PubMed Health⌕ Search

Biomedical subjects

D Wörz

Publications and source records attributed to D Wörz.

2 recordsLinked to original sources

[Clinical results with A new retrograde femoral nail with a radiographical-free proximal locking device. A prospective study with 50 fractures].

INTRODUCTION: Conventional retrograde nailing of the femur causes two important disadvantages: the proximal locking of the nail is difficult because of the anatomic conditions and a chondral defect was left into the knee. MATERIAL AND METHODS: After the retrograde implantation the new nail was lead through the greater trochanter. An additional proximal aiming device for proximal interlocking can be fixed. The entrance portal will be sealed by an osteochondral cylinder. 50 cases of femur fractures were selected for the prospective study. We recorded all intraoperative complications and technical difficulties. The cases were followed up for 52 weeks, both clinical and radiology examinations were performed. RESULTS: The mean follow up was 15.5+/-5 months. All fractures were healed. Knee movement was 125+/-14 degrees. The Leung Score was 84+/-12.6 points; HSS Score was 90+/-9 points. In two cases wound infections were developed. Mal-union was observed in three cases, in two cases nail brake down. CONCLUSIONS: The new retrograde interlocking nail could be used to manage femur fractures successfully. Two aiming devices enable a easy interlocking. Replacement of the osteochondral cylinder into the entry portal reduces cartilage damage.

Adolescent↗

Multiple suicidal gunshots to the head.

We report two cases of suicide by multiple gunshots to the head. The first victim (of two shots) fired the first shot, which was observed, into his mouth, leading to damage to the left optic nerve and frontal lobe. The man still was able to drive his car home, where he shot himself in his right temple. He died 2 days later. The second victim (of three shots) was a 58-year-old man who was found dead on his bed. Reconstruction of the case disclosed that the first shot had passed through his tongue and slightly damaged the second cervical vertebral body. He then shot himself in his right temple, leading to damage of the temporal lobe. Finally, he shot himself in his left temple, resulting in destruction of the pons. In the first case, an amateurishly modified 8-mm blank revolver firing 6.35-mm- (.25)-caliber ammunition was used; in the second case, a rifle firing 5.6-mm (.22)-caliber ammunition with a reduced charge was used. In both cases, low-energy transfer to brain tissue by the initial bullets was due to low bullet energy or due to the bullets' missing the brain or vital centers.

Adult↗