited by the x-ray dose administered. For the highest quality images, these doses will approach the lethal dose or LD50 for the animals. Approaching the lethal dose will affect the way experiments are planned, and may reduce opportunities for experiments involving imaging the same animal over time. Dose considerations will become much more important for live small-animal imaging as the limits of resolution are tested.

Animals↗

In vitro investigation of calcium distribution and tissue thickness in the human thoracic aorta.

Atherosclerosis represents a significant cause of morbidity and mortality in the western world. Manifestations of atherosclerotic disease among the elderly include the development of raised lesions that often include calcified regions with material properties similar to bone. There is little information available about the amount and distribution of these calcified plaques within the human aorta, partly due to the difficulty in obtaining this information during in vivo studies. We report the results of a cadaveric investigation of thoracic aortic wall thickness, diameter and calcium content. A non-destructive x-ray imaging technique was used to obtain two-dimensional maps of total thickness and mineral content in excised thoracic aortic specimens. In a study of 39 individuals (23 male and 16 female, aged 20-92 years) we report a significant non-linear correlation between calcium burden and age, with calcium deposition most commonly occurring proximal to the ostia of major branching vessels. We also found a significant linear correlation between age and both total aortic wall thickness and aortic diameter. An improved understanding of the pathological changes in the ageing thoracic aorta may be useful in the development of strategies to reduce the undesirable vessel calcification associated with atherosclerosis.

Adult↗

The stimulation of vertebral and tibial bone growth by the parathyroid hormone fragments, hPTH-(1-31)NH2, [Leu27]cyclo(Glu22-Lys26)hPTH-(1-31)NH2, and hPTH-(1-30)NH2.

The native human parathyroid hormone, hPTH-(1-84), and certain carboxyl truncated analogs such as hPTH-(1-34) and even smaller fragments such as hPTH-(1-31)NH2, [Leu27]cyclo(Glu22-Lys26)hPTH-(1-31)NH2, and hPTH-(1-30)NH2 stimulate femoral trabecular and cortical bone growth in ovariectomized (OVX) rats. Here we show that when injected once daily for 6 weeks starting 2 weeks after OVX in doses of 1 or 2 nmol/100 g of body weight, hPTH-(1-31)NH2, [Leu27] cyclo(Glu22-Lys26)hPTH-(1-31)NH2, and hPTH-(1-34)NH2 prevented the loss of trabecular volume in the L5 vertebrae induced by OVX. In fact, by the end of the sixth week of injections (i.e., the eighth week after OVX) the fragments had increased the volume and trabecular thickness significantly above the values in vehicle-injected sham-operated rats. hPTH-(1-30)NH2 can stimulate vertebral bone growth as much as the larger fragments, but 10-25 times more of it was needed to do so. The same daily doses of hPTH-(1-31)NH2, [Leu27]cyclo(Glu22-Lys26)hPTH-(1-31)NH2, and hPTH-(1-34)NH2 also raised the trabecular volume and thickness in the L5 vertebrae of rats well above the values in vehicle-treated animals when the injections were started 9 weeks after OVX. This restoration of trabecular bone in the L5 vertebrae in estrogen-deprived animals was accompanied by a significant increase in the bone mineral density (BMD) of the L1-L4 vertebrae and tibias. However, there was no significant drop in the pelvic BMD in the estrogen-deprived animals and the effects of hPTH-(1-31)NH2, [Leu27]cyclo(Glu22-(Lys) hPTH-(1-31)NH2, and hPTH-(1-34)NH2 on the pelvic BMD were equivocal.

Animals↗

The radiographic quantitation of aortic valve calcification: implications for assessing bioprosthetic valve calcification in vitro.

Calcification of natural aortic and bioprosthetic heart valves is a poorly understood phenomenon that results in valvular obstruction and tissue failure. We describe a non-destructive quantitative computed microtomographic (QCT) technique for determining both calcium content and local calcium distribution within explanted valves. As a reference standard, a dual-energy x-ray absorptiometry (DEXA) system with an accuracy demonstrated to be within 1% of the true calcium mass of test material was used to obtain the total calcium content of 24 human aortic valve cusps recovered at autopsy from patients aged 51-80 years. These cusps were then scanned using our unique volume QCT scanner, with multiple x-ray projections acquired by rotating the explanted tissue through a single axis of rotation. A three-dimensional cross-sectional map was reconstructed for each cusp. Voxel size was 0.003 mm3 and a calibration phantom was used to calculate calcium content. The minimum detection limit for calcium mass was 1 mg within the whole cusp. The DEXA and QCT scans were compared with respect to total calcium content, which ranged from 0 to 15 mg. An excellent correlation between the two independent techniques was demonstrated with an r2 value of 0.94 (p < 0.001). Non-destructive microtomographic CT scanning provided excellent volumetric density measurements, with quantitative 3D images permitting an assessment of any individual area of the cusp for calcium content and spatial distribution. This new approach to valve tissue analysis allows for subsequent histologic assessment.

Absorptiometry, Photon↗

Flow patterns at the stenosed carotid bifurcation: effect of concentric versus eccentric stenosis.

Carotid stenosis severity is a commonly used indicator for assessing risk of stroke. However, the majority of individuals with severe carotid artery disease never suffer a stroke, and strokes can occur even with only mild or moderate stenosis. This suggests local factors (other than stenosis severity) at or near the carotid artery bifurcation may be important in determining stroke risk. In this paper we investigate the effect of stenosis geometry on flow patterns in the stenosed carotid bifurcation, using concentrically and eccentrically stenosed anthropomorphic carotid bifurcation models having identical stenosis severity. Computational simulations and experimental flow visualizations both demonstrate marked differences in flow patterns of concentric and eccentric stenosis models for moderately and severely stenosed cases, respectively. In particular, we identify post-stenotic recirculation zone size and location, and spatial extent of elevated wall shear stress as key factors differing between the two geometries. As these are also rotid plaque more vulnerable to cerebral embolus prokey biophysical factors promoting thrombogenesis, we propose that the stenosed carotid bifurcation geometry--or the induced flow patterns themselves--may provide more specific indicators for those plaques that are vulnerable to enhanced thromboembolic potential, and hence, increased risk of ischemic stroke.

Biomedical Engineering↗

Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: image-based correction of gantry motion nonidealities.

The image quality of 3D reconstructions produced using a C-arm mounted XRII depends on precise determination of the geometric parameters that describe the detector system in the laboratory frame of reference. We have designed a simplified calibration system that depends on images of a metal sphere, acquired during rotation of the gantry through 200 degrees. Angle-dependent shift corrections are obtained, accounting for nonideal motion in two directions: perpendicular to the axis of rotation and tangential to the circular trajectory (tau), and parallel to the axis of rotation (xi). Projection images are corrected prior to reconstruction using a simple shift-interpolation algorithm. We show that the motion of the gantry is highly reproducible during acquisitions within one day (mean standard deviation in tau and xi is 0.11 mm and 0.08 mm, respectively), and over 21 months (mean standard deviation in tau and xi is 0.10 mm and 0.06 mm, respectively). Reconstruction of a small-bead phantom demonstrates uniformity of the correction algorithm over the full volume of the reconstruction [standard deviation of full-width-half-maximum of the beads is approximately 0.25 pixels (0.13 mm) over the volume of reconstruction]. Our approach provides a simple correction technique that can be applied when trajectory deviations are significant relative to the pixel size of the detector but small relative to the detector field of view, and when the fan angle of the acquisition geometry is small (<20 degrees). A comparison with other calibration techniques in the literature is provided.

Algorithms↗

Bone mineral measurement of phalanges: comparison of radiographic absorptiometry and area dual X-ray absorptiometry.

With a standard, image-intensifier-based, digital radiographic system, high-spatial-resolution images of the hand were acquired for analysis of phalangeal bone mineral density with dual x-ray absorptiometry (DXA). Results with phalangeal DXA had precision of plus or minus 0.67% and accuracy of 4.1% and correlated well with those with radiographic absorptiometry. This phalangeal DXA technique is potentially useful for clinical diagnosis of osteoporosis.

Absorptiometry, Photon↗

Rapid small-animal dual-energy X-ray absorptiometry using digital radiography.

Although dual-energy X-ray absorptiometry (DEXA) is an established technique for clinical assessment of areal bone mineral density (BMD), the spatial resolution, signal-to-noise ratio, scan time, and availability of clinical DEXA systems may be limiting factors for small-animal investigations using a large number of specimens. To avoid these limitations, we have implemented a clinical digital radiography system to perform rapid area DEXA analysis on in vitro rat bone specimens. A crossed step-wedge (comprised of epoxy-based materials that mimic the radiographic properties of tissue and bone) was used to calibrate the system. Digital radiographs of bone specimens (pelvis, spine, femur, and tibia from sham-ovariectomized [SHAM] and ovariectomized [OVX] rats) were obtained at 40 kilovolt peak (kVp) and 125 kVp, and the resulting areal BMD values were compared with those obtained with a clinical fan-beam DEXA system (Hologics QDR 4500). Our investigation indicates that the cross-wedge calibrated (CWC) DEXA technique provides high-precision measurements of bone mineral content (BMC; CV = 0.6%) and BMD (CV = 0.8%) within a short acquisition time (<30 s). Areal BMD measurements reported by the CWC-DEXA system are within 8.5% of those reported by a clinical fan-beam scanner, and BMC values are within 5% of the known value of test specimens. In an in vivo application, the CWC-DEXA system is capable of reporting significant differences between study groups (SHAM and OVX) that are not reported by a clinical fan-beam DEXA system, because of the reduced variance and improved object segmentation provided by the CWC-DEXA system.

Absorptiometry, Photon↗

Anthropomorphic carotid bifurcation phantom for MRI applications.

Anthropomorphic carotid bifurcation flow phantoms that incorporate different stenotic geometries within the internal carotid artery have been developed. This technique produces high-fidelity, life-size vascular flow models that are compatible with magnetic resonance techniques. The models, in conjunction with a computer-controlled flow pump, address the need for a complex vascular geometry that can be used to verify magnetic resonance angiography (MRA) techniques that quantify stenosis severity and blood flow. Stenotic geometries, with up to 80% diameter reduction, have been fabricated in two different phantom materials. Plastic phantoms provide a durable, rigid geometry where the absolute dimensions of the model are well known. Agar gel phantoms provide tissue-like signal (T1, T2) up to the lumen boundary and are also compatible with ultrasound techniques. In this paper the technique to produce vascular flow phantoms is outlined and the compatibility of these phantoms with MRA techniques is demonstrated. J. Magn. Reson. Imaging 1999;10:533-544.

Carotid Arteries↗

Application of dynamic computed tomography for measurements of local aortic elastic modulus.

A novel computed tomographic (CT) technique used for the instantaneous measurement of the dynamic elastic modulus of intact excised porcine aortic vessels subjected to physiological pressure waveforms is described. This system was comprised of a high resolution X-ray image intensifier based computed tomographic system with limiting spatial resolution of 3.2 mm-1 (for a 40 mm field of view) and a computer-controlled flow simulator. Utilising cardiac gating and computer control, a time-resolved sequence of 1 mm thick axial tomographic slices was obtained for porcine aortic specimens during one simulated cardiac cycle. With an image acquisition sampling interval of 16.5 ms, the time sequences of CT slices were able to quantify the expansion and contraction of the aortic wall during each phase of the cardiac cycle. Through superficial tagging of the adventitial surface of the specimens with wire markers, measurement of wall strain in specific circumferential sectors and subsequent calculations of localised dynamic elastic modulus were possible. The precision of circumferential measurements made from the CT images utilising a cluster-growing segmentation technique was approximately +/- 0.25 mm and allowed determination of the dynamic elastic modulus E(dyn) with a precision of +/- 8 kPa. Dynamic elastic modulus was resolved as a function of the harmonics of the physiological pressure waveform and as a function of the angular position around the vessel circumference. Application of this dynamic CT (DCT) technique to seven porcine thoracic aortic specimens produced a circumferential average (over all frequency components) E(dyn) of 373 +/- 29 kPa. This value was not statistically different (p < 0.05) from the values of 430 +/- 77 and 390 +/- 47 kPa obtained by uniaxial tensile testing and volumetric measurements respectively.

Animals↗

An investigation of the flow dependence of temperature gradients near large vessels during steady state and transient tissue heating.

Temperature distributions measured during thermal therapy are a major prognostic factor of the efficacy and success of the procedure. Thermal models are used to predict the temperature elevation of tissues during heating. Theoretical work has shown that blood flow through large blood vessels plays an important role in determining temperature profiles of heated tissues. In this paper, an experimental investigation of the effects of large vessels on the temperature distribution of heated tissue is performed. The blood flow dependence of steady state and transient temperature profiles created by a cylindrical conductive heat source and an ultrasound transducer were examined using a fixed porcine kidney as a flow model. In the transient experiments, a 20 s pulse of hot water, 30 degrees C above ambient, heated the tissues. Temperatures were measured at selected locations in steps of 0.1 mm. It was observed that vessels could either heat or cool tissues depending on the orientation of the vascular geometry with respect to the heat source and that these effects are a function of flow rate through the vessels. Temperature gradients of 6 degrees C mm(-1) close to large vessels were routinely measured. Furthermore, it was observed that the temperature gradients caused by large vessels depended on whether the heating source was highly localized (i.e. a hot needle) or more distributed (i.e. external ultrasound). The gradients measured near large vessels during localized heating were between two and three times greater than the gradients measured during ultrasound heating at the same location, for comparable flows. Moreover, these gradients were more sensitive to flow variations for the localized needle heating. X-ray computed tomography data of the kidney vasculature were in good spatial agreement with the locations of all of the temperature variations measured. The three dimensional vessel path observed could account for the complex features of the temperature profiles. The flow dependences of the transient temperature profiles near large vessels during the pulsed experiments were consistent with the temperature distributions measured in the steady state experiments and provided unique insights into the process of convective heat transfer in tissues. Finally, it was shown that even for very short treatment times (3-20 s), large vessels had significant effects on the tissue temperature distributions.

Angiography↗

Characterization of common carotid artery blood-flow waveforms in normal human subjects.

Knowledge of human blood-flow waveforms is required for in vitro investigations and numerical modelling. Parameters of interest include: velocity and flow waveform shapes, inter- and intra-subject variability and frequency content. We characterized the blood-velocity waveforms in the left and right common carotid arteries (CCAs) of 17 normal volunteers (24 to 34 years), analysing 3560 cardiac cycles in total. Instantaneous peak-velocity (Vpeak) measurements were obtained using pulsed-Doppler ultrasound with simultaneous collection of ECG data. An archetypal Vpeak waveform was created using velocity and timing parameters at waveform feature points. We report the following timing (post-R-wave) and peak-velocity parameters: cardiac interbeat interval (T(RR)) = 0.917 s (intra-subject standard deviation = +/- 0.045 s); cycle-averaged peak-velocity (V(CYC)) = 38.8 cm s(-1) (+/-1.5 cm s(-1)); maximum systolic Vpeak = 108.2 cm s(-1) (+/-3.8 cm s(-1)) at 0.152 s (+/-0.008 s); dicrotic notch Vpeak = 19.4 cm s(-1) (+/-2.9 cm s(-1)) at 0.398 s (+/-0.007 s). Frequency components below 12 Hz constituted 95% of the amplitude spectrum. Flow waveforms were computed from Vpeak by analytical solution of Womersley flow conditions (derived mean flow = 6.0 ml s(-1)). We propose that realistic, pseudo-random flow waveform sequences can be generated for experimental studies by varying, from cycle to cycle, only T(RR) and V(CYC) of a single archetypal waveform.

Adult↗

Techniques to alleviate the effects of view aliasing artifacts in computed tomography.

Due to practical limitations in data acquisition, 3-D computed tomography systems must attempt to provide rapid reconstructions of acceptable quality from a limited number of views. The use of convolution backprojection (CBP) for image reconstruction from an inadequate number of projections, results in view aliasing artifacts. In this paper we investigate different post-processing methods of alleviating the effects of view aliasing artifacts. Two distinct methods and their variants are considered. The first, termed the intermediate view reprojection (IVR) method, involves estimating a set of intermediate views by reprojection, followed by a reconstruction using the augmented set of views. The second, termed the error-correction (EC) method, incorporates a correction on the initial reconstruction based on the projection-domain error. Suitable modifications and variants of the above methods are indicated. Of the methods discussed, the IVR method is simple, tends to reduce the effects of artifacts with less susceptibility to secondary effects, and is applicable to region-of-interest reconstructions.

Algorithms↗

A three-dimensional cerebrovascular flow phantom.

We have constructed a life-sized fully three-dimensional (3D) rigid flow-through model of the cerebral vasculature. Average vessel diameters and lengths, taken from published values in the literature, were used to describe the geometry of our phantom; numerically controlled machining techniques were used to fabricate the model. Inflow to the phantom is provided through two internal carotid arteries and two vertebral arteries. Outflow is provided through the anterior cerebral arteries, the middle cerebral arteries, and the posterior cerebral arteries. The phantom includes the circle of Willis, and aneurysms of variable size may be attached at different locations. We have tested the model for geometric accuracy using high-resolution MR and CT imaging protocols, and have found that measured and prescribed diameters agree to within better than 4%. Flow dynamics, including waveform shape and flow division between branches, also mimic that seen in vivo, with flows within 16% (on average) of the prescribed values. We present 3D magnetic resonance angiography, digital subtraction angiography, and computed rotational angiography images of the phantom under conditions that mimic physiological situations.

Angiography, Digital Subtraction↗

Quantitative angiographic blood-flow measurement using pulsed intra-arterial injection.

A technique for quantitative blood-flow measurement using a novel pulsed injection of radiographic contrast agent is reported. A pressurized source of contrast agent is interrupted by a rotary valve at rates ranging from 1 to 30 Hz, producing well-defined boli at the end of a catheter. The position of these boli can be recorded by a digital radiographic system and analyzed by one of several previously reported techniques, to produce quantitative measurements of blood velocity and flow rate throughout the cardiac cycle. The contrast-agent flow wave form produced by the pulsed injector has been measured with an electromagnetic flow meter, for driving pressures ranging from 600 to 1500 kPa. Excellent modulation of the contrast agent is observed for injection frequencies up to 20 Hz, through catheters up to 100 cm in length. Preliminary in vitro angiographic flow measurements have been performed using an x-ray image intensifier, coupled to a linear photodiode array as the digital detector. Both constant flow and pulsatile human blood-flow wave forms were simulated within a 6.4-mm-diam straight tube and monitored with an electromagnetic flow meter. These experiments indicate that the pulsed injector can be used to provide estimates of arterial blood flow over the entire cardiac cycle (including reverse flow), to within about +/-11%, following injection of less than 10 ml of iodinated contrast agent.

Angiography, Digital Subtraction↗

Elastic response of human iliac arteries in-vitro to balloon angioplasty using high-resolution CT.

Previous angioplasty studies have used angiography and intravascular ultrasound to obtain vascular dimensions. These imaging methods do not always provide reliable measurements due to limitations in image orientation and resolution. In this study, high-resolution (0.1 x 0.1 x 0.5 mm) transverse CT slices were obtained from human common-iliac arteries in vitro to study their elastic response pre- and post-angioplasty. Seven iliacs from five patients were imaged over the physiological pressure range both pre- and post-angioplasty. Contrast was obtained with humidified air surrounding the artery. Angioplasty was done with 10 or 12 mm diameter Medi-Tech balloon catheters with a balloon pressure of 300 kPa held for 30 s. Lumen circumference, c, measured from the images, was plotted against pressure, P, and curve fitting showed c = A(1 - e(-KP)) + B where A, K, and B are fitting parameters. Six lesions appeared soft and were compressed, while one was calcified and partially lifted off the wall. Normalized changes in parameters B and K were much higher post-angioplasty in the calcified lesion, and were over 3 standard deviations from the means of the normalized changes in the six compressed lesions. Balloon/stenosed lumen diameter ratios greater than 1.2 produced a lumen area increase of 38.6 +/- 4.1%(S.D.)(n = 3); ratios less than 1.2 produced an increase of 4.4 +/- 5.1%(S.D.)(n = 4). There was no correlation between area increase and balloon/normal lumen diameter ratio (the value used clinically). Arteries with lesions containing stiffer plaques that tear from the artery wall during angioplasty appear more distensible over the physiological pressure range post-angioplasty.

Aged↗

The effect of storage time and repeated measurements on the elastic properties of isolated porcine aortas using high resolution x-ray CT.

A Laboratory CT scanner with a resolution of (0.1 mm)3 was used to determine if storage up to 7 days in saline at 4 degrees C and (or) repeated measurements would alter the compliance, C, and incremental elastic modulus, Einc, of isolated porcine aortas. All specimens were obtained fresh, made pressure-tight, and then mounted in the scanner, with humidified air used to produce adequate x-ray contrast. The specimens were imaged at pressures of 4, 8, 12, 16, 20, and 24 kPa, and vessel measurements were then obtained with a computerized technique and analyzed. Seven thoracic aortas were studied on days 0, 3, 5, and 7, with a significant change (p < 0.05) in compliance first occurring after three imaging studies (i.e., day 5). Compliance of the fresh thoracic aortas (mean +/- SD) was 0.90 +/- 0.28 mm/kPa at 14.4 kPa and 0.85 +/- 0.31 mm/kPa at 22.5 kPa. Six thoracic aortas were studied only on days 0 and 6 with no intermediate measurements. They showed no change in either compliance (0.88 +/- 0.07 mm/kPa at 14.4 kPa and 0.64 +/- 0.09 mm/kPa at 22.5 kPa) or Einc (0.46 +/- 0.05 MPa at 14.4 kPa and 0.88 +/- 0.15 MPa at 22.5 kPa) from day 0 to day 6. Thus, number of measurements rather than time appears to be the important factor. Six abdominal aortas were studied similarly but on days 0, 3, and 6. No significant change occurred in compliance (0.15 +/- 0.06 mm/kPa at 14.4 kPa and 0.032 +/- 0.026 mm/kPa at 22.5 kPa) but Einc showed a change, possibly due to their viscoelastic properties. We conclude that this nondestructive CT measurement method is suitable for repeated studies on porcine thoracic aortas, but not abdominal aortas, if the measurement involves two consecutive imaging sessions separated by no more than 6 days.

Animals↗