PubMed Health⌕ Search

Biomedical subjects

Daniel Rodríguez

Publications and source records attributed to Daniel Rodríguez.

3 recordsLinked to original sources

Effects of estradiol on phenylephrine contractility associated with intracellular calcium release in rat aorta.

The ability of estradiol to affect phenylephrine-induced contraction and the subsequent increase in resting tone, associated with capacitative Ca(2+) entry across the plasma membrane, was evaluated in rat aortic rings incubated in Ca(2+)-free solution. The incubation with estradiol (1-100 nM, 5 min) inhibited both the phenylephrine-induced contraction and the IRT. Neither cycloheximide (1 microM; inhibitor of protein synthesis) nor tamoxifen (1 microM; blocker of estrogenic receptors) modified the effects of estradiol. Estradiol (100 microM) also blocked the contractile response to serotonin (10 microM) but not to caffeine (10 mM). In addition, estradiol (100 microM) inhibited the contractile responses to cyclopiazonic acid (1 microM; selective Ca(2+)-ATPase inhibitor) associated with capacitative Ca(2+) influx through non-L-type Ca(2+) channels. Finally, estradiol inhibited the Ca(2+)-induced increases in intracellular free Ca(2+) (after pretreatment with phenylephrine) in cultured rat aorta smooth muscle cells incubated in Ca(2+)-free solution. In conclusion, estradiol interfered in a concentration-dependent manner with Ca(2+)-dependent contractile effects mediated by the stimuli of alpha(1)-adrenergic and serotonergic receptors and inhibited the capacitative Ca(2+) influx through both L-type and non-L-type Ca(2+) channels. Such effects are in essence nongenomic and not mediated by the intracellular estrogenic receptor.

Animals↗

Continuous venovenous renal replacement therapy with a pulsatile tubular blood pump: analysis of efficacy parameters.

A three-valve pulsatile tubular pump was used in 10 pigs weighing 9.9+/-0.3 kg, connected to a neonatal hemofiltration (HF) circuit to analyze the parameters to determine the ultrafiltration effectiveness for venovenous continuous renal replacement therapy. Forty 30-min periods were studied to analyze the influence of the catheter diameter, purification technique (HF or hemodiafiltration), pump pulsation frequency, percentage time in diastole, percentage time in diastole in which the post pump valve was closed, and percentage time in systole in which the post filter valve was closed, on ultrafiltrate volume and blood flow through the filter. A higher ultrafiltrate flow was achieved with a frequency of 60 bpm than with 30 bpm, a diastolic time of 65% of the total cycle versus 50%, and a blood flow of greater than 20 mL/min versus less than 20 mL/min. The ultrafiltrate flow increases in relation to the blood flow, the frequency of the pump, and the diastolic time.

Animals↗

[Evaluation of left ventricular function with a 16-slice multidetector tomograph (MDCT-16): correlation with cardiovascular magnetic resonance imaging].

UNLABELLED: The evaluation of Left ventricular function has both prognostic as well as therapeutic implications in patients with heart disease. Non-invasive coronary angiography with computed tomography using 16 slices (MDCT-16) allows to obtain images of the coronary anatomy due to its high spatial and temporal resolution, and also, to obtain data regarding Left ventricular function. The objective of this study was to correlate the use of MDCT-16 for the evaluation of the Left ventricular parameters using MRI as the Standard of reference. METHODS: MRI: Se A 1.5 Tesla GE CvI Scanner optimized for cardiovascular applications was used. Using an ECG gated steady state fast precession sequence (SSFP, Thickness 10 mm, Flip Angle 45, FOV 36 cm. NEX 1, Frequency 256, Phase 128, Partial FOV 0.75, 16VPS), 6 to 8 short axis images of from base to apex of the left ventricle were obtained. Tomography: Using a 16 slice Multidetector tomograph (GE Lightspeed) and using ECG synchronization, images of the heart were obtained after the administration of 80 mls. of no-ionic contrast. The images were reconstructed off-line to obtain from 6 to 8 slices in a similar fashion to that of MR. Both studies were independently analyzed by 2 operators who obtained the ventricular function data. Linear correlation and a Paired T Student test was used to analyze the data and was considered significant when p < 0.05. RESULTS: 20 consecutive patients were evaluated with MDCT-16 and MRI, 18 males, mean age 52 +/- 15 years. There was no significant difference among the measurements for cardiac CT and MRI of the end-diastolic volume (EDV) and end-sistolic volume (ESV), stroke volume (SV), LV Mass or LV ejection fraction (LVEF). CONCLUSION: This results show a high correlation among the clinically relevant ventricular function parameters evaluated by cardiovascular CT and MRI. This findings suggest that ventricular function can be successfully evaluated along with the coronary anatomy using MDCT-16.

Coronary Angiography↗