PubMed Health⌕ Search

Biomedical subjects

Damia Barcelo

Publications and source records attributed to Damia Barcelo.

6 recordsLinked to original sources

Comparison of sulfonated and other micropollutants removal in membrane bioreactor and conventional wastewater treatment.

Membrane bioreactors (MBRs) were compared with conventional activated sludge systems (CAS) for micropollutant degradation, in laboratory-scale spiking experiments with synthetic and real domestic wastewater. The target micropollutants were polar in nature and represented a broad range in biodegradability. The experimental data indicated that MBR treatment could significantly enhance removal of the micropollutants 1,6- and 2,7-naphthalene disulfonate (NDSA) and benzothiazole-2-sulfonate. 1,5-NDSA, EDTA and diclofenac were not removed in either the MBR or the CAS. The other compounds were equally well degraded in both systems. For 1,3-naphthalene disulfonate, the existence of a minimum threshold level for degradation could be demonstrated. Although MBRs could not always make a difference in the overall removal efficiencies achieved, they showed reduced lag phases for degradation and a stronger memory effect, which implies that they may respond quicker to variable influent concentrations. Finally, micropollutant removal also turned out to be less sensitive to system operational variables.

Biodegradation, Environmental↗

Polar pollutants entry into the water cycle by municipal wastewater: a European perspective.

The effluents of eight municipal wastewater treatment plants (WWTP) in Western Europe were analyzed by liquid-chromatography-mass spectrometry for the occurrence of 36 polar pollutants, comprising household and industrial chemicals, pharmaceuticals, and personal care products. In a long-term study of the effluents of three WWTP over 10 months, sulfophenyl carboxylates and ethylene diamino tetraacetate (EDTA) were detected above 10 microg/L on average, while benzotriazoles, benzothiazole-2-sulfonate, diclofenac, and carbamazepine showed mean concentrations of 1-10 microg/L, followed by some flame retardants, naphthalene disulfonates, and personal care products in the range of 0.1-1 microg/L. Half of the determined compounds were not significantly removed in tertiary wastewater treatment. By dividing the effluent concentration of a compound by its relative removal in WWTP a water cycle spreading index (WCSI) was calculated for each compound. We propose that this index provides a measure for the potential of a polar compound to spread along a partially closed water cycle after discharge with municipal wastewater and to occur in raw waters used for drinking water production. Polar pollutants in surface water samples of different catchments showed increasing concentration for compounds with increasing WCSI.

Europe↗

Multi-residue analysis of pharmaceuticals in wastewater by ultra-performance liquid chromatography-quadrupole-time-of-flight mass spectrometry.

In this work, a new multi-residue method using ultra-performance liquid chromatography (UPLC) quadrupole-time-of-flight mass spectrometry (Q-TOF-MS) was developed for screening and confirmation of 29 pharmaceutical compounds belonging to different therapeutical classes: analgesics and antiinflammatories, lipid regulating agents cholesterol lowering statin agents, psychiatric drugs, anti ulcer agents, histamine H2 receptor antagonist, antibiotics and beta-blockers. UPLC uses columns packed with 1.7 microm particles and enables elution of sample components in much narrower, more concentrated bands, resulting in better chromatographic resolution and increased peak height. The typical peak width was 5-10s at base, permitting very good separation of all compounds in 10 min, which represented an approximate three-fold reduction in the analysis time in comparison to conventional high-performance liquid chromatography (HPLC). Unequivocal identification of target pharmaceutical compounds was based on accurate mass measurement of the molecular ions in the TOF mode and by performing collision induced dissociation (CID) in the Q-TOF mode in order to generate accurate mass measurement of the product ions. Using lock mass correction the accurate masses calculated for the product ions deviated from the theoretical masses by 0.2 to 1.3 mDa (root mean square (RMS) value=0.67) and 0.7-6.4 ppm (RMS=3.53), respectively. Quantitation was carried out working in the TOF mode using the narrow window extracted ion chromatograms (nwXICs) of each compound (extracted using a 20 mDa window) yielding relative standard deviation (RSD) from 0.5 to 5.3% (run-to-run) and from 2.1 to 9.1% (day-to-day) and instrumental detection limits (IDLs) from 1 to 200 pg. Analysis of wastewater treatment plant (WWTP) samples gave method detection limits (MDLs) ranging from 10 to 500 ng/L. The UPLC-Q-TOF method was successfully applied to analyze pharmaceutical residues in WWTP samples.

Chromatography, High Pressure Liquid↗

Brominated flame retardants in Alburnus alburnus from Cinca River Basin (Spain).

Thirty-two bleak fish (Alburnus alburnus) from three places along the Spanish River Cinca, a tributary of Ebro River, were collected for polybrominated diphenyl ether (PBDE) and hexabromocyclododecane (HBCD) determinations. Sampling sites corresponded to up- and downstream from Monzon, a heavily industrialized town draining to the river. Four different PBDE congeners (BDE-47, -153, -154 and -183) and HBCD were found at levels ranging from not detected (nd) to 573 ng/g wet weight for total PBDEs and from nd to 1643 ng/g wet weight for HBCD. The lowest values were found upstream of the industrialized area. Concentrations in fish were compared with previous data in sediment samples collected at the same sampling sites, and large fish to sediment ratios for these brominated compounds indicate that they are highly bioavailable. Moreover, PBDE and HBCD concentrations are correlated with fish length and weight indicating the bioaccumulation of these contaminants.

Animals↗

Occurrence of polybrominated diphenylethers, polychlorinated dibenzo-p-dioxins, dibenzofurans and biphenyls in coastal sediments from Spain.

Fifteen sediment samples were analysed in order to determine their content of polybrominated diphenylethers (PBDEs), polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs) and biphenyls (PCBs). Samples were collected from several hot spots on the Spanish coast, such as the harbours of Almeria and Tarragona, and the mouths of the Besos and Llobregat rivers in Barcelona. A generic analytical procedure based on Soxhlet extraction followed by an automated cleanup system and gas chromatography-ion trap-mass spectrometry was employed for determining the toxic congeners of PCDDs and PCDFs, as well as dioxin-like PCBs. As regards PBDE determinations, a rapid method based on the use of selective pressurized liquid extraction followed by gas chromatography-negative ion chemical ionization-mass spectrometry was applied. Total toxicity equivalent (WHO-TEQ) values were calculated using the toxicity equivalent factors proposed by WHO for dioxin-like PCBs, PCDDs and PCDFs. WHO-TEQ values ranged from 0.3 to 75 pg/g dry weight (dw), with PCB contribution on the toxicity of the samples between 1 and 84%. Total PBDE levels ranged from 2.7 to 134 ng/g dw, with BDE-209 contribution on the total PBDE contamination between 50 and 99%.

Benzofurans↗

Column-switching system with restricted access pre-column packing for an integrated sample cleanup and liquid chromatographic-mass spectrometric analysis of alkylphenolic compounds and steroid sex hormones in sediment.

A novel methodology based on column switching LC-MS, using restricted access material (RAM), for an integrated sample clean-up and analysis of endocrine disrupting compounds in sediment samples is described. The use of RAM precolumns, that combines size exclusion and reversed-phase retention mechanisms, enables fast on-line clean-up of sediment extracts and sensitive determination of alkylphenolic compounds, bisphenol A and steroid sex hormones at low ppb level (LODs=0.5-5 ng/g). Different LiChrospher ADS RAM precolumns (Merck, Germany) with C4, C8 and C18, respectively, modification of inner pore surface were tested. ADS C4 precolumns gave the best results in terms of recovery, selectivity and sensitivity, eliminating efficiently matrix components and consequently reducing ion suppression effects. Except for the most polar compounds, all compounds exhibit complete recovery with RSD from 0.87 to 15%. A complete analysis, including efficient pressurized liquid extraction (PLE) of target compounds, on-line clean-up, chromatographic separation and MS detection takes approximately 2 h, which is a significant improvement in comparison to the methods reported previously.

Chromatography, Liquid↗