Daniel P Nicolella

Publications and source records attributed to Daniel P Nicolella.

4 recordsLinked to original sources

Tissue strain amplification at the osteocyte lacuna: a microstructural finite element analysis.

A parametric finite element model of an osteocyte lacuna was developed to predict the microstructural response of the lacuna to imposed macroscopic strains. The model is composed of an osteocyte lacuna, a region of perilacunar tissue, canaliculi, and the surrounding bone tissue. A total of 45 different simulations were modeled with varying canalicular diameters, perilacunar tissue material moduli, and perilacunar tissue thicknesses. Maximum strain increased with a decrease in perilacunar tissue modulus and decreased with an increase in perilacunar tissue modulus, regardless of the thickness of the perilacunar region. An increase in the predicted maximum strain was observed with an increase in canalicular diameter from 0.362 to 0.421 microm. In response to the macroscopic application of strain, canalicular diameters increased 0.8% to over 1.0% depending on the perilacunar tissue modulus. Strain magnification factors of over 3 were predicted. However, varying the size of the perilacunar tissue region had no effect on the predicted perilacunar tissue strain. These results indicate that the application of average macroscopic strains similar to strain levels measured in vivo can result in significantly greater perilacunar tissue strains and canaliculi deformations. A decrease in the perilacunar tissue modulus amplifies the perilacunar tissue strain and canaliculi deformation while an increase in the local perilacunar tissue modulus attenuates this effect.

Adaptation, Physiological↗

Osteocyte lacunae tissue strain in cortical bone.

Current theories suggest that bone modeling and remodeling are controlled at the cellular level through signals mediated by osteocytes. However, the specific signals to which bone cells respond are still unknown. Two primary theories are: (1) osteocytes are stimulated via the mechanical deformation of the perilacunar bone matrix and (2) osteocytes are stimulated via fluid flow generated shear stresses acting on osteocyte cell processes within canaliculi. Recently, much focus has been placed on fluid flow theories since in vitro experiments have shown that bone cells are more responsive to analytically estimated levels of fluid shear stress than to direct mechanical stretching using macroscopic strain levels measured on bone in vivo. However, due to the complex microstructural organization of bone, local perilacunar bone tissue strains potentially acting on osteocytes cannot be reliably estimated from macroscopic bone strain measurements. Thus, the objective of this study was to quantify local perilacunar bone matrix strains due to macroscopically applied bone strains similar in magnitude to those that occur in vivo. Using a digital image correlation strain measurement technique, experimentally measured bone matrix strains around osteocyte lacunae resulting from macroscopic strains of approximately 2000 microstrain are significantly greater than macroscopic strain on average and can reach peak levels of over 30,000 microstrain locally. Average strain concentration factors ranged from 1.1 to 3.8, which is consistent with analytical and numerical estimates. This information should lead to a better understanding of how bone cells are affected by whole bone functional loading.

Animals↗

The effect of three-dimensional shape optimization on the probabilistic response of a cemented femoral hip prosthesis.

Probabilistic analyses allow the effect of uncertainty in system parameters on predicted model performance measures to be determined. Furthermore, using performance functions to describe a failure event, the probability of failure can be quantified. The effect of three-dimensional prosthesis shape optimization on the probabilistic response and failure probability of a cemented hip prosthesis system is investigated. Random variables include joint and muscle loading, cortical and cancellous bone and PMMA bone cement elastic properties, and strength parameters describing failure of the bone cement and the prosthesis-bone cement interface. Several performance functions describing the bone cement and prosthesis-cement interface are used to compute the probability of failure. When evaluated deterministically, most performance functions indicated a safe design, with the exception of interface tensile failure. However, when evaluated probabilistically, finite probabilities of failure were computed, some significant. The most likely mode of failure before shape optimization was prosthesis-bone cement interface tensile failure with a predicted probability of failure of 97.9%. Deterministic prosthesis shape optimization reduced the probability of failure for all performance functions and reduced prosthesis-bone cement interface tensile failure by 31.7%. Probability sensitivity factors indicate that the uncertainty in the joint loading, cement strength, and implant-cement interface strength have the greatest effect on the computed probability of failure. Implant shape optimization results in a more robust implant design that is less sensitive to uncertainties in joint loading, which cannot be easily controlled, and more sensitive to cement and interface properties, which are easier to modify.

Cementation↗

Measurement of microstructural strain in cortical bone.

It is well known that mechanical factors affect bone remodeling such that increased mechanical demand results in net bone formation, whereas decreased demand results in net bone resorption. Current theories suggest that bone modeling and remodeling is controlled at the cellular level through signals mediated by osteocytes. The objective of this study was to investigate how macroscopically applied bone strains similar in magnitude to those that occur in vivo are manifest at the microscopic level in the bone matrix. Using a digital image correlation strain measurement technique, experimentally determined bone matrix strains around osteocyte lacuna resulting from macroscopic strains of approximately 2,000 microstrain (0.2%) reach levels of over 30,000 microstrain (3%) over fifteen times greater than the applied macroscopic strain. Strain patterns were highly heterogeneous and in some locations similar to observed microdamage around osteocyte lacuna indicating the resulting strains may represent the precursors to microdamage. This information may lead to a better understanding of how bone cells are affected by whole bone functional loading.

Animals↗