Recumbent stepping has similar but simpler neural control compared to walking.

The purpose of this study was to compare muscle activation patterns and kinematics during recumbent stepping and walking to determine if recumbent stepping has a similar motor pattern as walking. We measured joint kinematics and electromyography in ten neurologically intact humans walking on a treadmill at 0 and 50% body weight support (BWS), and recumbent stepping using a commercially available exercise machine. Cross correlation of upper and lower limb electromyography patterns between conditions revealed high correlations for most muscles. A principal component analysis revealed that the first factor accounted for more muscle activation signal content during recumbent stepping (81%) than during walking (70%). This indicates that the motor pattern during walking is more complex than during stepping. Cross correlation analysis found a high correlation between factors for recumbent stepping and walking (R = 0.54), though not as high as the correlation between factors for walking at 0% BWS and walking at 50% BWS (R = 0.68). There were substantial differences in joint kinematics between walking and recumbent stepping, most notably in hip, elbow, and shoulder motions. These results suggest that although the two tasks have different kinematic patterns, recumbent stepping relies on similar neural networks as walking. Individuals with neurological impairments may be able to improve walking ability from recumbent stepping practice given similarities in neural control between the two tasks.

Adolescent↗

Symmetry-based resistance as a novel means of lower limb rehabilitation.

Robotic devices hold much promise for use as rehabilitation aids but their success depends on identifying effective strategies for controlling human-robot interaction forces. We developed a robotic device to test a novel method of controlling interaction forces with the intent of improving force symmetry in the limbs. Users perform lower limb extensions against a computer-controlled resistive load. The control software increases resistance above baseline in proportion to lower limb force asymmetry (balance between left and right limb forces). As a preliminary trial to test the device and controller, we conducted two experiments on neurologically intact subjects. In experiment 1, one group of subjects received symmetry-based resistance while performing lower limb extensions (n=10). A control group performed the same movements with constant resistance (n=10). The symmetry-based resistance group improved lower limb symmetry during training (ANOVA, p<0.05), whereas the control subjects did not. In experiment 2, subjects (n=10) successfully used symmetry-based resistance to alter their lower limb force production towards a target asymmetry (ANOVA, p<0.05). These studies suggest that symmetry-based resistance may hold rehabilitation benefits after orthopedic or neurological injury. Specifically, performing strength training therapy with this controller may allow hemiparetic individuals to focus better on increasing strength and neuromuscular recruitment in their paretic limb while experiencing symmetric limb forces.

Adult↗

The effects of powered ankle-foot orthoses on joint kinematics and muscle activation during walking in individuals with incomplete spinal cord injury.

BACKGROUND: Powered lower limb orthoses could reduce therapist labor during gait rehabilitation after neurological injury. However, it is not clear how patients respond to powered assistance during stepping. Patients might allow the orthoses to drive the movement pattern and reduce their muscle activation. The goal of this study was to test the effects of robotic assistance in subjects with incomplete spinal cord injury using pneumatically powered ankle-foot orthoses. METHODS: Five individuals with chronic incomplete spinal cord injury (ASIA C-D) participated in the study. Each subject was fitted with bilateral ankle-foot orthoses equipped with artificial pneumatic muscles to power ankle plantar flexion. Subjects walked on a treadmill with partial bodyweight support at four speeds (0.36, 0.54, 0.72 and 0.89 m/s) under three conditions: without wearing orthoses, wearing orthoses unpowered (passively), and wearing orthoses activated under pushbutton control by a physical therapist. Subjects also attempted a fourth condition wearing orthoses activated under pushbutton control by them. We measured joint angles, electromyography, and orthoses torque assistance. RESULTS: A therapist quickly learned to activate the artificial pneumatic muscles using the pushbuttons with the appropriate amplitude and timing. The powered orthoses provided approximately 50% of peak ankle torque. Ankle angle at stance push-off increased when subjects walked with powered orthoses versus when they walked with passive-orthoses (ANOVA, p < 0.05). Ankle muscle activation amplitudes were similar for powered and passive-orthoses conditions except for the soleus (approximately 13% lower for powered condition; p < 0.05). Two of the five subjects were able to control the orthoses themselves using the pushbuttons. The other three subjects found it too difficult to coordinate pushbutton timing. Orthoses assistance and maximum ankle angle at push-off were smaller when the subject controlled the orthoses compared to when the therapist-controlled the orthoses (p < 0.05). Muscle activation amplitudes were similar between the two powered conditions except for tibialis anterior (approximately 31% lower for therapist-controlled; p < 0.05). CONCLUSION: Mechanical assistance from powered ankle-foot orthoses improved ankle push-off kinematics without substantially reducing muscle activation during walking in subjects with incomplete spinal cord injury. These results suggest that robotic plantar flexion assistance could be used during gait rehabilitation without promoting patient passivity.

Journal Article↗

Moving the arms to activate the legs.

Recent studies on neurologically intact individuals and individuals with spinal cord injury indicate that rhythmic upper limb muscle activation has an excitatory effect on lower limb muscle activation during locomotor-like tasks. This finding suggests that gait rehabilitation therapy after neurological injury should incorporate simultaneous upper limb and lower limb rhythmic exercise to take advantage of neural coupling.

Arm↗

Neuromechanical adaptation to hopping with an elastic ankle-foot orthosis.

When humans hop or run on different surfaces, they adjust their effective leg stiffness to offset changes in surface stiffness. As a result, the overall stiffness of the leg-surface series combination remains independent of surface stiffness. The purpose of this study was to determine whether humans make a similar adjustment when springs are placed in parallel with the leg via a lower limb orthosis. We studied seven human subjects hopping in place on one leg while wearing an ankle-foot orthosis. We used an ankle-foot orthosis because the ankle joint is primarily responsible for leg stiffness during hopping. A spring was added to the ankle-foot orthosis so that it increased orthosis stiffness by providing plantar flexor torque during ankle dorsiflexion. We hypothesized that subjects would decrease their biological ankle stiffness when the spring was added to the orthosis, keeping total ankle stiffness constant. We collected kinematic, kinetic, and electromyographic data during hopping with and without the spring on the orthosis. We found that total ankle stiffness and leg stiffness did not change across the two orthosis conditions (ANOVA, P > 0.05). This was possible because subjects decreased their biological ankle stiffness to offset the orthosis spring stiffness (P < 0.0001). The reduction in biological ankle stiffness was accompanied by decreases in soleus, medial gastrocnemius, and lateral gastrocnemius muscle activation (P < 0.0002). These results suggest that an elastic exoskeleton might improve human running performance by reducing muscle recruitment.

Adaptation, Physiological↗

An improved powered ankle-foot orthosis using proportional myoelectric control.

We constructed a powered ankle-foot orthosis for human walking with a novel myoelectric controller. The orthosis included a carbon fiber and polypropylene shell, a metal hinge joint, and two artificial pneumatic muscles. Soleus electromyography (EMG) activated the artificial plantar flexor and inhibited the artificial dorsiflexor. Tibialis anterior EMG activated the artificial dorsiflexor. We collected kinematic, kinetic, and electromyographic data for a naive healthy subject walking with the orthosis. The current design improves upon a previous prototype by being easier to don and doff and simpler to use. The novel controller allows naive wearers to quickly adapt to the orthosis without artificial muscle co-contraction. The orthosis may be helpful in studying human walking biomechanics and assisting patients during gait rehabilitation after neurological injury.

Adult↗

Mechanical performance of artificial pneumatic muscles to power an ankle-foot orthosis.

We developed a powered ankle-foot orthosis that uses artificial pneumatic muscles to produce active plantar flexor torque. The purpose of this study was to quantify the mechanical performance of the orthosis during human walking. Three subjects walked at a range of speeds wearing ankle-foot orthoses with either one or two artificial muscles working in parallel. The orthosis produced similar total peak plantar flexor torque and network across speeds independent of the number of muscles used. The orthosis generated approximately 57% of the peak ankle plantar flexor torque during stance and performed approximately 70% of the positive plantar flexor work done during normal walking. Artificial muscle bandwidth and force-length properties were the two primary factors limiting torque production. The lack of peak force and work differences between single and double muscle conditions can be explained by force-length properties. Subjects altered their ankle kinematics between conditions resulting in changes in artificial muscle length. In the double muscle condition greater plantar flexion yielded shorter artificial muscles lengths and decreased muscle forces. This finding emphasizes the importance of human testing in the design and development of robotic exoskeleton devices for assisting human movement. The results of this study outline the mechanical performance limitations of an ankle-foot orthosis powered by artificial pneumatic muscles. This orthosis could be valuable for gait rehabilitation and for studies investigating neuromechanical control of human walking.

Adult↗

An ankle-foot orthosis powered by artificial pneumatic muscles.

We developed a pneumatically powered orthosis for the human ankle joint. The orthosis consisted of a carbon fiber shell, hinge joint, and two artificial pneumatic muscles. One artificial pneumatic muscle provided plantar flexion torque and the second one provided dorsiflexion torque. Computer software adjusted air pressure in each artificial muscle independently so that artificial muscle force was proportional to rectified low-pass-filtered electromyography (EMG) amplitude (i.e., proportional myoelectric control). Tibialis anterior EMG activated the artificial dorsiflexor and soleus EMG activated the artificial plantar flexor. We collected joint kinematic and artificial muscle force data as one healthy participant walked on a treadmill with the orthosis. Peak plantar flexor torque provided by the orthosis was 70 Nm, and peak dorsiflexor torque provided by the orthosis was 38 Nm. The orthosis could be useful for basic science studies on human locomotion or possibly for gait rehabilitation after neurological injury.

Adult↗

The effect of movement frequency on interlimb coupling during recumbent stepping.

During passive lower limb movement, active use of the upper limbs increases unintentional lower limb muscle activation. We hypothesized that faster movement frequencies would amplify lower limb muscle activation during upper limb exertion but would not affect lower limb muscle activation when the upper limbs were relaxed. We studied 10 healthy participants exercising on a recumbent stepping machine that mechanically coupled the four limbs via handles and pedals. Participants exercised at four frequencies (30, 60, 90, 120 steps/min) under four conditions of active and passive movement. Self-driven lower limb motion resulted in greater muscle activation compared to externally driven lower limb motion. Muscle activation amplitude increased with frequency for all conditions except for externally driven stepping. These results indicate that fast upper limb movement facilitates neuromuscular recruitment of lower limb muscles during stepping tasks. If a similar effect occurs in neurologically impaired individuals during active stepping, self-assisted exercise might enhance neuromuscular recruitment during rehabilitation.

Adult↗

Powered lower limb orthoses for gait rehabilitation.

Bodyweight supported treadmill training has become a prominent gait rehabilitation method in leading rehabilitation centers. This type of locomotor training has many functional benefits but the labor costs are considerable. To reduce therapist effort, several groups have developed large robotic devices for assisting treadmill stepping. A complementary approach that has not been adequately explored is to use powered lower limb orthoses for locomotor training. Recent advances in robotic technology have made lightweight powered orthoses feasible and practical. An advantage to using powered orthoses as rehabilitation aids is they allow practice starting, turning, stopping, and avoiding obstacles during overground walking.

Journal Article↗

Proportional myoelectric control of a virtual object to investigate human efferent control.

We used proportional myoelectric control of a one-dimensional virtual object to investigate differences in efferent control between the proximal and distal muscles of the upper limbs. Eleven subjects placed one of their upper limbs in a brace that restricted movement while we recorded electromyography (EMG) signals from elbow flexors/extensors or wrist flexors/extensors during isometric contractions. By activating their muscles, subjects applied virtual forces to a virtual object using a real-time computer interface. The magnitudes of these forces were proportional to EMG amplitudes. Subjects used this proportional EMG control to move the virtual object through two tracking tasks, one with a static target and one with a moving target (i.show $132#e., a sine wave). We hypothesized that subjects would have better control over the virtual object using their distal muscles rather than using their proximal muscles because humans typically use more distal joints to perform fine motor tasks. The results indicated that there was no difference in subjects' ability to control virtual object movements when using either upper arm muscles or forearm muscles. These results suggest that differences in control accuracy between elbow joint movements and wrist joint movements are more likely to be a result of motor practice, proprioceptive feedback or joint mechanics rather than inherent differences in efferent control.

Adult↗

Neural coupling between upper and lower limbs during recumbent stepping.

During gait rehabilitation, therapists or robotic devices often supply physical assistance to a patient's lower limbs to aid stepping. The expensive equipment and intensive manual labor required for these therapies limit their availability to patients. One alternative solution is to design devices where patients could use their upper limbs to provide physical assistance to their lower limbs (i.e., self-assistance). To explore potential neural effects of coupling upper and lower limbs, we investigated neuromuscular recruitment during self-driven and externally driven lower limb motion. Healthy subjects exercised on a recumbent stepper using different combinations of upper and lower limb exertions. The recumbent stepper mechanically coupled the upper and lower limbs, allowing users to drive the stepping motion with upper and/or lower limbs. We instructed subjects to step with 1) active upper and lower limbs at an easy resistance level (active arms and legs); 2) active upper limbs and relaxed lower limbs at easy, medium, and hard resistance levels (self-driven); and 3) relaxed upper and lower limbs while another person drove the stepping motion (externally driven). We recorded surface electromyography (EMG) from six lower limb muscles. Self-driven EMG amplitudes were always higher than externally driven EMG amplitudes (P < 0.05). As resistance and upper limb exertion increased, self-driven EMG amplitudes also increased. EMG bursts during self-driven and active arms and legs stepping occurred at similar times. These results indicate that active upper limb movement increases neuromuscular activation of the lower limbs during cyclic stepping motions. Neurologically impaired humans that actively engage their upper limbs during gait rehabilitation may increase neuromuscular activation and enhance activity-dependent plasticity.

Adult↗