Cluster analysis as a method for determining size ranges for spinal implants: disc lumbar replacement prosthesis dimensions from magnetic resonance images.

STUDY DESIGN: Statistical analysis of clinical radiologic data. OBJECTIVE: To develop an objective method for finding the number of sizes for a lumbar disc replacement. SUMMARY OF BACKGROUND DATA: Cluster analysis is a well-established technique for sorting observations into clusters so that the "similarity level" is maximal if they belong to the same cluster and minimal otherwise. METHODS: Magnetic resonance scans from 69 patients, with no abnormal discs, yielded 206 sagittal and transverse images of 206 discs (levels L3-L4-L5-S1). Anteroposterior and lateral dimensions were measured from vertebral margins on transverse images; disc heights were measured from sagittal images. Hierarchical cluster analysis was performed to determine the number of clusters followed by nonhierarchical (K-means) cluster analysis. Discriminant analysis was used to determine how well the clusters could be used to classify an observation. RESULTS: The most successful method of clustering the data involved the following parameters: anteroposterior dimension; lateral dimension (both were the mean of results from the superior and inferior margins of a vertebral body, measured on transverse images); and maximum disc height (from a midsagittal image). These were grouped into 7 clusters so that a discriminant analysis was capable of correctly classifying 97.1% of the observations. The mean and standard deviations for the parameter values in each cluster were determined. CONCLUSIONS: Cluster analysis has been successfully used to find the dimensions of the minimum number of prosthesis sizes required to replace L3-L4 to L5-S1 discs; the range of sizes would enable them to be used at higher lumbar levels in some patients.

Adult↗

Mechanical properties of calcium sulphate/hydroxyapatite cement.

Setting times, volume after setting, injectability and hardness (at 37 degrees C in contact with Ringer's solution) were determined for cements made of mixtures of calcium sulphate hemihydrate (CS) and hydroxyapatite (HA) with a range of compositions. The purpose of these experiments was to determine the behaviour of a mixture that could be used as an injectable cement for orthopaedic applications, including spinal fusion. A suitable mixture consisted of 60% CS and 40% HA by mass; a slurry was made by mixing solid (36 g) with water (15 cm(3)). The slurry had initial and final setting times of 5.7+/-1.3 min and 19.6+/-0.7 min (mean +/- standard deviation), respectively. The hardness of the cement did not systematically increase or decrease in the 72 h following the final setting time. The volume of the cement was 99.8+/-0.4% of the volume of the initial slurry, i.e. there was negligible shrinkage on setting. It was able to withstand a pressure of 7.3+/-1.2 MPa, applied by a hemispherical indenter before the onset of permanent damage, indicating adequate strength for spinal fusion.

Biocompatible Materials↗