PubMed Health⌕ Search

Biomedical subjects

D W Kaczka

Publications and source records attributed to D W Kaczka.

10 recordsLinked to original sources

Airway constriction pattern is a central component of asthma severity: the role of deep inspirations.

Measurements of lung resistance and elastance (RL and EL) from 0.1 to 8 Hz reflect both the mean level and pattern of lung constriction. The goal of this study was to establish a relation between a deep inspiration (DI) and the heterogeneity of constriction in healthy versus asthmatic subjects. Constriction pattern was assessed from measurements of the RL and EL from 0.1 to 8 Hz in seven healthy subjects and in 12 asthmatics. These data were acquired before and after a DI and before and after a standard methacholine challenge versus a modified challenge in which a DI is prohibited. Generally, avoidance of a DI increased responsiveness. In healthy subjects and in those with mild-to-moderate baseline asthma a bronchial challenge, especially during self-inhibited DI, produced a heterogenous pattern of constriction inclusive of randomly distributed airway closures or near closures. Nevertheless, such subjects were able to reopen their airways via a DI. In contrast, in subjects with severe baseline asthma, there is a more extreme heterogeneous constriction pattern with random airway closures even at baseline. Further, there is no residual bronchodilatory effect of a DI either before or after bronchial challenge. We conjecture that inflammation and wall-remodeling facilitate a dangerous degree of heterogeneous constriction inclusive of airway closures or near closures, and contribute to the prevention of a DI from having a residual bronchodilatory effect.

Adolescent↗

Inspiratory lung impedance in COPD: effects of PEEP and immediate impact of lung volume reduction surgery.

Frequency-dependent characteristics of lung resistance (RL) and elastance (EL) are sensitive to different patterns of airway obstruction. We used an enhanced ventilator waveform (EVW) to measure inspiratory RL and EL spectra in ventilated patients during thoracic surgery. The EVW delivers an inspiratory flow waveform with enhanced spectral excitation from 0.156 to 8.1 Hz. Estimates of the coefficients in a trigonometric approximation of the EVW flow and transpulmonary pressure inspirations yielded inspiratory RL and EL spectra. We applied the EVW in a group with mild obstruction undergoing various thoracoscopic procedures (n = 6), and another group with severe chronic obstructive pulmonary disease undergoing lung volume reduction surgery (n = 8). Measurements were made at positive end-expiratory pressure (PEEP) of 0, 3, and 6 cmH(2)O. Inspiratory RL was similar in both groups despite marked differences in spirometry. The chronic obstructive pulmonary disease patients demonstrated a pronounced frequency-dependent increase in inspiratory EL consistent with severe heterogeneous peripheral airway obstruction. PEEP appears to have beneficial effects by reducing peripheral airway resistance. Lung volume reduction surgery resulted in increased inspiratory RL and EL at all frequencies and PEEPs, possibly due to loss of diseased lung tissue, pulmonary edema, increased mechanical heterogeneity, and/or an improvement in airway tethering.

Adult↗

Airway and lung tissue mechanics in asthma. Effects of albuterol.

We examined the partitioning of total lung resistance (RL) into airway resistance (Raw) and tissue resistance (Rti) in patients with mild to moderate asthma (baseline FEV1, 54 to 91% of predicted) before and after albuterol inhalation. An optimal ventilator waveform was used to measure RL and lung elastance (EL) in 21 asthmatics from approximately 0.1 to 8 Hz during tidal excursions. Analysis of the RL and EL provided separate estimates of airway and lung tissue properties. Eleven subjects, classified as Type A asthmatics, displayed slightly elevated RL but normal EL. Their data were well described with a model consisting of homogeneous airways leading to viscoelastic tissues before and after albuterol. The other 10 subjects, classified as Type B asthmatics, demonstrated highly elevated RL and an EL that became highly elevated at frequencies above 2 Hz. These subjects required the inclusion of an airway wall compliance in the model prealbuterol but not postalbuterol. This suggests that the Type B subjects were experiencing pronounced constriction in the periphery of the lung, resulting in shunting of flow into the airway walls. Spirometric data were consistent with higher constriction in Type B subjects. Both groups demonstrated significant (p < 0.05) decreases in Raw and tissue damping after albuterol, but tissue elastance decreased only in the Type B group. The percent contributions of Raw and Rti to RL were similar in both groups and did not change after albuterol. We conclude that in asthma, Raw comprises the majority (> 70%) of RL at breathing frequencies. The relative contributions of Raw and Rti to RL appear to be independent of the degree of smooth muscle constriction.

Administration, Inhalation↗

Relation between preoperative inspiratory lung resistance and the outcome of lung-volume-reduction surgery for emphysema.

BACKGROUND: Surgery to reduce lung volume has recently been reintroduced to alleviate dyspnea and improve exercise tolerance in selected patients with emphysema. A reliable means of identifying patients who are likely to benefit from this surgery is needed. METHODS: We measured lung resistance during inspiration, static recoil pressure at total lung capacity, static lung compliance, expiratory flow rates, and lung volumes in 29 patients with chronic obstructive lung disease before lung-volume-reduction surgery. The changes in the forced expiratory volume in one second (FEV1) six months after surgery were related to the preoperatively determined physiologic measures. A response to surgery was defined as an increase in the FEV1 of at least 0.2 liter and of at least 12 percent above base-line values. RESULTS: Of the 29 patients, 23 had some improvement in FEV1 including 15 who met the criteria for a response to surgery. Among the variables considered, only preoperative lung resistance during inspiration predicted changes in expiratory flow rates after surgery. Inspiratory lung resistance correlated significantly and inversely with improvement in FEV1 after surgery (r=-0.63, P<0.001). A preoperative criterion of an inspiratory resistance of 10 cm of water per liter per second had a sensitivity of 88 percent (14 of 16 patients) and a specificity of 92 percent (12 of 13 patients) in identifying patients who were likely to have a response to surgery. CONCLUSIONS: Preoperative lung resistance during inspiration appears to be a useful measure for selecting patients with emphysema for lung-volume-reduction surgery.

Adult↗

Partitioning airway and lung tissue resistances in humans: effects of bronchoconstriction.

The contribution of airway resistance (Raw) and tissue resistance (Rti) to total lung resistance (RL) during breathing in humans is poorly understood. We have recently developed a method for separating Raw and Rti from measurements of RL and lung elastance (EL) alone. In nine healthy, awake subjects, we applied a broad-band optimal ventilator waveform (OVW) with energy between 0.156 and 8.1 Hz that simultaneously provides tidal ventilation. In four of the subjects, data were acquired before and during a methacholine (MCh)-bronchoconstricted challenge. The RL and EL data were first analyzed by using a model with a homogeneous airway compartment leading to a viscoelastic tissue compartment consisting of tissue damping and elastance parameters. Our OVW-based estimates of Raw correlated well with estimates obtained by using standard plethysmography and were responsive to MCh-induced bronchoconstriction. Our data suggest that Rti comprises approximately 40% of total RL at typical breathing frequencies, which corresponds to approximately 60% of intrathoracic RL. During mild MCh-induced bronchoconstriction, Raw accounts for most of the increase in RL. At high doses of MCh, there was a substantial increase in RL at all frequencies and in EL at higher frequencies. Our analysis showed that both Raw and Rti increase, but most of the increase is due to Raw. The data also suggest that widespread peripheral constriction causes airway wall shunting to produce additional frequency dependence in EL.

Adult↗

Influence of waveform and analysis technique on lung and chest wall properties.

To test an approach for measuring respiratory system resistance (R) and elastance (E) during non-sinusoidal forcing, we measured airway and esophageal pressures and flow at the trachea of 9 anesthetized-paralyzed dogs during sinusoidal forcing (SF) and 4 types of non-sinusoidal forcings at 0.15 and 0.6 Hz and 300 ml tidal volume. During SF, calculations of E and R of the lungs, chest wall or total system from discrete Fourier transform (DFT) and two other widely used methods (multiple regression and volume-pressure loop analysis) did not differ from each other (P > 0.05). During forcing with sinusoidal or step inspiration with passive expiration (inspiratory to expiratory ratio, I/E, = 1:1), Es from any analysis method were within 10% of values during SF. Although Rs of the lungs, chest wall or total system were not affected by waveform shape with DFT (P > 0.05), the other analysis methods gave values for R during non-SF that differed (P < 0.05) from those during SF by up to 77%. If I/E was changed to 1:2, with or without an added 10% inspiratory pause, values for E and R differed least from values during SF if DFT was used. During severe pulmonary edema induced by infusion of oleic acid in the right atrium, results for lung properties were similar to controls, despite large increases in E and R of the lungs. We conclude that E and R of the lungs and chest wall can be measured by DFT using nonsinusoidal forcing waveforms available on most clinical ventilators, incurring only modest error.

Airway Resistance↗

Optimal ventilation waveforms for estimating low-frequency respiratory impedance.

We present a broad-band optimal ventilator waveform (OVW), the concept of which was to create a computer-driven ventilator waveform containing increased energy at specific frequencies (f). Values of f were chosen such that nonlinear harmonic distortion and intermodulation were minimized. The phases at each f were then optimized such that the resulting flow waveform delivered sufficient volume to maintain gas exchange while minimizing peak-to-peak airway opening pressure. Simulations with a linear anatomically consistent branching airway model and a nonlinear viscoelastic model showed that respiratory resistance (Rrs) and elastance (Ers) estimates at 0.1-2 Hz from the OVW are far superior to those from a standard step ventilator waveform (SVW) during healthy and obstructed conditions and that the OVW reduces the influences of harmonic interactions. Using a servo-controlled oscillator, we applied individual sine waves, an OVW containing energy at 0.15625-2.4 Hz, and an SVW to healthy humans and one symptomatic asthmatic subject before and after bronchodilation. The OVW was markedly superior to the SVW and always provided smooth estimates of Rrs and Ers. Before bronchodilation in the asthmatic subject Rrs was highly elevated and Ers was markedly increased with f; after bronchodilation the level of Rrs and the f dependence of Ers decreased. Although based on results from only one asthmatic subject, these data suggest a dominant influence of airway constriction and lung inhomogeneities during asthmatic bronchoconstriction that is alleviated by bronchodilators. These and other results indicate that the OVW approach has high potential for simultaneously probing f and amplitude dependence in the mechanical properties of clinical subjects during physiological breathing conditions and perhaps during dynamic bronchoconstriction.

Adult↗

Low-frequency respiratory mechanics using ventilator-driven forced oscillations.

We evaluated the potential for using a fast Fourier transform (FFT) analysis applied to a standard ventilator waveform to estimate (< 2 Hz) frequency dependence of respiratory or lung resistance (R) and elastance (E). In four healthy humans we measured pressure and flow at the airway opening while applying sine wave forcing from 0.2 to 0.6 Hz at two tidal volumes (VT; 250 and 500 ml). We then applied a step inspiratory ventilator flow wave with relaxed expiration at the same VT and only 0.2 Hz. Step waveform data were also acquired from nine mechanically ventilated patients under intensive care unit conditions. Finally, we simultaneously measured total respiratory (rs), lung (L), and chest wall (cw) impedance data from two dogs (0.156-2 Hz) before and after severe pulmonary edema. Rrs and Ers were estimated by the FFT approach. Humans displayed a small frequency dependence in Rrs and Ers from 0.2 to 0.6 Hz, and both Rrs and Ers decreased at the higher VT. The spectral estimates of Rrs and Ers with the step ventilator wave were often qualitatively comparable to sine wave results below 0.6 Hz but became extremely erratic above the third harmonic. Conversely, in dogs the step wave produced reliable and stable estimates up to 2 Hz in all conditions. Nevertheless, Ecw and Ers still displayed clear and correlated oscillations with increasing frequency, whereas EL showed none. This suggests that nonlinear processes, most likely at the chest wall, contribute to periodic-like fluctuations in respiratory mechanical properties when estimated by applying FFT to a step ventilator wave. Moreover, in humans, but not dogs, a ventilator flow cycle contains insufficient signal energy beyond the third harmonic. We show that the amount of energy available at higher frequencies is largely governed by the mechanical time constant contributing to passive expiratory flow. In dogs the shorter time constant contributes to increased energy. In essence, the frequency content of the flow is subject dependent, and this is not a desirable situation for controlling the quality of the impedance spectra available from a standard ventilator wave.

Adult↗

Assessment of time-domain analyses for estimation of low-frequency respiratory mechanical properties and impedance spectra.

Time-domain estimation has been invoked for tracking of respiratory mechanical properties using primarily a simple single-compartment model containing a series resistance (Rrs) and elastance (Ers). However, owing to the viscoelastic properties of respiratory tissues, Rrs and Ers exhibit frequency dependence below 2 Hz. The goal of this study was to investigate the bias and statistical accuracy of various time-domain approaches with respect to model properties, as well as the estimated impedance spectra. Particular emphasis was placed on establishing the tracking capability using a standard step ventilation. A simulation study compared continuous-time versus discrete-time approaches for both the single-compartment and two-compartment models. Data were acquired in four healthy humans and two dogs before and after induced severe pulmonary edema while applying sinusoidal and standard ventilator forcing. Rrs and Ers were estimated either by the standard Fast Fourier Transform (FFT) approach or by a time-domain least square estimation. Results show that the continuous-time model form produced the least bias and smallest parameter uncertainty for a single-compartment analysis and is quite amenable for reliable on-line tracking. The discrete-time approach exhibits large uncertainty and bias, particularly with increasing noise in the flow data. In humans, the time-domain approach produced smooth estimates of Rrs and Ers spectra, but they were statistically unreliable at the lower frequencies. In dogs, both the FFT and time-domain analysis produced reliable and stable estimates for Rrs or Ers spectra for frequencies out to 2 Hz in all conditions. Nevertheless, obtaining stable on-line parameter estimates for the two-compartment viscoelastic models remained difficult. We conclude that time-domain analysis of respiratory mechanics should invoke a continuous-time model form.

Animals↗

Technique to determine inspiratory impedance during mechanical ventilation: implications for flow limited patients.

We present the design of an enhanced ventilator waveform (EVW) for routine measurement of inspiratory resistance (R) and elastance (E) spectra in ventilator-dependent and/or severely obstructed flow-limited patients. The EVW delivers an inspiratory tidal volume of fresh gas with a flow pattern consisting of multiple sinusoids from 0.156 to 8.1 Hz and permits a patient-driven exhalation to the atmosphere or positive end-expiratory pressure. Weighted least-squares estimates of the coefficients in a sinusoidal series approximation of the EVW inspirations yielded inspiratory R and E spectra. We first validated the EVW approach using simulated pressure and flow data under different physiological conditions, noise levels, and harmonic distortions. We then applied the EVW in four intubated patients during anesthesia and paralysis: two with mild airway obstruction and two with severe emphysema and flow limitation. While the level of inspiratory R was similar in both groups of patients, the inspiratory E of the emphysematous patients demonstrated a pronounced frequency-dependent increase consistent with severe peripheral airway obstruction. We conclude that the EVW offers a potentially practical and efficient approach to monitor lung function in ventilator-dependent patients, especially those with expiratory flow limitation.

Airway Resistance↗