PubMed Health⌕ Search

Biomedical subjects

D W L Hukins

Publications and source records attributed to D W L Hukins.

At least 19 recordsLinked to original sources

Determination of the pressure required to cause mitral valve failure.

A method has been developed for applying water pressure to a closed mitral valve on the side corresponding to the heart's left ventricle. The pressure is increased until fluid flows through the valve, i.e. until it fails. A specific dissection technique has been developed to produce a specimen with two annular rings, mitral annulus and papillary muscle annulus. Since the valve is maintained intact, with its leaflets attached to papillary muscles by the chordae tendineae, this method allows the effects of ruptured chordae and their surgical repair or replacement to be assessed in vitro. The chamber that holds the valve supports both the mitral annulus and papillary muscle annulus of the specimen. The mitral annulus is sutured onto rubber sheeting held in the chamber. The papillary muscle annulus is held in place by a Perspex support. The main part of the apparatus consists of a water pump connected through flexible tubing to the chamber that holds the valve in place. The pressure at failure is measured using a pressure transducer. Preliminary experiments demonstrate that anterior leaflet marginal chordae, but not strut chordae, are vital to valve function. Posterior leaflet chordae have been found to be important for valve competence.

Aortic Valve↗

Mechanical properties of calcium sulphate/hydroxyapatite cement.

Setting times, volume after setting, injectability and hardness (at 37 degrees C in contact with Ringer's solution) were determined for cements made of mixtures of calcium sulphate hemihydrate (CS) and hydroxyapatite (HA) with a range of compositions. The purpose of these experiments was to determine the behaviour of a mixture that could be used as an injectable cement for orthopaedic applications, including spinal fusion. A suitable mixture consisted of 60% CS and 40% HA by mass; a slurry was made by mixing solid (36 g) with water (15 cm(3)). The slurry had initial and final setting times of 5.7+/-1.3 min and 19.6+/-0.7 min (mean +/- standard deviation), respectively. The hardness of the cement did not systematically increase or decrease in the 72 h following the final setting time. The volume of the cement was 99.8+/-0.4% of the volume of the initial slurry, i.e. there was negligible shrinkage on setting. It was able to withstand a pressure of 7.3+/-1.2 MPa, applied by a hemispherical indenter before the onset of permanent damage, indicating adequate strength for spinal fusion.

Biocompatible Materials↗

Influence of fibril taper on the function of collagen to reinforce extracellular matrix.

Collagen fibrils provide tensile reinforcement for extracellular matrix. In at least some tissues, the fibrils have a paraboloidal taper at their ends. The purpose of this paper is to determine the implications of this taper for the function of collagen fibrils. When a tissue is subjected to low mechanical forces, stress will be transferred to the fibrils elastically. This process was modelled using finite element analysis because there is no analytical theory for elastic stress transfer to a non-cylindrical fibril. When the tissue is subjected to higher mechanical forces, stress will be transferred plastically. This process was modelled analytically. For both elastic and plastic stress transfer, a paraboloidal taper leads to a more uniform distribution of axial tensile stress along the fibril than would be generated if it were cylindrical. The tapered fibril requires half the volume of collagen than a cylindrical fibril of the same length and the stress is shared more evenly along its length. It is also less likely to fracture than a cylindrical fibril of the same length in a tissue subjected to the same mechanical force.

Biomechanical Phenomena↗

Thermal stability and structure of cancellous bone mineral from the femoral head of patients with osteoarthritis or osteoporosis.

BACKGROUND: Cancellous bone from patients with osteoarthritis (OA) has been reported to be undermineralised and that from patients with osteoporosis (OP) is more liable to fracture. Changes in the mineral component might be implicated in these processes. OBJECTIVES: To investigate the thermal stability and the mineral structure of cancellous bone from femoral heads of patients with either OA or OP. METHODS: Powdered bone was prepared from femoral heads of patients with either OA or OP and a control group. Composition and thermal stability were determined using a thermogravimetric analyser coupled to a mass spectrometer. Unit cell dimensions and the crystallite size of the mineral were measured using x ray diffraction. RESULTS: Thermal stability of the bone matrix, or of the mineral phase alone, was little altered by disease, though OA bone contained less mineral than OP or control bone. In all three groups, x ray diffraction showed that the mineral unit cell dimensions and crystallite sizes were the same. The mean carbonate content in the mineral from all three groups was between 7.2 and 7.6% and is suggested to be located in both the A site (that is, substituting for hydroxyl groups), and the B site (that is, substituting for phosphate groups). CONCLUSIONS: These results confirm that there is a lower mass fraction of mineral in OA bone, and indicate that the nature of the mineral is not a factor in either disease process.

Aged↗

Wire tension in the Ilizarov system: accuracy of the wire-tensioning device.

The Ilizarov fixator consists of tensioned wires that attach bone segments to a modular frame. The aim of this study was to establish the accuracy and precision of the wire-tensioning device supplied with the Ilizarov external fixation system. The device was used to tension a wire in direct opposition to a calibrated load cell. Five subjects tested three devices, at each of their four tension settings, in two separate sessions. Subjects could not see the true tension during the test. There were significant differences between the results for different subjects (p < 0.01) and instruments (p < 0.01) but not for different tension settings or between the two sessions. Overall mean measured tensions were 4.9 per cent (standard deviation, 4.4 per cent) below intended values. Tensions obtained at the maximum edge (completely occluded) on the scale markings were significantly (p < 0.001) closer to the nominal values (mean discrepancy, 3.6 per cent) than those at the minimum edge (mean discrepancy, 17.6 per cent). Several factors influence wire tension. Tensioning devices are not identical and the results obtained with them depend on the user. If the scale markings are completely occluded, the discrepancy between intended and actual tensions of around 5 per cent is likely to be adequate for clinical practice since surgeons do not select the most suitable tension following quantitative data assessment, but rather it is a judgement based on surgical experience and consideration for the patient weight and expected level of activity.

Bone Wires↗

Effect of the proportion of organic material in bone on thermal decomposition of bone mineral: an investigation of a variety of bones from different species using thermogravimetric analysis coupled to mass spectrometry, high-temperature X-ray diffraction, and Fourier transform infrared spectroscopy.

Thermogravimetric analysis linked to mass spectrometry (TGA-MS) shows changes in mass and identifies gases evolved when a material is heated. Heating to 600 degrees C enabled samples of bone to be classified as having a high (cod clythrum, deer antler, and whale periotic fin bone) or a low (porpoise ear bone, whale tympanic bulla, and whale ear bone) proportion of organic material. At higher temperatures, the mineral phase of the bone decomposed. High temperature X-ray diffraction (HTXRD) showed that the main solids produced by decomposition of mineral (in air or argon at 800 degrees C to 1000 degrees C) were beta-tricalcium phosphate (TCP) and hydroxyapatite (HAP), in deer antler, and CaO and HAP, in whale tympanic bulla. In carbon dioxide, the decomposition was retarded, indicating that the changes observed in air and argon were a result of the loss of carbonate ions from the mineral. Fourier transform infrared (FTIR) spectroscopy of bones heated to different temperatures, showed that loss of carbon dioxide (as a result of decomposition of carbonate ions) was accompanied by the appearance of hydroxide ions. These results can be explained if the structure of bone mineral is represented by [Formula: see text] where V(Ca) and V(OH) correspond to vacancies on the calcium and hydroxide sites, respectively, and 2-x-y = 0.4. This general formula is consistent in describing both mature bone mineral (i.e., whale bone), with a high Ca/P molar ratio, lower HPO4(2-) content, and higher CO3(2-) content, and immature bone mineral (i.e., deer antler), with a low Ca/P ratio, higher HPO4(2-), and lower CO3(2-) content.

Animals↗

Short communication: fused deposition models from CT scans.

Fused deposition modelling (FDM) is a new method for rapid prototyping, a technique that produces models of objects from computer files. The most commonly used rapid prototyping technique for medical applications is stereolithography, but FDM has several potential advantages. This paper is concerned with the accuracy of an FDM model of a sheep lumbar vertebra using data from a CT scan. The model and the original vertebra were compared by making measurements with vernier callipers and by laser scanning. Visually, the model reproduced the features of the original object; this conclusion was supported by a comparison of the laser scans. Discrepancies in measurements were comparable with those of models produced using other rapid prototyping techniques, demonstrating that FDM is a viable method for making models for clinical use.

Animals↗

Thermal analysis of poly(2-hydroxyethyl methacrylate) (pHEMA) hydrogels.

The influence of water on the physical properties of a hydrogel is important for understanding natural tissues and in designing synthetic materials to replace them. In this study, poly (2-hydroxyethyl methacrylate) (pHEMA) was used as a model system to understand how water interacts with the polymer of a hydrogel. Thermal analysis methods (thermogravimetric analysis coupled to mass spectrometry and differential scanning calorimetry) were used to determine: (i) the total water content of pHEMA gels; (ii) how this water was lost during heating; (iii) the relationship between water content of the gel and its glass transition temperature; and (iv) the behavior of the water in the gel on cooling. Previous researchers have invoked various models to describe the organization of water in a hydrogel. In this study, the simplest model which could explain all of the results from the different thermal analysis techniques was one which consisted of three classes of water: (i) hydration water in close proximity to the polymer; (ii) interstitial water in regions or cavities surrounded by polymer chains; and (iii) bulk water.

Journal Article↗

Rheological properties of poly(2-hydroxyethyl methacrylate) (pHEMA) as a function of water content and deformation frequency.

Poly(2-hydroxyethyl methacrylate) (pHEMA) hydrogels have been used, or suggested for use, in a wide range of biomedical applications. In many of these applications, the mechanical properties of the gel are important for its proper functioning. These properties are influenced by a number of factors, including water content. In this study the storage and loss shear moduli were measured as a function of frequency for gels with water contents ranging from 22% to 48% at a temperature of 37 degrees C. At low frequencies and high water contents, deformation frequency had little effect. However, at higher frequencies and lower water contents, both moduli increased markedly with increasing frequency. This can be explained by the gels approaching a glass transition. The curves describing the behavior of each gel were combined to form a master curve, using a method analogous to the time-temperature superposition principle. This master curve can be used to predict the shear moduli for gels with a wide range of water contents and loading frequencies. For example, for a gel with a water content of 47.8% (as a percentage of the mass of gel), the curve provides shear moduli values over a frequency range of 10(-2)-10(4) Hz.

Journal Article↗

Polarization artefacts of an FTIR microscope and the consequences for intensity measurements on anisotropic materials.

The infrared beam on both the main Nicolet Nexus bench and the attached Spectra-Tech Continuum microscope has been shown to be partially polarized. The degree of polarization is approximately 30%. Although the state of polarization of the infrared beam is of no consequence when measuring the spectra of isotropic materials (gases, liquids), there is a potential problem when considering the spectra of anisotropic materials. Single band intensities are particularly prone to error as small changes in sample thickness or orientation directly affect the intensity. Thickness effects can be overcome by measuring intensity ratios. However, because of the partially polarized nature of the infrared beam, even intensity ratios, illustrated here by the ratio amide I/II of collagen fibres, vary with sample orientation. If overlooked, this effect can be problematic when measuring infrared spectra with an FTIR microscope from samples that are anisotropic or contain anisotropic domains, even though they may appear isotropic on a macroscopic scale. Because dichroic ratios remain unaffected, the intensity ratio from two bands with different transition moments may be used to give a strong indication of the orientation of the sample. This work is illustrated by reference to the FTIR spectra of orientated polyethylene, collagen tape and human trabecular bone.

Amides↗

The effect of clamping a tensioned wire: implications for the Ilizarov external fixation system.

This study demonstrates that clamping a tensioned wire can cause a reduction in wire tension. Tension (about 1275 N) was applied to a wire that was subsequently clamped, using cannulated bolts, to the steel half-ring of an Ilizarov external fixator. The tension in the wire was monitored before, during and after clamping. The apparatus was disassembled and the deformations in the wire caused by the clamps were measured. This experiment was repeated 15 times. When the wire was clamped to the frame, the wire tension was reduced by 22 +/- 7 per cent (mean +/- standard deviation, SD). The drop in wire tension was linearly correlated (r = 0.96; p < 0.001) with the deformation caused by the bolts. A finite element (FE) model of the wire was also constructed. The model was pre-stressed (tensioned), and the clamping effect replicated. This analysis showed that clamping the wire could be considered to squeeze the wire outwards (like toothpaste from a tube) and so reduce its tension during fixator assembly. To assess the magnitude of this effect in the clinical situation, the FE model analysis was repeated to replicate clamping a 1.8-mm-diameter wire to a 180-mm-diameter steel Ilizarov ring component. The analysis showed that for these conditions the tension reduced by 8-29 per cent. The results of this study highlight a general engineering problem: how can a tensioned wire be secured to a structure without an appreciable loss of tension? If the performance of the structure depends on the wire tension, this performance will change when the wire is secured.

Bone Wires↗

Fatigue strength of a wire passing through a cannulated screw: implications for closure of the sternum following cardiac surgery.

It has been proposed that the incidence of sternal dehiscence can be decreased by passing the wires used for sternotomy closure through cannulated screws. However, there is a potential risk of fatigue failure as a result of the wire moving against the screw, e.g. during coughing and sneezing. The system of cannulated screws and wire was subjected to static tensile testing to failure. Five tests were performed and failure occurred at 388 +/- 34 N (mean +/- SD). Ten cyclic tests were then performed. Sinusoidal loading was applied at 10 Hz with peak forces in the range 10-90 per cent of the static failure force, at a constant load ratio R = 10. The test with the lowest peak force reached run-out at 6 x 10(6) cycles. The others failed by the ends of the wire closures becoming untwisted (one test), the wire fracturing at the twist (three tests) or the wire fracturing at the screw (five tests). However, calculations based on these results suggest that fatigue failure is unlikely to occur as a result of regular breathing or continuous coughing or sneezing.

Bone Screws↗

Yielding of the clamped-wire system in the Ilizarov external fixator.

This study demonstrates that the clamped-wire system used to suspend bones within an Ilizarov external fixator yields when the perpendicular load exceeds 50 N per wire. Cyclic loading was applied to tensioned wires clamped within an Ilizarov ring component, with steadily increasing load amplitude. Wires were tested at four initial tension settings. The amount of energy lost within the clamped-wire system per load cycle was calculated for every test. The results showed that there was a consistent trend to increasing non-recoverable energy loss per load cycle when peak loads exceed 50 N for all initial tension settings. A finite element (FE) model replicating the experimental conditions was performed to investigate the levels of stress within the loaded wires. The FE model analyses showed that high stresses were generated in the wires close to the clamping sites, and that the stress levels could reasonably be expected to exceed the material yield stress when loaded to about 55 N, for all initial tension settings. The results show that material yield, accompanied by some wire slippage through the clamps, is responsible for system yield, in agreement with previous studies. Although the initial wire tension has an appreciable effect on the wire stiffness, it did not affect the elastic load range of the clamped-wire system. To prevent yield of the clamped-wire system in practice, the fixator should be assembled with sufficient wires to ensure that the load transmitted to each wire by the patient does not exceed 50 N.

Bone Wires↗

Sheep lumbar intervertebral discs as models for human discs.

OBJECTIVE: To determine the water content, collagen content and collagen orientation angle in different regions of sheep lumbar discs. DESIGN: A laboratory study of sheep discs obtained from an abattoir. METHODS: A total of 21 sheep lumbar discs were obtained from three lumbar spines. Water content was determined by oven drying (60 degrees C) to constant mass. Collagen content was determined by hydroxyproline analysis. Fibre orientation angles were determined by X-ray diffraction. RESULTS: Water content increased from 74% of total tissue mass in the outer annulus, to 82% in the inner annulus, to 86% in the nucleus. Collagen content decreased from 30% of total tissue mass in the outer region to 20% in the inner region of the anterior and lateral annulus; it was 16% in the posterior annulus. The orientation angle of the collagen fibres decreased from 59 degrees in the outer region to 56 degrees in the inner region of the anterior and lateral annulus; it was 51 degrees in the posterior annulus. CONCLUSIONS: Sheep lumbar intervertebral discs provide a reasonable model for human lumbar intervertebral discs. RELEVANCE: Sheep lumbar discs have been used to investigate the effects of removing and replacing the nucleus. These studies indicate that removal of nucleus may lead to further disc degeneration and indicate the material properties required for an implant material. The relevance of these previous studies is increased if human and sheep lumbar discs have a similar composition and structure.

Animals↗

Finite element analysis of stress around a sternum screw used to prevent sternal dehiscence after heart surgery.

The sternum screw has been proposed as a means of preventing sternal dehiscence, following heart surgery, by increasing the contact area between the wire used to close the median sternotomy and the surrounding bone; as a result, the contact stress is reduced. A finite element model was constructed of a cylindrical wire or screw passing through a block of sternum which consisted of cancellous bone sandwiched within a cortical shell. The thickness of the cortical shell and the material properties of bone were varied between reasonable values. The stress distribution in the sternum was calculated for each model when the wire was subjected to a tension (250 N) which would be required for six wires to withstand a strong cough (40 kPa). Results were validated by comparison with a simple analytical model in which the bone and wire were considered incompressible. They show that the screw reduces the contact stress to almost one-seventh of its value when wire is used alone. Contact stresses are especially high if the cortical shell is thin. The high stress in the bone around a screw falls off within a few millimetres. As a result, no problems are anticipated in placing six screws in each half-sternum so that the sternotomy may be closed with the usual six wires.

Bone Screws↗