PubMed Health⌕ Search

Biomedical subjects

Daniel B Kassel

Publications and source records attributed to Daniel B Kassel.

11 recordsLinked to original sources

Phosphopeptides enrichment using on-line two-dimensional strong cation exchange followed by reversed-phase liquid chromatography/mass spectrometry.

We have developed a method to isolate and enhance the detection of phosphopeptides using liquid chromatography (LC)/mass spectrometry on a tryptic-digested protein sample. The method uses an on-line two-dimensional chromatography approach that consists of strong cation exchange (SCX) followed by reversed-phase (RP) chromatography with mass spectrometric detection. At pH 2.6 or lower, tryptic phosphopeptides are not retained during the first-dimension SCX chromatography step. Thus the capture of these peptides in the flow-through by the second-dimension RP trap can dramatically reduce the complexity of the phosphopeptide chromatography, resulting in little or no suppression of the signal often caused by the coeluting nonphosphorylated peptides. The method provides higher phosphopeptide recovery and less nonspecific biding of acidic peptides than the commonly used enrichment methods, such as immobilized metal affinity chromatography. Since the widely adopted multidimensional LC strategy in shotgun proteomics uses a similar SCX-RP approach, the method can be adapted to detect and characterize phosphopeptides from a complex mixture in a single experiment. Limitations of the method are also discussed.

Amino Acid Sequence↗

Cell-based assay for screening 11beta-hydroxysteroid dehydrogenase inhibitors using liquid chromatography/tandem mass spectrometry detection.

Cortisol is an important glucocorticoid that regulates many physiological pathways by activating various intracellular receptors. The type 1 isozyme of 11beta-hydroxysteroid dehydrogenase (11beta-HSD1) functions in vivo predominantly as a reductase by converting cortisone into cortisol. A high-throughput liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed to screen for inhibitors of 11beta-HSD1 by monitoring cortisol and cortisone simultaneously. The injection cycle time can be as fast as 1 min/sample, making it amenable to the analysis of large numbers of the cell-assay samples in the screening of 11beta-HSD inhibitors. The reductase and dehydrogenase activities of 11beta-HSD1 are assessed separately.

11-beta-Hydroxysteroid Dehydrogenases↗

Substrate specificity and novel selective inhibitors of TNF-alpha converting enzyme (TACE) from two-dimensional substrate mapping.

We report a systematic analysis of the P1' and P2' substrate specificity of TNF-alpha converting enzyme (TACE) using a peptide library and a novel analytical method, and we use the substrate specificity information to design novel reverse hydroxamate inhibitors. Initial truncation studies, using the amino acid sequence around the cleavage site in precursor-TNF-alpha, showed that good turnover was obtained with the peptide DNP-LAQAVRSS-NH2. Based on this result, 1000 different peptide substrates of the form Biotin-LAQA-P1'-P2'-SSK(DNP)-NH2 were prepared, with 50 different natural and unnatural amino acids at P1' in combination with 20 different amino acids at P2'. The peptides were pooled, treated with purified microsomal TACE, and the reaction mixtures were passed over a streptavidin affinity column to remove unreacted substrate and the N-terminal biotinylated product. C-terminal cleavage products not binding to streptavidin were subjected to liquid chromatography/mass spectrometry analysis where individual products were identified and semiquantitated. 25 of the substrates were resynthesized as discrete peptides and assayed with recombinant TACE. The experiments show that recombinant TACE prefers lipophilic amino acids at the P1' position, such as phenylglycine, homophenylalanine, leucine and valine. At the P2' position, TACE can accommodate basic amino acids, such as arginine and lysine, as well as certain non-basic amino acids such as citrulline, methionine sulfoxide and threonine. These substrate preferences were used in the design of novel reverse hydroxamate TACE inhibitors with phenethyl and 5-methyl-thiophene-methyl side-chains at P1', and threonine and nitro-arginine at P2'.

ADAM Proteins↗

Automated high throughput ADME assays for metabolic stability and cytochrome P450 inhibition profiling of combinatorial libraries.

Early determinations of pharmaceutical properties can serve as predictors of a compound's likely development success. Our laboratory has implemented high throughput in vitro absorption, distribution, metabolism and excretion (ADME) assays which address absorption, metabolism, and physico-chemical properties in an effort to identify potential development liabilities early, thereby minimizing discovery to market attrition. In response to the throughput demands of parallel synthesis, we have incorporated a SAGIAN core robotics system for the determination of both metabolic stability in human liver microsomes (HLMs) and cytochrome P450 (CYP450) inhibition. This automated solution has led to an increase in capacity, throughput and reliability for both in vitro assays. The SAGIAN core robotics system integrates devices such as liquid handlers, plate hotels and incubators through the use of an ORCA robotic arm. The HLM stability assay utilizes a Multimek 96-channel pipettor for liquid handling. The incubation plates are transferred off-line for final semi-quantitative analysis using high throughput parallel LC/MS. The CYP inhibition method combines both liquid handlers and an integrated fluorescence plate reader to perform single concentration percent inhibition assays for 88 compounds. Cytochrome P450 inhibition is measured for both CYP3A4 and CYP2D6 isozymes. This system represents a fully integrated approach to high throughput ADME evaluation in support of drug discovery. The core system concept creates a plug-and-play approach, which combines a series of modular stations to build a robotic platform, which is flexible, upgradable, and easily reconfigured when assays change or are newly developed. The application of these strategies as a means of assessing metabolic stability and CYP inhibition of synthetic libraries is discussed.

Combinatorial Chemistry Techniques↗

Applications of high-throughput ADME in drug discovery.

Assessment of physicochemical and pharmacological properties is now conducted at very early stages of drug discovery for the purpose of accelerating the conversion of hits and leads into qualified development candidates. In particular, in vitro absorption, distribution, metabolism and elimination (ADME) assays and in vivo drug metabolism pharmacokinetic (DMPK) studies are being conducted throughout the discovery process, from hit generation through to lead optimization, with the goal of reducing the attrition rate of these potential drug candidates as they progress through development. Because the continuing trend in drug discovery has been to access ADME information earlier and earlier in the discovery process, the need has arisen within the analytical community to introduce faster and better analytical methods to enhance the 'developability' of drug leads. Strategies for streamlined ADME assessment of drug candidates in discovery and pre-clinical development are presented within.

Absorption↗

Structure of a c-kit product complex reveals the basis for kinase transactivation.

The c-Kit proto-oncogene is a receptor protein-tyrosine kinase associated with several highly malignant human cancers. Upon binding its ligand, stem cell factor (SCF), c-Kit forms an active dimer that autophosphorylates itself and activates a signaling cascade that induces cell growth. Disease-causing human mutations that activate SCF-independent constitutive expression of c-Kit are found in acute myelogenous leukemia, human mast cell disease, and gastrointestinal stromal tumors. We report on the phosphorylation state and crystal structure of a c-Kit product complex. The c-Kit structure is in a fully active form, with ordered kinase activation and phosphate-binding loops. These results provide key insights into the molecular basis for c-Kit kinase transactivation to assist in the design of new competitive inhibitors targeting activated mutant forms of c-Kit that are resistant to current chemotherapy regimes.

Chromatography, Liquid↗

Fragmentation of tunichrome Sp-1 is dominated by an unusual gas-phase intramolecular rearrangement.

Tunichrome Sp-1 is a modified pentapeptide from the ascidian Styela plicata, having the structure H-DOPA-DOPA-Gly-Pro-dcDeltaDOPA (where DOPA = 3,4-dihydroxyphenylalanine and dcDeltaDOPA = decarboxy-(E)-alpha,beta-dehydro-DOPA). The tandem mass spectrum of the peptide is dominated by a number of abundant fragment ions that involve a gas-phase rearrangement where the dcDeltaDOPA group becomes covalently attached to the N-terminus. The high degree of rearrangement in Sp-1 compared with a related octapeptide, plicatamide, allowed for detailed multiple mass spectrometric (MS(n)) (up to n = 6) experiments, and hence permitted a detailed assessment of the origin and routes to the formation of the various rearrangement ions. Analyses on both a triple-quadrupole and a quadrupole time-of-flight mass spectrometer were made to ascertain whether the gas-phase rearrangements observed for tunichrome Sp-1 were unique to an ion trap mass spectrometer (i.e. the hypothesis being that perhaps the extended trapping times were required to facilitate this unusual gas-phase rearrangement). Interestingly, analyses on both the triple-quadrupole and quadruple time-of-flight mass spectrometers revealed an identical phenomenon, with the rearrangement fragment ions present at approximately the same abundance as the non-rearranged a-, b- and y-type sequence ions. We suggest that the smaller size of tunichrome Sp-1 compared with plicatamide facilitates the transfer of the dcDeltaDOPA group in this gas-phase rearrangement. This rearrangement was not observed for peptide analogs of tunichrome Sp-1 that did not contain the dcDeltaDOPA at the C-terminus, confirming that the presence of dcDeltaDOPA is critical for the rearrangement.

Animals↗

High-throughput mass-directed parallel purification incorporating a multiplexed single quadrupole mass spectrometer.

We report on the development of a parallel HPLC/MS purification system incorporating an indexed (i.e., multiplexed) ion source. In the method described, each of the flow streams from a parallel array of HPLC columns is directed toward the multiplexed (MUX) ion source and sampled in a time-dependent, parallel manner. A visual basic application has been developed and monitors in real-time the extracted ion current from each sprayer channel. Mass-directed fraction collection is initiated into a parallel array of fraction collectors specific for each of the spray channels. In the first embodiment of this technique, we report on a four-column semipreparative parallel LC/MS system incorporating MUX detection. In this parallel LC/MS application (in which sample loads between 1 and 10 mg on-column are typically made), no cross talk was observed. Ion signals from each of the channels were found reproducible over 192 injections, with interchannel signal variations between 11 and 17%. The visual basic fraction collection application permits preset individual start collection and end collection thresholds for each channel, thereby compensating for the slight variation in signal between sprayers. By incorporating postfraction collector UV detection, we have been able to optimize the valve-triggering delay time with precut transfer tubing between the mass spectrometer and fraction collectors and achieve recoveries greater than 80%. Examples of the MUX-guided, mass-directed fraction purification of both standards and real library reaction mixtures are presented within.

Chromatography, High Pressure Liquid↗

Application of parallel liquid chromatography/mass spectrometry for high throughput microsomal stability screening of compound libraries.

Solution-phase and solid-phase parallel synthesis and high throughput screening have enabled biologically active and selective compounds to be identified at an unprecedented rate. The challenge has been to convert these hits into viable development candidates. To accelerate the conversion of these hits into lead development candidates, early assessment of the physicochemical and pharmacological properties of these compounds is being made. In particular, in vitro absorption, distribution, metabolism, and elimination (ADME) assays are being conducted at earlier and earlier stages of discovery with the goal of reducing the attrition rate of these potential drug candidates as they progress through development. In this report, we present an eight-channel parallel liquid chromatography/mass spectrometry (LC/MS) system in combination with custom Visual Basic and Applescript automated data processing applications for high throughput early ADME. The parallel LC/MS system was configured with one set of gradient LC pumps and an eight-channel multiple probe autosampler. The flow was split equivalently into eight streams before the multiple probe autosampler and recombined after the eight columns and just prior to the mass spectrometer ion source. The system was tested for column-to-column variation and for reproducibility over a 17 h period (approximately 500 injections per column). The variations in retention time and peak area were determined to be less than 2 and 10%, respectively, in both tests. The parallel LC/MS system described permits time-course microsomal incubations (t(o), t5, t15, t30) to be measured in triplicate and enables estimations of t 1/2 microsomal stability. The parallel LC/MS system is capable of analyzing up to 240 samples per hour and permits the complete profiling up to two microtiter plates of compounds per day (i.e., 176 test substrate compounds + sixteen controls).

Chromatography, High Pressure Liquid↗

Improvement of "hit-to-lead" optimization by integration of in vitro HTS experimental models for early determination of pharmacokinetic properties.

Development of predictive in vitro surrogate methods for traditional approaches assessing bioavailability and pharmacokinetics of lead compounds must be made to both keep pace with high-throughput (HT) lead identification and to mitigate the high costs associated with progression of compounds with poor chances of developmental success. Indeed opportunities for improvement still exist in the lead optimization phase versus the lead identification phase, where HT methodologies have been nearly optimized. Review of examples, limitations, and development of high-throughput microtiterplate-based assays for evaluating metabolic liabilities, such as in vitro radiometric and fluorometric assays for inhibition of cytochrome p450 (CYP) activity, determination of stability of a compound in liver microsomes, or cloned CYPs coupled to reconstituting systems are described. Parallel approaches to improve speed, resolution, sample preparation, as well as data analysis using LC/MS and LC/MS/MS approaches and technologies to assess compound integrity and biotransformation by automation and multiplexing are also discussed. Realization of the benefits in automation of cell-based models for determining drug permeability to predict drug absorption are still hampered by bottlenecks in analytical analysis of compounds. The implementation and limitations of surrogate physiochemical methods for passive adsorption such as immobilized artificial membranes (IAM) and parallel artificial membrane permeation assays (PAMPA), and compound solubility by laser nephelometry are reviewed as well. Additionally, data from a high-throughput 96-well equilibrium dialysis device, showing good correlation to classical methods, is presented. Finally, the impact of improvements in these downstream bottlenecks in lead optimization and preclinical drug discovery are discussed in this review.

Animals↗

Fluorous mixture synthesis of two libraries with hydantoin-, and benzodiazepinedione-fused heterocyclic scaffolds.

Diversity-oriented synthesis (DOS) and fluorous mixture synthesis (FMS) are two aspects of combinatorial chemistry. DOS generates library scaffolds with skeletal, substitution, and stereochemistry variations, whereas FMS is a highly efficient tool for library production. The combination of these two aspects in solution-phase synthesis of two novel heterocyclic compound libraries is presented in this paper. Mixtures of different fluorous amino acids undergo [3 + 2] cycloadditions followed by postcondensation reactions. The mixtures are then demixed by fluorous HPLC. Fluorous tags are removed by cyclization to afford hydantoin- and benzodiazepinedione-fused heterocyclic compounds as individual, pure, and structurally defined molecules. The application of MS-directed HPLC purification and parallel four-channel LC/MS analysis further increases the efficiency of FMS.

Benzodiazepines↗