PubMed Health⌕ Search

Biomedical subjects

Dae Sung Yoon

Publications and source records attributed to Dae Sung Yoon.

5 recordsLinked to original sources

Novel electrical detection of label-free disease marker proteins using piezoresistive self-sensing micro-cantilevers.

We report an electro-mechanical biosensor for electrical detection of proteins with disease markers using self-sensing piezoresistive micro-cantilevers. Electrical detection, via surface stress changes, of antigen-antibody (Ag-Ab) specific binding was accomplished through a direct nano-mechanical response of micro-fabricated self-sensing micro-cantilevers. A piezoresistive sensor measures the film resistance variation with respect to surface stress caused by biomolecules specific binding. When specific binding occurred on a functionalized Au surface, surface stress was induced throughout the cantilever, resulting in cantilever bending and resistance change of the piezoresistive layer. The cantilever biosensors were used for the detection of prostate specific antigen (PSA) and C-reactive proteins (CRP), which are a specific marker of prostate cancer and cardiac disease. From the above experiment, it was revealed that the sensor output voltage was proportional to the injected antigen concentration (without antigen, 10 ng/ml, 100 ng/ml, 1 microg/ml). PSA and CRP antibodies were found to be very specific for their antigens, respectively. This indicated that the self-sensing micro-cantilever approach is beneficial for detecting disease markers, and our piezoresistive micro-cantilever sensor system is applicable to miniaturized biosensor systems.

Biomarkers↗

Immunoassay of prostate-specific antigen (PSA) using resonant frequency shift of piezoelectric nanomechanical microcantilever.

We designed and fabricated the nanomechanical Pb(Zr0.52Ti0.48)O3 (PZT) cantilever; we demonstrated a novel electrical measurement, under a controlled ambient temperature and humidity, for label-free detection of a prostate-specific antigen (PSA); and we achieved a detection sensitivity as low as 10 pg/ml. For the fabrication of our nanomechanical PZT cantilevers, we used composite layers of Ta/Pt/PZT/Pt/SiO2 on a SiN(x) supporting layer for electrical self-sensing without external oscillators. This method allows PSA proteins to be detected via a simple electrical measurement of the resonant frequency change generated by the molecular interaction of the antigen (Ag) and the antibody (Ab). The resonant frequency shifted due to the specific binding of the PSA Ag to its Ab which is immobilized via calixcrown self-assembled monolayers on an Au surface deposited on a nanomechanical PZT cantilever. We determined the resonant frequency shift as the value of -172 Hz and -273 Hz, when the concentration of PSA Ag was 1 ng/ml, with the cantilever dimensions of 100 microm x 300 microm and 50 microm x 150 microm, respectively. Theoretical and experimental analysis suggests that the minimum detectable sensitivity for a resonant frequency shift due to a PSA Ag-Ab interaction depends on the dimensions of the nanomechanical PZT cantilever. These results also demonstrate that the experimentally measured resonant frequency shift is larger than that calculated theoretically due to the compressive stress of the PSA Ag-Ab interaction.

Biomarkers, Tumor↗

AC frequency characteristics of coplanar impedance sensors as design parameters.

Glass-based microchannel chips were fabricated using photolithographic technology, and Pt thin-film microelectrodes, as coplanar impedance sensors, were integrated on them. Longitudinal design parameters, such as interelectrode spacing and electrode width, of coplanar impedance sensors were changed to determine AC frequency characteristics as design parameters. Through developing total impedance equations and modeling equivalent circuits, the dominant components in each frequency region were illustrated for coplanar impedance sensors and the measured results were compared with fitted values. As the ionic concentration increased, the value of the frequency-independent region decreased and cut-off frequencies increased. As the interelectrode spacing increased, cut-off frequencies decreased and total impedance increased. However, the width of each frequency-independent region was similar. As the electrode area increased, f(low) decreased but f(high) was fixed. We think that the decrease in R(Sol) dominated over the influence of other components, which resulted in heightening f(low) and f(high). The interelectrode spacing is a more significant parameter than the electrode area in the frequency characteristics of coplanar sensors. The deviation of experimentally obtained results from theoretically predicted values may result from the fringing effect of coplanar electrode structure and parasitic capacitance due to dielectric substrates. We suggest the guidelines of dominant components for sensing as design parameters.

Biosensing Techniques↗

In-situ quantitative analysis of a prostate-specific antigen (PSA) using a nanomechanical PZT cantilever.

We report on a novel technique of resonant frequency shift measurement based on a nanomechanical cantilever with a PZT actuating layer for label-free detection of a prostate-specific antigen (PSA) in a liquid environment. The nanomechanical PZT thin film cantilever is composed of SiO(2)/Ta/Pt/PZT/Pt/SiO(2) on a SiN(x) supporting layer for simultaneous self-exciting and sensing; it was fabricated using a standard MEMS (micro electromechanical system) process. The specific binding characteristics of the PSA antigen to its antibody, which is immobilized with Calixcrown self-assembled monolayers (SAMs) on a gold surface deposited on a cantilever, are determined to a high sensitivity. For the bioassay in a liquid environment, a liquid test cell with a 20 microl volume reaction chamber has been fabricated, using a bonding technique between poly(dimethyl siloxane) (PDMS) bilayers. An observed trend of resonant frequency change with respect to time could be explained by the binding kinetics due to the Langmuir isotherm and diffusion and by the effects of a small volume reaction chamber. In the saturated regimes, the resonant frequency of the cantilever increased with increase of the PSA concentration in the reaction chamber, showing that the trend of the resonance frequency change was similar to that of the fluorescence results. The saturated resonance frequency shift of the cantilever was proportional to the PSA antigen concentration of analyte solution.

Antibodies↗

DNA hybridization electrochemical sensor using conducting polymer.

We report the use of poly(thiophen-3-yl-acetic acid 1,3-dioxo-1,3-dihydro-isoindol-2-yl ester (PTAE) for application to electrochemical hybridization sensor. A synthetic route for the thiophen-3-yl-acetic acid 1,3-dioxo-1,3-dihydro-isoindol-2-yl ester (TAE) is described, which is used as a monomer of conducting polymer sensor. A direct chemical substitution of probe oligonucleotide to good leaving group site in the PTAE is carried out on the conducting polymer film. A biological recognition can be monitored by comparison with the electrochemical signal (cyclic voltammogram) of single and double strand state oligonucleotide. The sensitivity of the electrochemical sensor is 0.62 microA/nmole and the detection limit is 1 nmole. The oxidation current of double strand state oligonucleotide is a half of that of single strand, that is corresponding to the decrease of electrochemical activity of conducting polymer with increase of stiffness of side group of the polymer. The oxidation current decreasing ratios of perfect matched and single nucleotide mismatched samples are 52 and 25-30%, respectively. The more decreasing ratio is attributable to the more steric hindrance of single nucleotide mismatched sample.

Biosensing Techniques↗