[Manipulator assisted endoscope guidance in functional endoscopic sinus surgery: proof of concept].

BACKGROUND: Functional endoscopic sinus surgery (FESS) is characterized by single-handed preparation and guidance of the endoscope by the nondominant hand. This results in an additional extension of operation time by up to 15% and ergonomic deficits. The aim of this study is the conception of an automated assistance system for FESS in view of the following questions: (1) Which degree of surgical automation is suitable for FESS? (2) Which design is suitable? (3) What are the properties of the technical system (planning, time, accuracy, precision) of the selected system? (4) Does the system offer potential for a clinical application? METHODS: In all 49 FESS were analyzed for surgical workflows. Measurement of the maximum forces within FESS was performed with 40 trials on an anatomical model. Three different mechanical systems were used in ten FESS and evaluated using the ICCAS Human-Machine Evaluation Scale. For realization of automated endoscope guidance an engine-driven and -braked manipulator (PA10-6c, Mitsubishi, Japan) was used. The technical parameters determined were expenditure of time for the preoperative planning of workspace, surgical accuracy and precision of the intraoperative endoscope positioning, maximal forces, and time. RESULTS: Concept-conditioned instrument changes amount to an average of 41.1 and 18.9% (5.21 min) time requirement for each FESS side. Maximum forces on the mucous membrane during a conventional FESS were measured at 9.8 N (5.9-9.8). Usability of the mechanical endoscope holder was estimated in 18 of 20 cases to be inferior to the standard procedure. The time needed for segmenting the intranasal workspace was 15.2 min (10.0-23.0). The maximum deviation of the automatically driven endoscope from a planned position amounted to 0.85 mm (manually 4.64 mm). The maximum force was measured with 1.1 N in the z direction (manually 9.8 N). Automated guidance of the endoscope to an intranasal position needed 7.25 s (6.4-7.9); manually 12.64 s (5.9-43.0). CONCLUSION: Guidance of the endoscope for FESS by an automated motor-driven system is possible. The conception which is based on workflow analysis favors a system with automatic definition of the workspace and a manual movement of the endoscope. The examined system offers a potential for clinical application. Definition of the automation level and development of a man-machine interface is more important than selection or reconstruction of a special manipulator for endoscope guidance in FESS from a surgical point of view.

Endoscopes↗

[Three-dimensional visualization of CT of the neck for surgical planning].

BACKGROUND: Surgical planning in ENT profits from computer assisted preoperative visualization and planning. The informative capability is to be improved by three-dimensional illustrating of the preoperative available data. The possibility of a 3-D-visualization of lymph nodes stands in the center of the interest. METHODS: 16 CT data sets with a tumor-classification of T1N1 or higher were included. Altogether 720 pseudo-3-D-illustrations were provided with an average of 9.3 objects. Current algorithms were used for the segmentation and visualization and the results were divided in three classes. RESULTS: The average time requirement for visualization and segmenting amounted to 122 minutes, the minimum value is at 61 minutes per data set. Automatic segmenting succeeded only with structures with clear grey tone differences to the environment. In all other cases an additional manual interaction had to take place. CONCLUSIONS: 3-D-Visualising of CT of the neck represents a new quality in preoperative planning. A clear trend at increasing detail loyalty and information efficiency showed up in the groups of B and C. It is possible to make from these pictures a quantitative statement on surgery relevant infiltration. Likewise conceivable are the postoperative quality control or planning and process control of a postoperative radio-chemotherapy. The automatic algorithms can be estimated as reliable. Application is still far from a clinically efficient use. With the rising efficiency of the computing systems, the improved software and the imaging systems the problems mentioned are, however, solvable.

Algorithms↗

[Accuracy and precision in the evaluation of computer assisted surgical systems. A definition].

Accuracy represents the outstanding criterion for navigation systems. Surgeons have noticed a great discrepancy between the values from the literature and system specifications on one hand, and intraoperative accuracy on the other. A unitary understanding for the term accuracy does not exist in clinical practice. Furthermore, an incorrect equality for the terms precision and accuracy can be found in the literature. On top of this, clinical accuracy differs from mechanical (technical) accuracy. From a clinical point of view, we had to deal with remarkably many different terms all describing accuracy. This study has the goals of: 1. Defining "accuracy" and related terms, 2. Differentiating between "precision" and "accuracy", 3. Deriving the term "surgical accuracy", 4. Recommending use of the the term "surgical accuracy" for a navigation system. To a great extent, definitions were applied from the International Standardisation Organisation-ISO and the norm from the Deutsches Institut für Normung e.V.-DIN (the German Institute for Standardization). For defining surgical accuracy, the terms reference value, expectation, accuracy and precision are of major interest. Surgical accuracy should indicate the maximum values for the deviation between test results and the reference value (true value) A(max), and additionally indicate precision P(surg). As a basis for measurements, a standardized technical model was used. Coordinates of the model were acquired by CT. To determine statistically and reality relevant results for head surgery, 50 measurements with an accuracy of 50, 75, 100 and 150 mm from the centre of the registration geometry are adequate. In the future, we recommend labeling the system's overall performance with the following specifications: maximum accuracy deviation A(max), precision P and information on the measurement method. This could be displayed on a seal of quality.

Equipment Failure Analysis↗

[Workflow analysis to assess the efficiency of intraoperative technology using the example of functional endoscopic sinus surgery].

Evaluation of the efficiency of surgical technology systems has to date been largely subjective. The aim of this study was to develop an ontology for surgical procedures usable workflow structures, and the evaluation of surgical workflow analysis using the example of functional endoscopic sinus surgery (FESS). A total of 38 procedures (20 patients) were included. Surgery was carried out by seven different surgeons with different degrees of training. Description of the surgical procedures and resources is based on the standard EN1828/2001 (Structure for Classification and Coding Systems for Surgical Procedures). In addition the requirements of the Workflow Reference Models (document no. Tc00-1003), Workflow Management Coalition (WfMC) were integrated. The workflow recorded the position, frequency of change of position, use time, cleaning time and concept based instrument changes. A total of 293 items were used to define FESS. A total of 1,029 different endoscopic positions were documented. These could be combined into five major endoscopic positions. The frequency of position changes was 27.1 per side, the period spent in an endoscopic position is about 1.31 min. Time for the concept-caused instrument changing was 6.44 min per side. This study demonstrates the need for assistance in guiding the endoscope in FESS. Using the workflow-data, the concept of an assistant system is possible. We offer a basis for discussion of the development of an ontology, recording and analysing surgical workflows and their practical application.

Biotechnology↗

Surgery of cavernous malformations with and without navigational support--a comparative study.

BACKGROUND: The aim of this descriptive study was the comparison of the clinical and surgical data of patients who suffered from cavernoma and were treated surgically with and without intraoperative navigation (ultrasound, neuronavigation). METHOD: Between 1995 and 2002, 40 patients were treated for cavernous malformations microsurgically: 24 patients (group I) using a neuronavigation system (STP 4.0, SNN, Germany), 7 patients (group II) using ultrasound (Siemens Omnia with 5.0 MHz Probe) and 9 patients (group III) without any image guidance using anatomic landmarks. FINDINGS: With the use of neuronavigation the mean sizes of cavernous malformations, which were resected, were reduced from 25.6 mm (group III) and 24.4 mm (group II) to 16.3 mm (group I) (p > or = 0.05). Corresponding to the reduction of the cavernoma size, the mean distances of the vascular lesion to the cortical surface increased from 13.9 mm (group III) and 17.8 mm (group II) to 24.4 mm under neuronavigational support (p > or = 0.05). All cavernomas were resected completely in all 40 patients. Postoperative neuroradiological control (MRI) confirmed complete resection in all cases. No significant differences in the clinical outcome could be evaluated in all three groups up to three months postoperatively. CONCLUSIONS: Use of neuronavigation was associated with a more comfortable and safer surgery of smaller and more deeper-seated cavernomas. In spite of the lack of significance between all groups, the advantages of neuronavigation in planning and realising surgery could be documented, which justify the additional costs and time-consuming acquisition of planning image data and postprocessing as well as intraoperative navigation.

Adolescent↗

[Mechatronic in functional endoscopic sinus surgery. First experiences with the daVinci Telemanipulatory System].

BACKGROUND: This study examines the advantages and disadvantages of a commercial telemanipulator system (daVinci, Intuitive Surgical, USA) with computer-guided instruments in functional endoscopic sinus surgery (FESS). METHODS: We performed five different surgical FESS steps on 14 anatomical preparation and compared them with conventional FESS. A total of 140 procedures were examined taking into account the following parameters: degrees of freedom (DOF), duration , learning curve, force feedback, human-machine-interface. RESULTS: Telemanipulatory instruments have more DOF available then conventional instrumentation in FESS. The average time consumed by configuration of the telemanipulator is around 9+/-2 min. Missing force feedback is evaluated mainly as a disadvantage of the telemanipulator. Scaling was evaluated as helpful. The ergonomic concept seems to be better than the conventional solution. DISCUSSION: Computer guided instruments showed better results for the available DOF of the instruments. The human-machine-interface is more adaptable and variable then in conventional instrumentation. Motion scaling and indexing are characteristics of the telemanipulator concept which are helpful for FESS in our study.

Clinical Competence↗

Correlation of continuously monitored regional cerebral blood flow and brain tissue oxygen.

BACKGROUND: The purpose of this study was to investigate the relationship between continuously monitored regional cerebral blood flow (CBF) and brain tissue oxygen (PtiO2). METHODS: Continuous advanced multimodal neuromonitoring including monitoring of PtiO2 (Licox, GMS) and CBF (QFlow, Hemedex) was performed in eight patients after severe subarachnoid haemorrhage (n=5) and traumatic brain injury (n=3) for an average of 9.6 days. Parameters were measured using a flexible polarographic PtiO2-probe and a thermal diffusion CBF-microprobe. FINDINGS: Regarding the whole monitoring period in all patients, the data indicated a significant correlation between CBF and PtiO2 (r=0.36). In 72% of 400 analysed intervals of 30 minutes duration with PtiO2 changes larger than 5 mmHg, a strong correlation between CBF and PtiO2 existed (r>0.6). In 19% of intervals a still statistically significant correlation was observed (0.3<r<0.6). During the remaining 9% no correlation was found (r<0.3). Regarding the clinical stability of the monitoring devices, the CBF monitoring system allowed monitoring of CBF in 64% of the time when PtiO2 monitoring was possible only. Phases of non-monitoring were mostly due to fever of the patient, when the system does not allow monitoring to avoid overheating of the cerebral tissue. CONCLUSIONS: This study suggests a correlation between CBF and PtiO2. The level of PtiO2 seems to be predominately determined by regional CBF, since changes in PtiO2 were correlated in 90% of episodes to simultaneous changes of CBF.

Brain↗

Protein expression analysis of chromosome 12 candidate genes in chronic lymphocytic leukemia (CLL).

The pathogenic role of trisomy 12 in chronic lymphocytic leukemia (CLL) remains unresolved, but recently an upregulated RNA expression level has been observed for chromosome 12 candidate genes. In the current study, the protein expression of chromosome 12 candidate genes was characterized by comparing CLL cases with (n=58) or without (n=16) trisomy 12, CD19+-B-cells and cell lines (JVM-2, EHEB, JURKAT). Immunoblotting was performed to quantify the levels of AID, APAF-1, ARF3, CCND2, CDK2, CKD4, GLI, MDM-2, p27, Smac/DIABLO and STAT6 (signal transducer and activator of transcription 6). The cell lines showed distinct expression patterns for CCND2, MDM-2, p27, Smac/DIABLO and STAT6, and displayed higher levels of CDK2 and CDK4 than the CLL cases. JURKAT and the CLL cases expressed uniformly high levels of p27, but low levels of CCND2. AID expression in the CLL cases was weak with slight variations regardless of the subgroup affiliation. The expression of the investigated proteins was independent of the trisomy 12 status as well as of the VH mutation status. The comparison of CD19+-B-cells with CLL revealed higher protein levels in CLL for CDK4, p27, Smac/DIABLO and STAT6. Further studies including protein expression experiments in genetic high-risk subgroups of CLL have to elucidate whether these proteins qualify as candidates for targeted CLL therapies.

Antigens, CD19↗

The first evaluation of brain shift during functional neurosurgery by deformation field analysis.

Stereotactic surgery is based on a high degree of accuracy in defining and localising intracranial targets and placing surgical tools. Brain shift can influence its accuracy significantly. Deep brain stimulation of the subthalamic nucleus can markedly change the quality of life of patients with advanced Parkinson's disease, but the outcome depends on the quality of electrode placement. A patient is reported in whom the placement of the second electrode was not successful. Deformation field analysis of pre- and postoperative three dimensional magnetic resonance images showed an intraoperative brain movement of 2 mm in the region of the subthalamic nucleus (the target point). Electrode repositioning resulted in efficient stimulation effects. This case report shows the need to reduce risk factors for intraoperative brain movement and demonstrates the ability of deformation field analysis to quantify this complication.

Aged↗

Comparison of different fluorescence fluctuation methods for their use in FRET assays: monitoring a protease reaction.

We compare the accuracy of a variety of Fluorescence Fluctuation Spectroscopy (FFS) methods for the study of Förster Resonance Energy Transfer (FRET) assays. As an example, the cleavage of a doubly labeled, FRET-active peptide substrate by the protease Trypsin is monitored and analyzed using methods based on fluorescence intensity, Fluorescence Correlation Spectroscopy (FCS) and Fluorescence Intensity Distribution Analysis (FIDA). The presented fluorescence data are compared to High-Pressure Liquid Chromatography (HPLC) data obtained from the same assay. The HPLC analysis discloses general disadvantages of the FRET approach, such as incomplete labeling and the need for aliquots. However, the simultaneous use of two photon detectors monitoring the fluorescence signal of both labels significantly improves the analysis. In particular, the two global analysis tools Two-Dimensional Fluorescence Intensity Distribution Analysis (2D-FIDA) and Two-Color Global Fluorescence Correlation Spectroscopy (2CG-FCS) highlight the potential of a combination of FFS and FRET. While conventional FIDA and FCS auto- or cross-correlation analysis leaves the user with drawbacks inherent in two-color and FRET applications, these effects are overcome by the global analysis on the molecular level. Furthermore, it is advantageous to analyze the unnormalized as opposed to the normalized correlation data when combining any fluorescence correlation method with FRET, since the analysis of the unnormalized data introduces more accuracy and is less sensitive to the experimental drawbacks.

Algorithms↗

[Preoperative imaging as the basis for image-guided neurosurgery].

With the progressive development of soft- and hardware, the acceptance of image-guided neurosurgery has increased dramatically. Additional image data are required to analyze the nature and the dimensions of pathological processes and the surrounding tissue. In this context, fMRI, SPECT, PET, as well as special modalities of CT and MR imaging, are routinely used. Secondary post-processing options are used to detect intracerebral lesions as well as adjacent functional eloquent regions in the parenchymatous organ pre- and intraoperatively. The integration of different image information guarantees the precise planning and realization of surgical maneuvers. The segmentation of interesting structures and risk structures, as well as their implementation in the neuronavigation systems, help to avoid additional intraoperative traumatization and offer a higher level of safety and precision. In this article the value and limitations of presurgical imaging will be discussed.

Brain↗

Cavernous malformations--navigational supported surgery.

OBJECTIVE: Navigational supported surgery of intracranial lesions is expected to be associated with a lower rate of brain traumatization as well as an avoidance of additional neurological deficits and surgical morbidity. In our study we used the computer-assisted image guidance for resection of cerebral cavernous malformations. METHODS: In all patients the planning procedure for the following image-guided surgery was realized using preoperative MRl data sets and a neuronavigation system (STP 4.0, SNN). In cases in which the cavernoma was situated near functional eloquent regions, functional MR images were fused preoperatively. RESULTS: During the last 24 months, 21 patients were surgically treated for cerebral cavernoma. No patient was operated twice. The mean size of cavernoma was 18.3 mm, ranging from 5 to 60 mm, the mean distance between cortical surface and cavernoma was 26 mm, ranging from 5 to 50 mm. The surgical procedure lasted in the median 180 min. All patients showed an identical or better neurological outcome. CONCLUSIONS: Neuronavigation allows an accurate definition of the intraoperative target, a correct approach and a safe surgery. With the help of neuronavigation the surgical approach and the extirpation of cavernous malformations were realized in a comfortable and safe way and allowed a minimization of tissue manipulation.

Adolescent↗

[Post-processing of radiological data for preoperative planning in skull base surgery].

Preoperative planning in skull base surgery is usually based on numbers of different radiological data. To use this complex data digital post-processing is necessary. There is a significant difference between radiological and surgical post-processing. Planning the approach, resection of the tumour and reconstruction of the defect are supported by the software demonstrated in this study. Integration of the results in a closed workflow of Information-Guided Therapy will increase the potentials of surgical post-processing in the future (i. e. intraoperative navigation and visualization). Evidence based medicine will use digital data of surgical planning.

Carcinoma, Adenoid Cystic↗

Intrinsic tunneling spectra of Bi2(Sr(2-x)Lax)CuO(6+delta).

We have measured intrinsic-tunneling spectra of a single CuO-layer La-doped Bi2(Sr(2-x)Lax)CuO(6+delta) (Bi2201-Lax). Despite a difference of a factor of 3 in the optimal superconducting critical temperatures for Bi2201-La0.4 and Bi2212 (32 and 95 K, respectively) and different spectral energy scales, we find that the pseudogap vanishes at a similar characteristic temperature T* approximately 230-300 K for both compounds. We find also that, in Bi2201-Lax, pseudogap humps are seen as sharp peaks and, in fact, even dominate the intrinsic spectra.

Journal Article↗

Clinical results in MR-guided therapy for malignant gliomas.

The prognostic impact of the extent of tumour resection in surgery of malignant glioma patients remains controversial. We report the results of cumulative survival of malignant glioma patients operated with MR-guidance. Patients with complete tumour removal were compared with a population of patients with incomplete tumour removal. A 0.5 T scanner was used to criticize the extent of resection during surgery. In total no significant difference could be found, however there is a tendency that complete tumour removal seems to be associated with a slightly increased median survival time.

Adult↗

A polymorphism (5-HTTLPR) in the serotonin transporter promoter gene is associated with DSM-IV depression subtypes in seasonal affective disorder.

Serotonergic mechanisms are thought to play an important role in the pathogenesis of seasonal affective disorder (SAD). The expression of the serotonin transporter (5-HTT) is regulated in part by an insertion/deletion polymorphism in the serotonin transporter gene promoter region (5-HTTLPR). The 5-HTTLPR short allele (s) has been associated with anxiety-related personality traits and depression, and one study observed an association between the 5-HTTLPR s-allele and SAD and the trait of seasonality. We genotyped 138 SAD patients and 146 healthy volunteers with low seasonality for 5-HTTLPR. No difference between patients and controls was found for genotype distribution and s-allele frequency. However, genotype distribution and allele frequencies were strongly associated with DSM-IV depression subtypes. Melancholic depression was associated with the 5-HTTLPR long (l) allele and atypical depression with the 5-HTTLPR s-allele (two-sided Fisher's exact test: genotype distribution: P=0.0038; allele frequencies: P=0.007). Our data are compatible with the hypothesis of a disease process that is not causally related to 5-HTTLPR, but involves 5-HT neurotransmission and 5-HTTLPR somewhere on its way to phenotypic disease expression.

Bipolar Disorder↗