PubMed Health⌕ Search

Biomedical subjects

Damià Barceló

Publications and source records attributed to Damià Barceló.

At least 37 records · Page 2Linked to original sources

Environmental analysis of fluorinated alkyl substances by liquid chromatography-(tandem) mass spectrometry: a review.

Fluorinated alkyl substances (FASs) are widely distributed contaminants that have been found in many environmental, human and biological samples throughout the world. Perfluorochemicals are used in many industry and consumer products, such as polymers and surfactants, because they have unique and useful properties (they are stable, chemically inert and generally unreactive). However, these compounds have also been found to be toxic, persistent and bioaccumulative. In recent years various analytical methods have been developed for the analysis of FASs in environmental samples. Most of these methods are based on liquid chromatography coupled to mass spectrometry (LC-MS) or tandem mass spectrometry (LC-MS/MS), since this is considered to be the technique of choice. This article reviews the various LC-(tandem)MS methods described so far for the analysis of FASs in water, sediment, sludge and biota samples. It discusses the main experimental conditions used for sample pretreatment and for analysis as well as the most relevant problems encountered and the limits of detection achieved.

Alkylation↗

Determination of antimicrobial residues and metabolites in the aquatic environment by liquid chromatography tandem mass spectrometry.

Antimicrobials are used in large quantities in human and veterinary medicine. Their environmental occurrence is of particular concern due to the potential spread and maintenance of bacterial resistance. After intake by the organisms, the unchanged drug and its metabolized forms are excreted and enter wastewater treatment plants where they are mostly incompletely eliminated, and are therefore eventually released into the aquatic environment. The reliable detection of several antimicrobials in different environmental aqueous compartments is the result of great improvements achieved in analytical chemistry. This article provides an overview of the more outstanding analytical methods based on liquid chromatography tandem mass spectrometry, developed and applied to determine antimicrobial residues and metabolites present in surface, waste, and ground waters.

Anti-Bacterial Agents↗

Evaluating the interactions of vertebrate receptors with persistent pollutants and antifouling pesticides using recombinant yeast assays.

The development of in vitro methods for screening potentially harmful biological activities of new compounds is an extremely important way to increase not only their intrinsic environmental safety, but also the public perception of the safety standards associated with them. In this work we use two yeast systems to test the ability of different chemicals to bind and activate two vertebrate receptors which are intimately related to adverse biological effects of pollution in exposed fauna: the estrogen receptor (ER) and the aryl hydrocarbon receptor (AhR). The panel of compounds analysed here includes well-known pollutants, like PCBs, pp'-DDT and hexachlorobenzene, together with the less-known, emerging putative pollutants, such as Sea-Nine, Irgarol and diuron. Results show the ability of some of these compounds to interact with one or both receptors, provide hints about the relationship between structure and activity, and suggest mechanistic explanations for the biological activities already described in whole-animal experiments. In addition, we show that AhR may have an intrinsic ligand promiscuity comparable to that of ER, a feature not fully appreciated in the past due to the technical difficulties involved with testing highly lipophilic substances in yeast-based assays.

Animals↗

Biodegradation studies of selected priority acidic pesticides and diclofenac in different bioreactors.

The biodegradation of selected priority acidic pesticides MCPP, MCPA, 2,4-D, 2,4-DP and bentazone and the acidic pharmaceutical diclofenac was investigated using a membrane bioreactor (MBR) and a fixed-bed bioreactor (FBBR). A pilot plant MBR was fed with raw water spiked with the selected compounds. The experiment was repeated every week during four weeks to enhance the adaptation of microorganisms. In order to further study the biodegradability of these compounds, degradation studies in a FBBR were carried out. All the samples were analysed by solid phase extraction-gas chromatography-mass spectrometry (SPE-GC-MS). The results indicate that in the MBR compounds except for bentazone were eliminated within the first day of the experiment at rates ranging from 44% to 85%. Comparing these results with the degradation rates in the FBBR showed that in the latter only MCPP, MCPA 2,4-D and 2,4-DP were degraded after a much longer adaptation phase of microorganisms.

Bacteria↗

Chemometrical investigation of the presence and distribution of organochlorine and polyaromatic compounds in sediments of the Ebro River Basin.

A multivariate statistical data analysis, using principal component analysis, of historical data from 1996 to 2003 concerning the concentration of different polycyclic aromatic hydrocarbons and organochlorine compounds in sediment samples from different sampling sites of the Ebro River Basin was performed under the UE funded project AQUATERRA. Three major contamination sources were identified and their composition and distribution profiles were resolved. The first contamination profile was mostly loaded by polycyclic aromatic hydrocarbons, the second contamination profile was loaded by some organochlorine compounds and the third contamination profile was more specifically loaded by naphthalene. Samples from the different geographical regions of the Ebro River Basin were grouped according to the contamination described by these three major profiles.

Europe↗

Analysis of polycyclic aromatic hydrocarbons in pine needles by gas chromatography-mass spectrometry: comparison of different extraction and clean-up procedures.

Three extraction methodologies (Soxhlet, ultrasonic and pressurized liquid extraction) and several clean-up procedures (Florisil, silica and alumina in cartridges or glass column format) were tested and compared to extract 16 US Environmental Protection Agency (EPA) polycyclic aromatic hydrocarbons (PAHs) from Pinus pinea L. needles. Quantification was done by gas chromatography with mass spectrometry, by internal standard method using five deuterated PAH surrogate standards. Among the several extraction and clean-up procedures tested, ultrasonic extraction followed by alumina cartridge clean-up was the preferred method, yielding recoveries between 72 and 100% and limits of detection between 0.22 and 0.71 ng/g dry weight. The performance of the method was tested to determine PAHs in naturally contaminated samples.

Chemical Fractionation↗

Determination of pharmaceuticals of various therapeutic classes by solid-phase extraction and liquid chromatography-tandem mass spectrometry analysis in hospital effluent wastewaters.

A multi-residue analytical method has been developed and validated for determining a selection of 16 pharmaceuticals: the anti-epileptic carbamazepine, seven analgesic/anti-inflammatory drugs (mefenamic acid, indomethacine, ibuprofen, naproxen, diclofenac, ketorolac and acetaminophen), the analgesic opiate codeine, two antidepressants (fluoxetine and paroxetine), beta-blockers (atenolol and propranolol), antibiotic (trimethoprim, metronidazole, and erythromycin) and the anti-ulcer ranitidine in hospital effluent wastewaters. The method allows simultaneous extraction of the pharmaceuticals compounds by solid-phase extraction (SPE) using the Waters Oasis HLB at pH 7. The analytes were then identified and quantitatively determined by liquid chromatography-tandem mass spectrometry (LC-MS-MS) using multiple reaction monitoring (MRM). Recoveries of the pharmaceuticals were higher than 75%, with the exception of ranitidine (45%) and the overall variability of the method was below 9%. The instrumental detection limit (IDL) varied between 2 and 31 pg injected, the method detection limit (LOD) was between 7 and 47 ng/L in spiked hospital effluent. The precision of the method, calculated as relative standard deviation (RSD), ranged from 0.3 to 4.9%. A detail study off matrix effect is included in this work, regarding to signal suppression in these effluent wastewaters from a hospital complex samples. The developed analytical method was applied for preliminary data results in effluent wastewaters from a hospital.

Adrenergic beta-Antagonists↗

Determination of benzoxazinone derivatives in plants by combining pressurized liquid extraction-solid-phase extraction followed by liquid chromatography-electrospray mass spectrometry.

A new analytical method based on the use of pressurized liquid extraction (PLE) followed by solid-phase extraction with LiChrolut RP C18 cartridges was evaluated for the sample preparation, extraction, and cleanup of eight naturally occurring benzoxazinone derivatives, 2-beta-D-glucopyranosyloxy-4-hydroxy-1,4-benzoxazin-3-one, 2-beta-D-glucopyranosyloxy-4-hydroxy-7-methoxy-1,4-benzoxazin-3-one, 2,4-dihydroxy-1,4-benzoxazin-3-one (DIBOA), 2,4-dihydroxy-7-methoxy-1,4-benzoxazin-3-one, 2-hydroxy-1,4-benzoxazin-3-one, 2-hydroxy-7-methoxy-1,4-benzoxazin-3-one, benzoxazolin-2-one, and 6-methoxybenzoxazolin-2-one in plant samples. Afterward, liquid chromatography-electrospray mass spectrometry, using the selected ion monitoring mode and internal standard (2-MeO-DIBOA, indoxyl-beta-D-glucoside, and quercetin-3-O-rutinoside) quantification method was performed. This paper demonstrates the effectiveness of the PLE method, in conjunction with sensitive and specific mass spectrometric detection, for the quantitative recovery of compounds of the benzoxazinone class from plants. The recoveries of the analytes ranged from 66 to 110% with coefficients of variation ranging from 1 to 14%. This method gave detection limits between 1 and 27 microg/g. The method was applied to foliage and roots of three different wheat cultivars, and the analytes were detected in the range of 11-3261 microg/g of dry weight.

Benzoxazines↗

Benzoxazinoid allelochemicals in wheat: distribution among foliage, roots, and seeds.

In this study, the distribution of eight allelochemicals among the foliage, roots, and seeds of different wheat varieties is reported for two different sampling campaigns, corresponding to two consecutive years. The determination of benzoxazinoid derivatives was performed by combining pressurized liquid extraction--solid-phase extraction followed by liquid chromatography--electrospray mass spectrometry. To the authors' knowledge, there are no previous works about the content of allelochemicals in seed tissue of germinated wheat seedlings. Allelochemicals found in seeds were detected at levels similar to those found in foliage and roots. The results showed that the type of metabolites detected depends strongly on the working up procedure of the plant material, as well as of plant growth stage. A general decrease of the total amount of allelochemical content in the plants was observed with plant age. There was a significant difference in the total amount of benzoxazinoid derivatives in the different wheat varieties analyzed.

Benzoxazines↗

Pilot survey of a broad range of priority pollutants in sediment and fish from the Ebro river basin (NE Spain).

Priority organic pollutants were investigated in sediments and fish collected along the Ebro river basin (NE Spain) to evaluate their occurrence, transport and bioavailability. Sediments were collected in 18 sites and two species of fish were captured in nine sites according to the availability in each area. The sampling sites covered industrial, urban and agricultural areas. Four methods were used to detect 20 organochlorine compounds (OCs), 8 polycyclic aromatic hydrocarbons, 3 organotin compounds, 2 alkylphenols and 40 polybrominated diphenyl ethers (PBDEs) from purified extracts. The contamination pattern was site specific and no downstream increase in concentration of pollutants was observed but rather a generalized low level diffuse pollution. Target compounds were detected in sediments at 0.01 to 2331 microg/kg dry weight, and only OCs and PBDEs were accumulated in benthopelagic fish. Toxicological assessment was performed according to predicted environmental levels and revealed sites where adverse effects could occur.

Animals↗

Fully automated multianalyte determination of different classes of pesticides, at picogram per litre levels in water, by on-line solid-phase extraction-liquid chromatography-electrospray-tandem mass spectrometry.

This paper reports the development of a fully automated method for the multianalyte determination of twenty pesticides belonging to different classes (triazines, phenylureas, organophosphates, anilines, acidic, propanil, and molinate) in natural and treated waters. The method, based on on-line solid-phase extraction-liquid chromatography-electrospray-tandem mass spectrometry, is highly sensitive (limits of detection between 0.004 and 2.8 ng L(-1)), precise (relative standard deviations between 2.0 and 12.1%), reliable (two selected reaction-monitoring transitions are monitored per compound), rapid (45 min per sample), and simple. The application of this method to the monitoring of the target compounds in a waterworks revealed the presence of the pesticides investigated at concentrations up to 516 and 82 ng L(-1) (total pesticide concentration) in river water and ground water, respectively, used as sources, and their gradual removal through the purification process.

Automation↗

Liquid chromatography-tandem mass spectrometry for the analysis of pharmaceutical residues in environmental samples: a review.

Pharmaceutical residues are environmental contaminants of recent concern and the requirements for analytical methods are mainly dictated by low concentrations found in aqueous and solid environmental samples. In the current article, a review of the liquid chromatography-tandem mass spectrometry (LC-MS/MS) based methods published so far for the determination of pharmaceuticals in the environment is presented. Pharmaceuticals included in this review are antibiotics, non-steroidal anti-inflammatory drugs, beta-blockers, lipid regulating agents and psychiatric drugs. Advanced aspects of current LC-MS/MS methodology, including sample preparation and matrix effects, are discussed.

Chromatography, Liquid↗

Application of liquid chromatography-electrospray-tandem mass spectrometry for the identification and characterisation of linear alkylbenzene sulfonates and sulfophenyl carboxylates in sludge-amended soils.

A novel procedure was developed for the simultaneous determination of linear alkylbenzene sulfonates (LAS) and their major metabolites, sulfophenyl carboxylates (SPC), in sludge-amended soil. After pressurised liquid extraction with methanol/water (90:10) and a clean-up on C18 solid-phase extraction cartridges, final analysis was done by ion-pair liquid chromatography-electrospray-tandem mass spectrometry (LC-ESI-MS/MS). With this method, SPC with 5-13 carbon atoms in the aliphatic side chain were identified for the first time in agricultural soils treated with sewage sludge. Quantification of LAS and SPC in soil from 10 field sites, which differed in the history of sludge application, gave total concentrations of 120-2840 microg kg(-1) for LAS and of 4-220 microg kg(-1) for SPC. The data provided evidence for rapid biodegradation of LAS in the initial phase after sludge amendment with a transitory build-up of high concentrations of, mainly, short-chain SPC. Trace amounts of residual LAS and SPC were detected in soils having received the last sludge treatment 10 days to 4 years prior to sampling.

Carboxylic Acids↗

Automated water analyser computer supported system (AWACSS) Part I: Project objectives, basic technology, immunoassay development, software design and networking.

A novel analytical system AWACSS (automated water analyser computer-supported system) based on immunochemical technology has been developed that can measure several organic pollutants at low nanogram per litre level in a single few-minutes analysis without any prior sample pre-concentration nor pre-treatment steps. Having in mind actual needs of water-sector managers related to the implementation of the Drinking Water Directive (DWD) (98/83/EC, 1998) and Water Framework Directive WFD (2000/60/EC, 2000), drinking, ground, surface, and waste waters were major media used for the evaluation of the system performance. The instrument was equipped with remote control and surveillance facilities. The system's software allows for the internet-based networking between the measurement and control stations, global management, trend analysis, and early-warning applications. The experience of water laboratories has been utilised at the design of the instrument's hardware and software in order to make the system rugged and user-friendly. Several market surveys were conducted during the project to assess the applicability of the final system. A web-based AWACSS database was created for automated evaluation and storage of the obtained data in a format compatible with major databases of environmental organic pollutants in Europe. This first part article gives the reader an overview of the aims and scope of the AWACSS project as well as details about basic technology, immunoassays, software, and networking developed and utilised within the research project. The second part article reports on the system performance, first real sample measurements, and an international collaborative trial (inter-laboratory tests) to compare the biosensor with conventional anayltical methods.

Algorithms↗

Automated Water Analyser Computer Supported System (AWACSS) Part II: Intelligent, remote-controlled, cost-effective, on-line, water-monitoring measurement system.

A novel analytical system AWACSS (Automated Water Analyser Computer Supported System) based on immunochemical technology has been evaluated that can measure several organic pollutants at low nanogram per litre level in a single few-minutes analysis without any prior sample pre-concentration or pre-treatment steps. Having in mind actual needs of water-sector managers related to the implementation of the Drinking Water Directive (DWD) [98/83/EC, 1998. Council Directive (98/83/EC) of 3 November 1998 relating to the quality of water intended for human consumption. Off. J. Eur. Commun. L330, 32-54] and Water Framework Directive (WFD) [2000/60/EC, 2000. Directive 2000/60/EC of the European Parliament and of the Council of 23 October 2000 establishing a framework for Community action in the field of water policy. Off. J. Eur. Commun. L327, 1-72], drinking, ground, surface, and waste waters were major media used for the evaluation of the system performance. The first part article gave the reader an overview of the aims and scope of the AWACSS project as well as details about basic technology, immunoassays, software, and networking developed and utilised within the research project. The second part reports on the system performance, first real sample measurements, and an international collaborative trial (inter-laboratory tests) to compare the biosensor with conventional anayltical methods. The systems' capability for analysing a wide range of environmental organic micro-pollutants, such as modern pesticides, endocrine disrupting compounds and pharmaceuticals in surface, ground, drinking and waste water is shown. In addition, a protocol using reconstitution of extracts of solid samples, developed and applied for analysis of river sediments and food samples, is presented. Finally, the overall performance of the AWACSS system in comparison to the conventional analytical techniques, which included liquid and gas chromatographic systems with diode-array UV and mass spectrometric detectors, was successfully tested in an inter-laboratory collaborative trial among six project partners.

Algorithms↗