PubMed Health⌕ Search

Biomedical subjects

Daniel H Farkas

Publications and source records attributed to Daniel H Farkas.

7 recordsLinked to original sources

Detection of the JAK2(V617F) mutation in myeloproliferative disorders by melting curve analysis using the LightCycler system.

CONTEXT: A specific mutation, JAK2(V617F), was recently recognized as having diagnostic value for myeloproliferative disorders. No practical assay is currently available for routine use in a clinical laboratory. OBJECTIVE: We report the development of a real-time polymerase chain reaction melting curve analysis assay that is appropriate for molecular diagnostics testing. DESIGN: Specific primers and fluorescence resonance energy transfer probes were designed, and patients with a previously diagnosed myeloproliferative disorder, de novo acute myeloid leukemia, or reactive condition were selected. The DNA was extracted from fresh and archived peripheral blood and bone marrow specimens, and real-time polymerase chain reaction melting curve analysis was performed on the LightCycler platform (Roche Applied Science, Indianapolis, Ind). RESULTS: The JAK2 region was successfully amplified, and wild-type amplicons were reproducibly discriminated from JAK2(V617F) amplicons. Titration studies using homozygous wild-type and mutant cell lines showed the relative areas under a melting curve were proportional to allele proportion, and the assay reliably detected one mutant in 20 total cells. JAK2(V617F) was identified in patients previously diagnosed with a myeloproliferative disorder or acute myeloid leukemia transformed from myeloproliferative disorder, whereas a wild-type genotype was identified in patients with reactive conditions or de novo acute myeloid leukemia. CONCLUSIONS: These findings demonstrate the suitability of this assay for identifying JAK2(V617F) in a clinical laboratory setting. Furthermore, the semiquantitative detection of JAK2(V617F) in archived specimens provides a new tool for studying the prognostic significance of this mutation.

Bone Marrow Cells↗

Genetically characterized positive control cell lines derived from residual clinical blood samples.

BACKGROUND: Positive control materials for clinical diagnostic molecular genetic testing are in critically short supply. High-quality DNA that closely resembles DNA isolated from patient specimens can be obtained from Epstein-Barr virus (EBV)-transformed peripheral blood lymphocyte cell lines. Here we report the development of a process to (a) recover residual blood samples with clinically important mutations detected during routine medical care, (b) select samples likely to provide viable lymphocytes for EBV transformation, (c) establish stable cell lines and confirm the reported mutation(s), and (d) validate the cell lines for use as positive controls in clinical molecular genetic testing applications. METHODS: A network of 32 genetic testing laboratories was established to obtain anonymous, residual clinical samples for transformation and to validate resulting cell lines for use as positive controls. Three panel meetings with experts in molecular genetic testing were held to evaluate results and formulate a process that could function in the context of current common practices in molecular diagnostic testing. RESULTS: Thirteen laboratories submitted a total of 113 residual clinical blood samples with mutations for 14 genetic disorders. Forty-one EBV-transformed cell lines were established. Thirty-five individual point and deletion mutations were shown to be stable after 20 population doublings in culture. Thirty-three cell lines were characterized for specific mutations and validated for use as positive controls in clinical diagnostic applications. CONCLUSIONS: A process for producing and validating positive control cell lines from residual clinical blood samples has been developed. Sustainable implementation of the process could help alleviate the current shortage of positive control materials.

Blood Specimen Collection↗

Developing a sustainable process to provide quality control materials for genetic testing.

PURPOSE: To provide a summary of the outcomes of two working conferences organized by the Centers for Disease Control and Prevention (CDC), to develop recommendations for practical, sustainable mechanisms to make quality control (QC) materials available to the genetic testing community. METHODS: Participants were selected to include experts in genetic testing and molecular diagnostics from professional organizations, government agencies, industry, laboratories, academic institutions, cell repositories, and proficiency testing (PT)/external Quality Assessment (EQA) programs. Current efforts to develop QC materials for genetic tests were reviewed; key issues and areas of need were identified; and workgroups were formed to address each area of need and to formulate recommendations and next steps. RESULTS: Recommendations were developed toward establishing a sustainable process to improve the availability of appropriate QC materials for genetic testing, with an emphasis on molecular genetic testing as an initial step. CONCLUSIONS: Improving the availability of appropriate QC materials is of critical importance for assuring the quality of genetic testing, enhancing performance evaluation and PT/EQA programs, and facilitating new test development. To meet the needs of the rapidly expanding capacity of genetic testing in clinical and public health settings, a comprehensive, coordinated program should be developed. A Genetic Testing Quality Control Materials Program has therefore been established by CDC in March 2005 to serve these needs.

Centers for Disease Control and Prevention, U.S.↗

Bioelectronic DNA detection of human papillomaviruses using eSensor: a model system for detection of multiple pathogens.

BACKGROUND: We used human papillomaviruses (HPV) as a model system to evaluate the utility of a nucleic acid, hybridization-based bioelectronic DNA detection platform (eSensor) in identifying multiple pathogens. METHODS: Two chips were spotted with capture probes consisting of DNA oligonucleotide sequences specific for HPV types. Electrically conductive signal probes were synthesized to be complementary to a distinct region of the amplified HPV target DNA. A portion of the HPV L1 region that was amplified by using consensus primers served as target DNA. The amplified target was mixed with a cocktail of signal probes and added to a cartridge containing a DNA chip to allow for hybridization with complementary capture probes. RESULTS: Two bioelectric chips were designed and successfully detected 86% of the HPV types contained in clinical samples. CONCLUSIONS: This model system demonstrates the potential of the eSensor platform for rapid and integrated detection of multiple pathogens.

Biosensing Techniques↗

Bioelectronic sensor technology for detection of cystic fibrosis and hereditary hemochromatosis mutations.

CONTEXT: Bioelectronic sensors, which combine microchip and biological components, are an emerging technology in clinical diagnostic testing. An electronic detection platform using DNA biochip technology (eSensor) is under development for molecular diagnostic applications. Owing to the novelty of these devices, demonstrations of their successful use in practical diagnostic applications are limited. OBJECTIVE: To assess the performance of the eSensor bioelectronic method in the validation of 6 Epstein-Barr virus-transformed blood lymphocyte cell lines with clinically important mutations for use as sources of genetic material for positive controls in clinical molecular genetic testing. Two cell lines carry mutations in the CFTR gene (cystic fibrosis), and 4 carry mutations in the HFE gene (hereditary hemochromatosis). DESIGN: Samples from each cell line were sent for genotype determination to 6 different molecular genetic testing facilities, including the laboratory developing the DNA biochips. In addition to the bioelectronic method, at least 3 different molecular diagnostic methods were used in the analysis of each cell line. Detailed data were collected from the DNA biochip output, and the genetic results were compared with those obtained using the more established methods. RESULTS: We report the successful use of 2 applications of the bioelectronic platform, one for detection of CFTR mutations and the other for detection of HFE mutations. In all cases, the results obtained with the DNA biochip were in concordance with those reported for the other methods. Electronic signal output from the DNA biochips clearly differentiated between mutated and wild-type alleles. This is the first report of the use of the cystic fibrosis detection platform. CONCLUSIONS: Bioelectronic sensors for the detection of disease-causing mutations performed well when used in a "real-life" situation, in this case, a validation study of positive control blood lymphocyte cell lines with mutations of public health importance. This study illustrates the practical potential of emerging bioelectronic DNA detection technologies for use in current molecular diagnostic applications.

Base Sequence↗