PubMed Health⌕ Search

Biomedical subjects

D W Warner

Publications and source records attributed to D W Warner.

4 recordsLinked to original sources

The correlation between serum selenium and blood selenium in cattle.

The selenium (Se) concentration of paired blood and serum samples from cattle was determined by 2 methods: 1) atomic absorption spectroscopy using hydride generation (HG-AAS), and 2) inductively coupled argon plasma emission spectroscopy using hydride generation (ICP). Samples from 327 cattle were analyzed by HG-AAS, and samples from 344 cattle were analyzed by ICP. The data were examined by linear regression analysis, and the technique of inverse prediction was utilized to determine prediction intervals for estimating blood Se concentration from known serum Se concentration. The correlation coefficients, by simple linear regression of serum Se on blood Se, were 0.79 (r2 = 0.62) and 0.88 (r2 = 0.77) for the HG-AAS data and the ICP data, respectively. For the HG-AAS data, the inverse prediction formula for estimating blood Se when serum Se is known, at the 95% prediction interval, was [formula; see text]. For the ICP data, the inverse prediction formula for estimating blood Se when serum Se is known, at the 95% prediction interval, was [formula; see text]. The prediction intervals were quite wide, and the accuracy of estimating blood Se from a known serum Se was not useful for diagnostic purposes. The use of serum Se concentration to assess nutritional status of cattle with respect to Se does not appear to be appropriate.

Animals↗

Unstable injectable selenium treatments that may be toxic to cattle.

High or toxic tissue levels of selenium resulted from administration of the aqueous layer of an unstable injectable oil emulsion of selenium and vitamins A and D. Since selenium partitioned from hydrophobic to aqueous media in the poorly mixed product, the aqueous portions constituted a significant threat to health.

Animals↗

Analysis of interlaboratory performance in the determination of total selenium in water.

This study explored the performance of experienced laboratories in the analysis for total selenium in water by a variety of analytical methods. The goal of the study was to examine intra- and interlaboratory variability. Replicates (n = 7) of 7 sample types that included a reference material of known Se concentration, natural waters, and treated wastewaters were submitted to 7 laboratories with prequalified Se analytical experience. Results of the study indicated wide ranges in minimum and maximum results, distinct differences in laboratory precision, and routine reporting of numerical results below statistical limits of quantitation. Hydride generation as a sample introduction technique demonstrated superior performance. In general, the study supports a caution advisory about using low-level Se data, especially results lower than about 10 micrograms Se/L, without quantitating the statistical uncertainty of the data. Because this study used data from samples that were submitted in bulk to participating laboratories prequalified for Se analytical expertise and experience, it can be considered a best-case demonstration of performance.

Chemistry Techniques, Analytical↗