Publications and source records attributed to D W Litzenberg.

5 recordsLinked to original sources

An apparatus for applying strong longitudinal magnetic fields to clinical photon and electron beams.

Monte Carlo studies have recently renewed interest in the use of the effect of strong transverse and longitudinal magnetic fields to manipulate the dose characteristics of clinical photon and electron beams. A 3.5 T superconducting solenoidal magnet was used to evaluate the effect of a longitudinal field on both photon and electron beams. This note describes the apparatus and demonstrates some of the effects on the beam trajectory and dose distributions for measurements in a homogeneous phantom. The effects were studied using film in air and in phantoms which fit in the magnet bore. The magnetic field focused and collimated the electron beams. The converging, non-uniform field confined the beam and caused it to converge with increasing depth in the phantom. Due to the field's collecting and focusing effect, the beam flux density increased, leading to increased dose deposition near the magnetic axis, especially near the surface of the phantom. This study illustrates some benefits and challenges associated with the use of non-uniform longitudinal magnetic fields in conjunction with clinical electron and photon beams.

Electrons↗

A comparison of ventilatory prostate movement in four treatment positions.

PURPOSE: To ensure target coverage during radiotherapy, all sources of geometric uncertainty in target position must be considered. Movement of the prostate due to breathing has not traditionally been considered in prostate radiotherapy. The purpose of this study is to report the influence of patient orientation and immobilization on prostate movement due to breathing. METHODS AND MATERIALS: Four patients had radiopaque markers implanted in the prostate. Fluoroscopy was performed in four different positions: prone in alpha cradle, prone with an aquaplast mold, supine on a flat table, and supine with a false table under the buttocks. Fluoroscopic movies were videotaped and digitized. Frames were analyzed using 2D-alignment software to determine the extent of movement of the prostate markers and the skeleton for each position during normal and deep breathing. RESULTS: During normal breathing, maximal movement of the prostate markers was seen in the prone position (cranial-caudal [CC] range: 0.9-5.1 mm; anterior-posterior [AP] range: up to 3.5 mm). In the supine position, prostate movement during normal breathing was less than 1 mm in all directions. Deep breathing resulted in CC movements of 3.8-10.5 mm in the prone position (with and without an aquaplast mold). This range was reduced to 2.0-7.3 mm in the supine position and 0.5-2.1 mm with the use of the false table top. Deep breathing resulted in AP skeletal movements of 2.7-13.1 mm in the prone position, whereas AP skeletal movements in the supine position were negligible. CONCLUSION: Ventilatory movement of the prostate is substantial in the prone position and is reduced in the supine position. The potential for breathing to influence prostate movement, and thus the dose delivered to the prostate and normal tissues, should be considered when positioning and planning patients for conformal irradiation.

Adenocarcinoma↗

On-line monitoring of radiotherapy beams: experimental results with proton beams.

Proton radiotherapy is a powerful tool in the local control of cancer. The advantages of proton radiotherapy over gamma-ray therapy arise from the phenomenon known as the Bragg peak. This phenomenon enables large doses to be delivered to well-defined volumes while sparing surrounding healthy tissue. To fully realize the potential of this technique the location of the high-dose volume must be controlled very accurately. An imaging system was designed and tested to monitor the positron-emitting activity created by the beam as a means of verifying the beam's range, monitoring dose, and determining tissue composition. The prototype imaging system consists of 12 pairs of cylindrical BGO detectors shielded in lead. Each crystal was 1.9 cm in diameter, 5.0 cm long, and separated by 0.5 cm from other detectors in the row. These are arranged in two rows, 60 cm apart, with the proton beam and tissue phantoms half-way between and parallel to the detector rows. Experiments were conducted with 150 MeV continuous and macro-pulsed proton beams which had beam currents ranging from 0.14 nA to 1.75 nA. The production and decay of short-lived isotopes, 15O and 14O, was studied using 1 min irradiations with a continuous beam. These isotopes provide a significant signal on short time scales, making on-line imaging possible. Macro-pulsed beams, having a period of 10 s, were used to study on-line imaging and the production and decay of long-lived isotopes, 13N, 11C, and 18F. Decay data were acquired and on-line images were obtained between beam pulses and indicate that range verification is possible, for a 150 MeV beam, after one beam pulse, to within the 1.2 cm resolution limit of the imaging system. The dose delivered to the patient may also be monitored by observing the increase in the number of coincidence events detected between successive beam pulses. Over 80% of the initial positron-emitting activity is from 15O while the remainder is primarily 11C, 13N, 14O with traces of 18F, and 10C. Radioisotopic imaging may also be performed along the beam path by fitting decay data collected after the treatment is complete. Using this technique, it is shown that variations in elemental composition in inhomogenous treatment volumes may be identified and used to locate anatomic landmarks. Radioisotopic imaging also reveals that 14O is created well beyond the Bragg peak, apparently by secondary neutrons.

Biophysical Phenomena↗

A mathematical model for correcting patient setup errors using a tilt and roll device.

An algorithm is presented for determining how to adjust the actuators of a tilt and roll table. The algorithm is based on a geometrical model of the table, which was designed with six degrees of freedom. This design and algorithm allows complete translational and rotational corrections to be applied to the target volume position on a daily basis.

Algorithms↗

A tilt and roll device for automated correction of rotational setup errors.

A tilt and roll device has been developed to add two additional degrees of freedom to an existing treatment table. This device allows computer-controlled rotational motion about the inferior-superior and left-right patient axes. The tilt and roll device comprises three supports between the tabletop and base. An automotive type universal joint welded to the end of a steel pipe supports the center of the table. Two computer-controlled linear electric actuators utilizing high accuracy stepping motors support the foot of table and control the tilt and roll of the tabletop. The current system meets or exceeds all pre-design specifications for precision, weight capacity, rigidity, and range of motion.

Biophysical Phenomena↗