PubMed Health⌕ Search

Biomedical subjects

Daniel C Fitzpatrick

Publications and source records attributed to Daniel C Fitzpatrick.

4 recordsLinked to original sources

Knee stability after articulated external fixation.

BACKGROUND: Articulated external fixation has been proposed as a method to protect ligament reconstructions while allowing aggressive and early postoperative rehabilitation after knee dislocation. However, the ability of these fixators to protect and stabilize the knee joint has not been clearly determined. HYPOTHESIS: Articulated external fixation can reduce anteroposterior translation in the cruciate-deficient knee and reduce cruciate ligament strain in cases of intact or reconstructed ligaments. STUDY DESIGN: Controlled laboratory study. METHODS: Knee stability was assessed by 3 standard clinical stability tests (Lachman, anterior drawer, and posterior drawer) on 7 human cadaveric lower extremities. Instrumented forces of 100 N were applied to the tibia to measure cruciate ligament forces and tibiofemoral displacement in intact and cruciate-deficient specimens with and without articulated external fixation to determine the degree to which a fixator can protect cruciate ligaments and stabilize the knee. Articulated external fixation was applied using monolateral and bilateral fixators to comparatively analyze the effectiveness of each construct. Statistical analysis was performed using 2-tailed, paired Student t tests. RESULTS: Application of the monolateral articulated external fixator to specimens with intact ligaments significantly reduced cruciate ligament forces by 1.0 N (P = .011), 1.7 N (P = .046), and 1.4 N (P = .009) for Lachman, anterior drawer, and posterior drawer tests, respectively. In the cruciate ligament-deficient knees, the application of a monolateral fixator significantly reduced tibiofemoral translation by 49%, 70%, and 46% for Lachman, anterior drawer, and posterior drawer tests, respectively. No significant differences between the monolateral and bilateral fixator frames, in terms of ligament protection and joint stabilization, were observed. CONCLUSION AND CLINICAL RELEVANCE: Articulated external fixation of the knee can reduce stress in the cruciate ligaments after multiligament reconstructions and can decrease anteroposterior translation in the cruciate-deficient knee.

Aged↗

Lag screws for hip fracture fixation: Evaluation of migration resistance under simulated walking.

Previous mechanical studies concerning cut-out of lag screws for pertrochanteric hip fractures have relied on static or dynamic uniaxial loading regimens to induce construct failure by varus collapse and superior cut-out. However, the hip is loaded in a multiplanar, dynamic manner during normal gait. We designed a hip implant performance simulator (HIPS) system to evaluate lag screw cut-out under multiplanar loading representative of normal gait. Five surrogate pertrochanteric fracture specimens with lag screw fixation were loaded up to 20,000 cycles using a biaxial rocking motion (BRM) gait simulation protocol. Another five specimens were loaded using a standard uniaxial loading protocol. The BRM loading group exhibited combined varus collapse (5.4+/-2.9 degrees ) and backward rotation (7.2+/-2.8 degrees ). The uniaxial loading group exhibited four times less varus collapse (1.4+/-1.1 degrees ) as compared to the BRM group, and only negligible rotation. For correlation of lag screw migration in surrogate specimens to that in native bone, six human cadaveric specimens were subjected to BRM loading. The degree of varus collapse (8.5+/-7.7 degrees ) and rotation (7.2+/-6.4 degrees ) in cadaveric specimens were comparable to that in surrogate specimens, with the surrogate specimens showing significantly less variability. The results demonstrate that accounting for clinically realistic multiplanar loading vectors significantly affects implant migration, and therefore should be considered when evaluating the fixation strength of hip screw implants.

Biomechanical Phenomena↗

Hinged external fixation of the knee: intrinsic factors influencing passive joint motion.

OBJECTIVE: To measure changes in knee kinematics after the application of articulated external fixators along a previously described knee flexion/extension axis and 16 specific "off-axis" fixator hinge configurations. DESIGN: Cadaver, biomechanical study. SETTING: Biomechanics laboratory. PARTICIPANTS: Nine fresh cadaver knee specimens. INTERVENTION: Each specimen was mounted on a custom-built frame that constrained the knee to move about a fixed flexion/extension axis. Passive knee motion was induced, and the resulting flexion moment was measured. Data were collected for the on-axis fixator position and 16 distinct rotational and translational off-axis positions. In addition, effects of tibial translation and rotation were investigated. MAIN OUTCOME: Range of motion (ROM) attainable within a moment envelope of +/-1 N-m and average energy required to impart movement. RESULTS: The average ROM for unconstrained knees was 122 degree. Constraining the knee to rotation around an on-axis aligned hinge significantly reduced the ROM by 35% to 79 degree. The 5-mm posterior translated hinge was the only alignment to show on average a slightly larger ROM (86 degree) than the on-axis hinge. All other hinge alignments showed decreased average ROM compared with the on-axis position. Tibiofemoral alignments significantly affected the obtainable ROM for the on-axis aligned hinge. CONCLUSION: It was not possible to replicate precisely the complex kinematics of the knee using a single axis fixator over the entire ROM. Using the axis of rotation previously defined in the literature, however, it was possible to obtain a limited ROM of the knee without placing excessive forces on the periarticular structures.

Aged↗

Kinematic and contact stress analysis of posterior malleolus fractures of the ankle.

OBJECTIVE: To determine if there are measurable dynamic contact stress aberrations and kinematic abnormalities (instability) that have not been observed in conventional static loading studies of posterior malleolar ankle fractures. DESIGN: Cadaveric fracture model. SETTING: Biomechanics laboratory. INTERVENTION: Seven fresh cadaveric specimens were fixed in an unconstrained testing apparatus and loaded to one body weight. The ankle was moved from 25 degrees of plantarflexion to 15 degrees of dorsiflexion. The model included the intact ankle and four fracture simulations (50% fracture without internal fixation, 2 mm gap and step malreductions, and anatomically fixed). MAIN OUTCOME MEASURE: Motion at the ankle was monitored with an electromagnetic tracking device, and intra-articular contact stresses were measured using a real-time stress sensor. RESULTS: There were no kinematic abnormalities suggestive of tibiotalar subluxation in any of the fracture simulations. There was no increase in peak contact stress in any of the fracture models compared with the unfractured model. However, there was a shift in the location of the contact stresses to a more anterior and medial location following the fracture. When summed over the range of motion, these areas of cartilage bore significantly higher cumulative contact stresses relative to the nonfracture situation. CONCLUSIONS: We found no talar subluxation and no increase in contact stresses near the articular incongruity, making it unlikely that these factors explain the increased incidence of arthrosis after trimalleolar fractures (OTA/AO classification 44 B3 fractures). Rather, we found that the joint remaining bears increased stress and that the center of stress shifts anteriorly, loading cartilage that normally sees little load.

Ankle Joint↗