Transthoracic impedance does not decrease with rapidly repeated countershocks in a swine cardiac arrest model.

STUDY PURPOSE: Successful defibrillation is dependent upon the delivery of adequate electrical current to the myocardium. One of the major determinant of current flow is transthoracic impedance. Prior work has suggested that impedance falls with repeated shocks during sinus rhythm. The purpose of this study was to evaluate changes in transthoracic impedance with repeated defibrillation shocks in an animal model of cardiac arrest due to ventricular fibrillation (VF). METHODS: VF was electrically induced in anesthetized swine. After 5 min of untreated VF, monophasic or biphasic waveform defibrillation was attempted using a standard sequence of 'stacked shocks' (200, 300, then 360 J, if necessary) administered via adhesive electrodes. If one of the first three shocks failed to convert VF, conventional CPR was initiated and defibrillation (360 J) attempted 1 min later. Strength-duration curves for delivered voltage and current were measured during each shock and transthoracic impedance calculated. Animals requiring a minimum of four shocks were selected for study inclusion. Impedance data from sequential shocks were analyzed using mixed linear models to account for the repeated-measures design and the variability of the initial impedance of individual animals. RESULTS: Thirteen animals (monophasic waveform, n=7, biphasic waveform, n=6) required at least four shocks to terminate VF (range 4-6). Transthoracic impedance did not change from the first shock in the 13 animals (46+/-8 Omega) to the fourth shock (46+/-9 Omega). In animals receiving more than four shocks, transthoracic impedance likewise did not change significantly from the first to the last shock, which terminated VF. The lack of a significant change in impedance was also observed when animals were analyzed according to defibrillation waveform. CONCLUSION: Transthoracic impedance does not change significantly with repeated shocks in a VF cardiac arrest model. This is likely due to the lack of reactive skin and soft tissue hyperemia and edema observed in non-arrest models.

Animals↗

Left ventricular function after monophasic and biphasic waveform defibrillation: the impact of cardiopulmonary resuscitation time on contractile indices.

UNLABELLED: Previous work has suggested that low-energy biphasic waveform defibrillation (BWD) is followed by less post-resuscitation left ventricular (LV) dysfunction when compared with higher-energy monophasic waveform defibrillation (MWD). To the best of the authors' knowledge, the effect of cardiopulmonary resuscitation (CPR) duration and total ischemia time on LV function after countershock, controlling for waveform type, has not been evaluated. OBJECTIVE: To determine the effect of CPR duration on LV function after MWD and BWD. METHODS: VF was electrically induced in anesthetized and instrumented swine. After 5 minutes of VF, the animals were randomized to MWD (n = 22) or one of two BWDs (n = 46). If countershock terminated VF but was followed by a nonperfusing rhythm, conventional manual CPR without drug therapy was performed until restoration of spontaneous circulation (ROSC), defined as a systolic arterial pressure >60 mm Hg for 10 minutes without vasopressor support. Systolic LV pressure (LVP), LV dP/dt (first derivative of pressure measured over time), and cardiac output (CO) were measured at intervals for 60 minutes postresuscitation. CPR times (times to ROSC) and hemodynamic variables for the three groups were compared. Multivariable linear regression was performed to assess the contribution of defibrillation waveform, total joules, and CPR time on LVP, LV dP/dt, and CO at 15, 30, and 60 minutes postresuscitation. RESULTS: When analyzed as groups, significant differences in median number of shocks to terminate VF, total joules, or CPR time were not observed between waveform groups. Regression analysis demonstrated that increasing CPR time was associated with a significant effect on indices of LV function at 15 and 30 minutes postresuscitation. Global LV function was not influenced by waveform type or total joules. CONCLUSIONS: Adjustment for CPR time, a determinant of total myocardial ischemia time, is necessary when defibrillation waveforms are compared for their effect on postresuscitation cardiac function and short-term outcome.

Animals↗