PubMed Health⌕ Search

Biomedical subjects

Dale W Esliger

Publications and source records attributed to Dale W Esliger.

2 recordsLinked to original sources

Technical reliability assessment of three accelerometer models in a mechanical setup.

PURPOSE: To determine which of the three most commonly used accelerometer models has the best intra- and interinstrument reliability using a mechanical laboratory setup. Secondly, to determine the effects that acceleration and frequency have on these reliability measures. METHODS: Three experiments were performed. In the first, five each of the Actical, Actigraph, and RT3 accelerometers were placed on a hydraulic shaker plate and simultaneously accelerated in the vertical plane at varying accelerations and frequencies. Six different conditions of varying intensity were used to produce a range of accelerometer counts. Reliability was calculated using standard deviation, standard error of the measurement, coefficient of variation, and intraclass correlation coefficients. In the second and third experiments, 39 Actical and 50 Actigraph accelerometers were put through the same six conditions. RESULTS: Experiment 1 showed poor reliability in the RT3 (intra- and interinstrument CV > 40%). Experiments 2 and 3 clearly indicated that the Actical (CVintra = 0.5%, CVinter = 5.4%) was more reliable than the Actigraph (CVintra = 3.2%, CVinter = 8.6%). Variability in the Actical was negatively related to the acceleration of the condition, whereas no relationship was found between acceleration and reliability in the Actigraph. Variability in the Actigraph was negatively related to the frequency of the condition, whereas no relationship was found between frequency and reliability in the Actical. CONCLUSION: Of the three accelerometer models measured in this study, the Actical had the best intra- and interinstrument reliability. However, discrepant trends in the variability of Actical and Actigraph counts across accelerations and frequencies preclude the selection of a superior model. More work is needed to understand why accelerometers designed to measure the same thing behave so differently.

Acceleration↗

Conquering childhood inactivity: is the answer in the past?

PURPOSE: The primary purpose of this study was to compare the health-related physical fitness and physical activity behaviors of Old Order Mennonite children to both rural and urban-dwelling children living a contemporary Canadian lifestyle. METHODS: A cross-sectional study design was used to compare the physical fitness and physical activity characteristics of three groups of children between the ages of 8-13 yr. A total of 124 Old Order Mennonite children (OOM) from Ontario, Canada, were compared with contemporary living children from urban (USK, N = 110) and rural (RSK, N = 165) Saskatchewan, Canada. Fitness was assessed using measures of height, weight, triceps skinfold, grip strength, push-ups, partial curl-ups, and aerobic fitness. Physical activity levels were directly measured for seven consecutive days using a MTI Actigraph accelerometer model 7164. RESULTS: After controlling for maturational age, analyses revealed that OOM children had a smaller triceps skinfold than USK children (P < 0.01), a greater aerobic fitness score than RSK children (P < 0.05), and greater grip strength than both RSK and USK children (P < 0.001). The OOM children also accumulated more minutes of MVPA per day than RSK or USK groups (P < 0.001). CONCLUSION: This research demonstrates that OOM children tend to be leaner, stronger and more active than urban and rural dwelling children living a contemporary Canadian lifestyle despite having no physical education, no institutionalized sport, and low socioeconomic status. These findings support the notion that that contemporary living may facilitate a decline in fitness and physical activity among some Canadian children.

Adolescent↗