PubMed Health⌕ Search

Biomedical subjects

D Wallin

Publications and source records attributed to D Wallin.

6 recordsLinked to original sources

Microwave detection at 110 Ghz by nanowires with broken symmetry.

By using arrays of nanowires with intentionally broken symmetry, we were able to detect microwaves up to 110 GHz at room temperature. This is, to the best of our knowledge, the highest speed that has been demonstrated in different types of novel electronic nanostructures to date. Our experiments showed a rather stable detection sensitivity over a broad frequency range from 100 MHz to 110 GHz. The novel working principle enabled the nanowires to detect microwaves efficiently without a dc bias. In principle, the need for only one high-resolution lithography step and the planar architecture allow an arbitrary number of nanowires to be made by folding a linear array as many times as required over a large area, for example, a whole wafer. Our experiment on 18 parallel nanowires showed a sensitivity of approximately 75 mV dc output/mW of nominal input power of the 110 GHz signal, even though only about 0.4% of the rf power was effectively applied to the structure because of an impedance mismatch. Because this array of nanowires operates simultaneously, low detection noise was achieved, allowing us to detect -25 dBm 110 GHz microwaves at zero bias with a standard setup.

Electric Impedance↗

A comparison of routine and rapid microwave tissue processing in a surgical pathology laboratory. Quality of histologic sections and advantages of microwave processing.

Rapid processing of histopathologic material is becoming increasingly desirable to fulfill the needs of clinicians treating acutely ill patients. Traditional techniques for rapid processing of paraffin-embedded tissues require 4 to 5 hours, delaying treatment for some critically ill patients and requiring additional shifts of technologists in the laboratory. Microwave processing further shortens this time, allowing even more rapid histopathologic diagnosis. Few data exist comparing quality of microwave-processed tissue with that processed by more traditional techniques. We randomly selected 158 paired specimens from 111 patients. One member of the pair was processed routinely overnight, while the other was processed by the rapid microwave technique. The slides then were compared for quality of histologic preparation in a blinded fashion by 2 pathologists. Eight routinely processed specimens were judged as suboptimal, while 6 microwave-processed specimens were judged as suboptimal and 1 was considered unsatisfactory for evaluation. In the remaining cases, the material obtained by the 2 techniques was considered of identical quality. Microwave processing considerably shortens the preparation time for permanent histologic sections without a demonstrable decrease in section quality or "readability."

Female↗

A comparison of intravenous nicardipine and sodium nitroprusside in the immediate treatment of severe hypertension.

The primary objective of this study was to compare the antihypertensive efficacy and safety of intravenously administered nicardipine with that of intravenous nitroprusside (SNP) in patients with severe hypertension. The study was conducted in 121 patients with severe hypertension (diastolic blood pressure [BP] > 120 mm Hg, or systolic BP > 200 mm Hg). Patients were randomized to receive intravenous nicardipine or SNP. Drugs were administered according to a predetermined dosing schedule for a 10 to 12 h period. Sixty-one patients were randomized to intravenous nicardipine and 60 to SNP. Pretreatment BP values for the nicardipine and SNP groups were 217/128 mm Hg and 219/128 mm Hg, respectively. Therapeutic response (diastolic BP < 100 mm Hg, or a decrease of > 15 mm Hg; systolic BP < 180 mm Hg, or a decrease of > 20 mm Hg) was achieved in 98% (60/61) of patients treated with nicardipine and 93% (56/60) of patients treated with SNP. The mean decreases in systolic and diastolic BP were 61 mm Hg and 40 mm Hg after 4 h of nicardipine, and 59 mm Hg and 38 mm Hg after 4 h of SNP. The mean increases in heart rate also were similar in both groups (nicardipine, 12 beats/min; SNP 10 beats/min). The mean numbers of dose adjustments per hour required to maintain the BP reductions were lower (P < .01) in the nicardipine-treated patients (0.5 +/- 0.1 times per hour) than in the SNP-treated patients (1.5 +/- 0.2 times per hour).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

The effects of enoximone on renal function in patients with congestive heart failure.

Enoximone is an investigational cardiotonic agent with positive inotropic and vasodilatory properties. In this protocol the effects of enoximone on parameters of renal function in patients (n = 14) with New York Heart Association class II or III congestive heart failure were determined after intravenous (IV) treatment (2 mg/kg) and after chronic oral administration (150 mg t.i.d.), either alone or with added furosemide (40 mg b.i.d.). Glomerular filtration rate (GFR), effective renal plasma flow (ERPF), filtration fraction, mean arterial pressure (MAP), renal blood flow (RBF), and renal vascular resistance (RVR) were determined each time. Plasma volume (PV) was determined at baseline and after oral enoximone and after oral enoximone plus furosemide. Significant reductions in GFR (18%) and ERPF (20%) were observed after IV treatment but not after oral treatment with or without furosemide. MAP also was lowered significantly by 14% after IV administration but not after oral treatments. PV after oral enoximone plus furosemide was reduced significantly (31%) compared with baseline. These results demonstrate that enoximone produces acute reductions in GFR and ERPF when given intravenously but has no effect on parameters of renal function when given orally, either alone or with furosemide.

Adult↗

Improvement of muscle flexibility. A comparison between two techniques.

Forty-seven male subjects were randomly assigned to 4 different groups. Three groups of 10 subjects trained three times a week with a modified contract-relax (CR) method for improving muscle flexibility. Seventeen subjects trained during the same time with a traditional ballistic stretch (BS) method. After 30 days (14 training sessions) the latter group switched over to the CR method. The results showed that the CR method was significantly better than the BS method for improving muscle flexibility in the four different, bilateral muscle groups studied. After the initial 30 days the three groups of 10 subjects trained one, three, and five times a week, respectively, for another 30 days. The results showed that once a week was enough to maintain improved flexibility, while three and five times a week increased it further. The former BS group improved muscle flexibility between the 30th and 60th day, as expected from the results of the initial 30 days with the three CR groups, when training with the CR method three times a week.

Adult↗