PubMed Health⌕ Search

Biomedical subjects

Dan Z Reinstein

Publications and source records attributed to Dan Z Reinstein.

17 recordsLinked to original sources

Artemis very high-frequency digital ultrasound-guided repositioning of a free cap after laser in situ keratomileusis.

We present a patient in whom a symmetrically round free cap occurred during laser in situ keratomileusis (LASIK), and flap repositioning was performed without laser ablation. A loss of 3 lines of best spectacle-corrected visual acuity (BSCVA), monocular diplopia, and topographic irregular astigmatism confirmed that the free cap orientation was incorrect. Two subsequent free cap rotations based on refraction failed to realign the free cap into its original position. Artemis 3-dimensional very high-frequency digital ultrasound analysis found the thickness profiles of the free cap and bed to be irregular and mismatched. The rotation required for anatomic realignment was determined by digitally generating a "lock and key" superimposition of the free cap and stromal bed thickness profiles. After Artemis-guided free cap rotation, the eye regained preoperative BSCVA and symmetrical corneal topography with a +0.50 diopter change in spherical equivalent.

Adult↗

Combined Artemis very high-frequency digital ultrasound-assisted transepithelial phototherapeutic keratectomy and wavefront-guided treatment following multiple corneal refractive procedures.

We present a patient with severe visual symptoms following multiple corneal refractive procedures including automated lamellar keratoplasty, arcuate keratotomy, laser in situ keratomileusis (LASIK), LASIK enhancement by cutting another flap, followed by a further LASIK enhancement by flap lifting. Topography was irregularly irregular, and the best spectacle-corrected visual acuity (BSCVA) was 20/25. Artemis very high-frequency digital ultrasound (US) analysis of the anatomical irregularities of the epithelium and stroma was used in conjunction with the topography to determine the cause of the visual symptoms. Very high-frequency digital US-assisted transepithelial phototherapeutic keratectomy together with a wavefront-guided treatment was used to reduce the stromal surface irregularities and the higher-order aberrations (HOAs), respectively. The treatment successfully regularized the stromal surface, dramatically reduced the HOAs, improved the contrast sensitivity to the high normal range, and improved the BSCVA to 20/20.

Contrast Sensitivity↗

Accuracy, repeatability, and reproducibility of Artemis very high-frequency digital ultrasound arc-scan lateral dimension measurements.

PURPOSE: To determine the accuracy, repeatability, and reproducibility of measurement of lateral dimensions using the Artemis (Ultralink LLC) very high-frequency (VHF) digital ultrasound (US) arc scanner. SETTING: London Vision Clinic, London, United Kingdom. METHODS: A test object was measured first with a micrometer and then with the Artemis arc scanner. Five sets of 10 consecutive B-scans of the test object were performed with the scanner. The test object was removed from the system between each scan set. One expert observer and one newly trained observer separately measured the lateral dimension of the test object. Two-factor analysis of variance was performed. The accuracy was calculated as the average bias of the scan set averages. The repeatability and reproducibility coefficients were calculated. The coefficient of variation (CV) was calculated for repeatability and reproducibility. RESULTS: The test object was measured to be 10.80 mm wide. The mean lateral dimension bias was 0.00 mm. The repeatability coefficient was 0.114 mm. The reproducibility coefficient was 0.026 mm. The repeatability CV was 0.38%, and the reproducibility CV was 0.09%. There was no statistically significant variation between observers (P = .0965). There was a statistically significant variation between scan sets (P = .0036) attributed to minor vertical changes in the alignment of the test object between consecutive scan sets. CONCLUSION: The Artemis VHF digital US arc scanner obtained accurate, repeatable, and reproducible measurements of lateral dimensions of the size commonly found in the anterior segment.

Anterior Eye Segment↗

Direct residual stromal thickness measurement for assessing suitability for LASIK enhancement by Artemis 3D very high-frequency digital ultrasound arc scanning.

We present a patient scheduled for LASIK enhancement based on conventional residual stromal thickness (RST) prediction methods in whom direct measurement of the RST changed the management due to an unexpectedly low RST. The preoperative refraction was -6.00 -0.50 x 115 in the right eye and -6.00 -0.50 x 20 in the left eye. At 9 months, the refractions had regressed to -0.50 -0.50 x 150 and -0.75 -0.25 x 145, respectively. Predicted RST based on preoperative parameters was 283 microm in the right eye and 281 microm in the left eye, sufficient for the planned enhancement. Using the Artemis 3-dimensional very high-frequency digital ultrasound arc scanner, the minimum RST was directly measured as 277 microm in the right eye but only 212 microm in the left eye, which may have significantly increased the risk of iatrogenic ectasia yielding a predicted post-enhancement RST of 253 microm and 192 microm, respectively. The treatment plan was altered as a result of the thinner than predicted RST in the left eye; an enhancement was performed in the right eye only. A second Artemis examination after 22 months found the RST in the left eye to be stable.

Adult↗

Accuracy of the WASCA aberrometer refraction compared to manifest refraction in myopia.

PURPOSE: To evaluate the accuracy of myopic refraction by a single measurement using the Wavefront Supported Custom Ablation (WASCA) aberrometer (Carl Zeiss Meditec AG, Jena, Germany). METHODS: We retrospectively compared the refractive errors obtained by manifest refraction and wavefront refraction (WASCA) in 50 eyes of 25 consecutive myopic patients undergoing laser refractive surgery. The sphere ranged from -1.00 to -8.25 diopters (D) and cylinder from 0 to -3.75 D. WASCA measurements under cycloplegia were made and WASCA refractions calculated for a 6-mm analysis zone using the Seidel method within the WASCA. We used the manifest refraction as our best estimate of the true refractive error, therefore accuracy was defined as the difference between manifest refraction and that of the WASCA. Correlation coefficients and mean vector errors between manifest and WASCA refraction were calculated. RESULTS: High correlation was shown between manifest and WASCA refractions, with correlation coefficients (R2) of 0.97, 0.85, and 0.79 for M, J180, and J45, respectively. Mean power vector error (standard deviation) was 0.22 D (0.39), +0.03 D (0.21), and +0.03 D (0.13) for M, J180, and J45, respectively. Total dioptric power vector error was 0.43 D with 74% eyes within 0.50 D. CONCLUSIONS: When measuring normal myopic eyes, the concordance between manifest and WASCA refractions was found on average to be high; however, outlier measurements occurred.

Adult↗

Evaluating microkeratome efficacy by 3D corneal lamellar flap thickness accuracy and reproducibility using Artemis VHF digital ultrasound arc-scanning.

PURPOSE: To present a method that determines the efficacy of flap creation using a microkeratome. METHODS: Thirty-six eyes of 18 patients were included in the study, operated by two experienced surgeons using the Moria LSK-One microkeratome. Very high-frequency (VHF) digital ultrasound arc-scanning using Artemis technology was used to measure the Reinstein Flap Thickness Profile created by addition of the preoperative epithelial thickness profile to the postoperative stromal component of the flap. Descriptive statistics revealed central flap thickness accuracy and reproducibility. Univariate and multivariate regression analysis was used to determine correlations between central flap thickness and preoperative clinical parameters. Three-dimensional flap thickness maps demonstrated the mean, median, standard deviation, and range of thickness. RESULTS: Intended flap thickness was 160 microm. Mean central flap thickness was 161 microm in the right eye and 166 microm in the left eye. Central reproducibility (standard deviation of the mean) was 30.3 microm, with a range of 106 to 228 microm. Central flap thickness correlated to preoperative corneal thickness measured by VHF digital ultrasound but not by Orbscan. On qualitative analysis, no consistency among eyes was observed in the three-dimensional flap thickness map. Flaps were on average thinner in the center, but not in all cases. CONCLUSIONS: A systematic qualitative and quantitative statistical evaluation of microkeratome accuracy and reproducibility can be performed by measuring corneal flap thickness with arc-scanning VHF digital ultrasound.

Adult↗

Probability model of the inaccuracy of residual stromal thickness prediction to reduce the risk of ectasia after LASIK part I: quantifying individual risk.

PURPOSE: To measure the imprecision of microkeratome cuts, preoperative corneal pachymetry, and laser ablation depth and develop a statistical model to describe the probability of the residual stromal bed thickness (RST) after myopic LASIK being significantly thinner than predicted. METHODS: Preoperative corneal thickness, flap thickness, ablation depth, and RST were measured in 36 eyes by a prototype three-dimensional very high-frequency (VHF) 50 MHz digital ultrasound scanning device (<1.2 microm precision), precursor to the commercially available Artemis 2. All eyes had undergone LASIK with the Moria LSK-One microkeratome and the NIDEK EC-5000 excimer laser. Based on the statistically combined uncertainty (standard deviation) and bias (accuracy to intended value) of corneal thickness measurement, flap thickness, and ablation depth, a continuous probability function was devised describing the chance of obtaining an actual RST less than a specified "cut-off". The model was applied using the data collected from the cohort of eyes. The model was also applied using published flap thickness statistics on a series of microkeratomes. RESULTS: Precision (standard deviation) was 0.74 microm for VHF digital ultrasound measurement of pachymetry, 30.3 microm for Moria LSK-One flap thickness, and 11.2 microm for NIDEK EC-5000 ablation depth. Assuming negligible laser ablation depth bias, the model found the probability that the actual RST will be <200 pmicromgiven a target RST of 250 microm is 7.56% with the Moria LSK-One. The model applied to published flap statistics revealed a range of probabilities of leaving <200 microm given a target RST of 250 microm from <0.01% to 33.6%. CONCLUSIONS: The choice of microkeratome, laser, and pachymeter has a significant impact on the variation of the depth of keratectomy and thus on the risk of ectasia. This model together with high-precision microkeratomes, preoperative pachymetry, and knowledge of laser ablation precision would enable surgeons to determine the specific imprecision of RST prediction for individual LASIK cases and minimize the risk of ectasia.

Corneal Diseases↗

Probability model of the inaccuracy of residual stromal thickness prediction to reduce the risk of ectasia after LASIK part II: quantifying population risk.

PURPOSE: To derive a statistical model to estimate the rate of excessive keratectomy depth below a selected cut-off residual stromal thickness (RST) given a minimum target RST and specific Clinical Protocol; apply the model to estimate the RST below which ectasia appears likely to occur and back-calculate the safe minimum target RST that should be used given a specific Clinical Protocol. METHODS: Myopia and corneal thickness distribution were modeled for a population of 5212 eyes that underwent LASIK. The probability distribution of predicted target RST error (Part I) was used to calculate the rate of excessive keratectomy depth for this series. All treatments were performed using the same Clinical Protocol; one surgeon, Moria LSK-One microkeratome, NIDEK EC-5000 excimer laser, Orbscan pachymetry, and a minimum target RST of 250 microm--the Vancouver Clinical Protocol. The model estimated the RST below which ectasia appears likely to occur and back-calculated the safe minimum target RST. These values were recalculated for a series of microkeratomes using published flap thickness statistics as well as for the Clinical Protocol of one of the authors-the London Clinical Protocol. RESULTS: In the series of 5212 eyes, 6 (0.12%) cases of ectasia occurred. The model predicted an RST of 191 microm for ectasia to occur and that a minimum target RST of 329 microm would have reduced the -rate of ectasia to 1: 1,000,000 for the Vancouver Clinical Protocol. The model predicted that the choice of microkeratome varied the rate of ectasia between 0.01 and 11,623 eyes per million and the safe minimum target RST between 220 and 361 microm. The model predicted the rate of ectasia would have been 0.000003: 1,000,000 had the London Clinical Protocol been used for the Vancouver case series. CONCLUSIONS: There appears to be no universally safe minimum target RST to assess suitability for LASIK largely due to the disparity in accuracy and reproducibility of microkeratome flap thickness. This model may be used as a tool to evaluate the risk of ectasia due to excessive keratectomy depth and help determine the minimum target RST given a particular Clinical Protocol.

Corneal Diseases↗

Conservation of corneal tissue with wavefront-guided laser in situ keratomileusis.

PURPOSE: To determine whether corneal tissue can be conserved with wavefront-guided ablation compared to conventional surgery with a larger ablation zone for attempted prevention of glare and halo. SETTING: Department of Ophthalmology, Ilsan Paik Hospital, Inje University, Korea. METHODS: This prospective study was composed of 2 parts: First, 40 eyes of 20 patients were studied to determine whether a larger optical ablation could be beneficial in prevention of glare after conventional laser in situ keratomileusis (LASIK) surgery. One eye in each patient was treated with a 6.00 mm optical zone, and the other with a 6.25 mm optical zone. Second, 20 eyes of 10 patients with a higher-order root mean square (RMS) value of 0.3 or greater were evaluated to learn whether a wavefront-guided ablation could be as effective as a larger conventional optical ablation. One eye in each patient was treated by conventional LASIK surgery with a 6.25 mm optical zone, and the other eye was treated by wavefront-guided LASIK surgery with a 6.00 mm optical zone. All patients were analyzed with a WASCA analyzer (Carl Zeiss Meditec) preoperatively, and 1 month and 3 months after surgery. RESULTS: Higher-order aberrations including coma, spherical aberration, and higher-order RMS were statistically significantly increased after conventional surgery with both a 6.00 mm and 6.25 mm optical zone. High-order aberrations including comaer- and spherical aberration after conventional surgery with 6.25 mm zone were statistically significantly increased. However, coma and higher-order RMS did not show a statistically significant increase between pre-LASIK and post-LASIK in wavefront-ablated eyes with a 6.00 mm optical zone. CONCLUSION: Wavefront ablation showed less increase of coma and higher-order RMS regardless of a smaller optical zone. This finding might provide a clinical clue for an advantage of wavefront-guided ablation from the standpoint of corneal tissue conservation.

Adult↗

Orbscan global pachymetry: analysis of repeated measures.

PURPOSE: The Orbscan II is a hybrid slit-scanning and Placido disc corneal topographer capable mapping global pachymetry over a 10-mm corneal diameter. In this study, the repeatability of the Orbscan global pachymetry was determined. METHODS: Five consecutive Orbscan examinations were performed on one eye of 20 healthy volunteers by one examiner in one session. Mean, standard deviation, range of readings, and coefficient of variance were calculated for the central, thinnest point and global pachymetry. RESULTS: Orbscan repeatability for the central pachymetry was 3.62 microm (95% confidence interval [CI], 0.57-6.66) with a coefficient of variance of 0.67% (95% CI, 0.09-1.25) and intraclass correlation coefficient (ICC) of 0.978 (95% CI, 0.959-0.990). Thinnest point pachymetry had a repeatability of 4.25 microm (95% CI, 1.19-7.31) with a coefficient of variance of 0.80% (95% CI, 0.19-1.42) and ICC of 0.973 (95% CI, 0.950-0.988). Global pachymetry had a coefficient of variance <1.5% in the central 4 mm and <<2.5% across the entire cornea. Global pachymetry showed an area of greatest repeatability (<< +/- 5 microm) within a central 3.0-mm horizontal and 4.0-mm vertical diameter. DISCUSSION: Orbscan is capable of giving repeatable pachymetry readings that are comparable to the ultrasound pachymeter within the central and thinnest point of the cornea. There is a gradual loss of repeatability toward the peripheral cornea possibly as a result of a lack of overlapping data points.

Confidence Intervals↗

Optimized and wavefront guided corneal refractive surgery using the Carl Zeiss Meditec platform: the WASCA aberrometer, CRS-Master, and MEL80 excimer laser.

The Carl Zeiss Meditec platform for custom ablation incorporates a suite of technology integrating high-resolution wavefront aberrometry (WASCA), corneal surface shape data (TOSCA), energy stabilized excimer laser delivery (MEL80), and surgeon-controlled individualization of the ablation profile (CRS-Master). Together, these components deliver increasingly higher accuracy and sophistication in treatment planning for corneal refractive surgery.

Cornea↗

Phakic intraocular lenses.

An analytical review of the data available in the field of phakic intraocular lens implantation was conducted. Particular attention was paid to the more critical issues of intraocular lens sizing and safety guidelines. A comprehensive, competitive analysis of different implantation sites, intraocular lens model designs, and safety guidelines has been included. Specialized biometry techniques, such as very high frequency ultrasound and Scheimpflug imaging, have been reviewed, and a critical review of commercial claims regarding intraocular lens technologies has been included. Clinical studies of phakic intraocular lenses demonstrate increasing promise for the correction of refractive errors not amenable to mainstream excimer laser refractive surgery. The main issues currently revolve around adequate lens design (VHF ultrasound study suggests that custom-design and sizing may be the most effective and safest approach for every phakic IOL model), because these devices will be required to remain physiologically inert and anatomically compatible with internal ocular structures and relations for several decades. The possibility of safe removing or exchanging the IOL should remain a feasible option over time. It is of utmost importance that we continue to critically evaluate current encouraging short-term outcomes, which are being extrapolated to the longer term by ongoing high resolution imaging and monitoring of the anatomical and functional relations of implanted phakic IOLs.

Humans↗

Very high frequency ultrasound biometry of the anterior and posterior chamber diameter.

PURPOSE: To measure the largest diameter of the anterior chamber (AC) and posterior chamber (PC) dimension and its orientation and determine the relationship with the principal keratometric meridians. METHODS: Twenty-eight eyes of 14 subjects were scanned with high frequency (50 MHz) ultrasound in sequential meridional scan planes at 30 degrees increments. Observer identified angle and ciliary sulcus recess boundaries in each patient scan set were fit with an elliptical model to obtain the ellipse semi-major axis corresponding to the largest diameter and its meridional orientation. Anterior and posterior chamber diameters from raw data and model fit were compared using linear statistics. Circular statistics were used to compare the orientation of the largest diameter for raw ultrasound measurements, model estimations of largest diameter, and autorefractor determined keratometric axes. RESULTS: The mean model diameters were anterior chamber OD 12.07 mm (0.32 SD); anterior chamber OS 12.06 mm (0.36 SD); posterior chamber OD 12.35 mm (0.42 SD); posterior chamber OS 12.33 mm (0.43 SD). The general trend for orientation of the meridian of largest diameter was in the horizontal meridian. In over 35% of eyes the difference between AC or PC meridian and the flat keratometric axis was greater than 20 degrees. CONCLUSIONS: Accurate and reproducible anterior segment biometry depends on visualization of structures and minimization of eye and head movement error. The range and standard deviation of the diameter and orientation measures suggests anatomic variation is sufficient to require biometry for proper sizing and placement of intraocular devices that use angle or sulcus fixation.

Adult↗

VHF digital ultrasound three-dimensional scanning in the diagnosis of myopic regression after corneal refractive surgery.

PURPOSE: To perform VHF digital ultrasound scanning and analysis of a case of high-myopic undercorrection in an eye that had undergone multiple surgical interventions for the correction of an initial refraction of -12.00 diopters (D). METHODS: A 49-year-old woman was evaluated after undergoing three surgical interventions for correction of an initial refraction of -12.00 D in the left eye. Automated lamellar keratoplasty (ALK) was followed by arcuate keratotomy (for induced astigmatism) and surface photorefractive keratectomy (PRK). The residual ametropia on presentation was -6.75 -3.50 x 95 degrees. VHF digital ultrasound scanning and analysis was performed. RESULTS: On ultrasound, the ALK interface was clearly visible. Residual stromal thickness beneath the cap was at least 275 microm. The absence of Bowman's layer indicated the region of PRK. New stroma and nascent stromal layers were differentiated within the flap. Neo stromal deposition and central epithelial hyperplasia were determined to be responsible for the myopic shift, as opposed to biomechanical changes. CONCLUSIONS: In this case, refraction, slit-lamp examination, and topography were unable to provide a diagnosis for regression following multiple corneal refractive procedures. By providing layered anatomical mapping, VHF digital ultrasound scanning was able to exclude a diagnosis of ectasia and provide anatomical diagnostic information to explain the clinical observations.

Astigmatism↗

A new night vision disturbances parameter and contrast sensitivity as indicators of success in wavefront-guided enhancement.

PURPOSE: To determine the level of success of wavefront-guided repair of night vision disturbances after conventional (Munnerlyn) myopic LASIK using a new parameter to describe higher order aberrations, and to compare the improvements to matched myopic LASIK controls who were symptom-free. METHODS: We developed a single parameter metric to represent raw spherical aberration (RAWS) to functionally describe the cumulative spherical aberration for an eye over a range of physiological pupil sizes. To derive the RAWS parameter, spherical aberration is plotted over pupil analysis zones from 3000 to 6000 microm. The RAWS parameter (unit = microm2) is then equal to the area under the plot. Sixteen eyes treated for night vision disturbances by wavefront-guided repair were each compared to the mean of four matched control eyes (total 64 eyes) treated by aspheric myopic ablation and without night vision disturbances. Contrast sensitivity and RAWs parameter for spherical aberration were determined for each of the repair eyes and control eyes before and after surgery. RESULTS: Following wavefront-guided repair, 76% of eyes were subjectively reported to have night vision disturbances improved by at least 80%. The percentage of eyes within normal contrast range increased from 25% to 80% following wavefront-guided repair (P < .05). For the control eyes, LASIK increased RAWS by 126% (RAWS was 122 microm2 preoperatively and 276 microm2 postoperatively). For the night vision disturbances repair eye group, RAWS at presentation was 104% (563 microm2) above the respective postoperative RAWS control eyes. Following wavefront-guided repair, RAWS was decreased (P < .05) to only 49% (410 microm2) above the postoperative control group. CONCLUSIONS: The RAWS parameter enabled a single digit descriptor of overall higher order aberrations for an eye over the principal physiological pupil range. By comparing RAWS parameter changes in wavefront-guided repair eyes to matched postoperative asymptomatic eyes, we were able to determine the magnitude of the deficit in the symptomatic eyes and the relative efficacy of wavefront-guided repair.

Contrast Sensitivity↗

Valsalva-like retinopathy following hyperopic laser in situ keratomileusis.

A 50-year-old woman presented with unilateral acute loss of vision 15 hours after undergoing bilateral hyperopic laser in situ keratomileusis (LASIK). She denied "straining." Fluorescein angiography showed no retinal vascular abnormalities but demonstrated blocked fluorescence corresponding with subhyaloid, intraretinal, and subretinal hemorrhages seen clinically in the left eye. YAG laser vitreolysis was performed after noting posterior cortical vitreous thickening with a loculated subhyaloid hemorrhage. Best spectacle-corrected visual acuity was restored to 20/20 by the 2-month follow-up examination. Valsalva-like retinopathy, possibly the result of the rapid rise and fall of intraocular pressure during the microkeratome and suction ring operation, may occur following hyperopic LASIK surgery.

Diagnosis, Differential↗