Comparison of transthoracic and transesophageal three-dimensional echocardiography for assessment of atrial septal defect diameter in children.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Daniel Roux.
Explore the source record for details and available documents.
A simple and quick technique to fashion a mitral ring was developed using a stainless steel wire covered by a Gore-Tex strip. This technique allows a 15-fold reduction in the cost of a mitral ring compared with commercially available rings. As such, cardiac surgery becomes more readily available to patients in developing countries such as Africa and Asia. These homemade rings were implanted in 6 patients with similar results to commercially available rings.
AIMS: Our aims were to use transthoracic three-dimensional echocardiography to assess the morphology of atrial septal defects in children prior to closure, and to compare the three-dimensional echocardiographic data with transcatheter and surgical findings. METHODS AND RESULTS: We used transthoracic three-dimensional echocardiography in 62 consecutive patients, aged from 2 to 18 years, with atrial septal defects, measuring the maximal diameter and the extent of the rims. Subsequent to the study, we referred 42 patients for transcatheter closure, the rims being measured at greater than 4 mm. We found a good correlation between the maximal diameter of the defect as measured at transthoracic three-dimensional echocardiography and using a balloon (y = 3.45 - 0.73x; r = 0.78; p < 0.0001), the mean difference between the measurements being 2.4 +/- 2.8 mm. Successful closure with the Amplatzer septal occluder, having a mean size of 22 +/- 4 mm, was achieved in 95% of the patients. Of the original cohort, 20 patients were referred for surgical closure. In these patients, the inferior rim had been deemed insufficient in 5, the postero-superior rim in 6, and the postero-inferior rim in 9. Complete agreement was found when the deficiency of the rim as judged using transthoracic three-dimensional echocardiography was compared with intraoperative findings. The correlation between measurements of the deficiency of the rim achieved by transthoracic three-dimensional echocardiography and at surgery was excellent (y = 0.2 + 0.98x; r = 0.93; p < 0.0001), the mean difference between the measurements being no more than 0.6 +/- 0.4 mm. CONCLUSIONS: Transthoracic three-dimensional echocardiography proved accurate in measuring the maximal diameter and rims of atrial septal defects within the oval fossa. This non-invasive method will be valuable in selecting children for transcatheter or surgical closure of such defects.
Explore the source record for details and available documents.
When the port of entry of acute type-A aortic dissection is at the level of the horizontal portion of the aortic arch, the latter should be replaced by a prosthesis. To avoid performing this difficult procedure in an emergency situation, we place a stent in the aortic arch. Then we replace the ascending aorta by a prosthesis.
Aortoesophageal and aortobronchial fistulas constitute a problem in therapy because of the high rates of morbidity and mortality associated with operation. From May 1996 to March 2000, we treated by an endovascular procedure one aortoesophageal and three aortobronchial fistulas. There was no postoperative death. We noted one peripheral vascular complication that required a surgical procedure, one postoperative confusion, and one inflammatory syndrome. In one case, because of a persistent leakage after 21 months, we had to implant a second endovascular stent graft. A few weeks later the reopening of this patient's esophageal fistula led to his death by mediastinitis 25 months after the first procedure. The few cases published seem to bear out the interest, observed in our 4 patients, of an endovascular approach to treat complex lesions such as fistulas of the thoracic aorta especially in emergency or palliative cases.
A 25-year-old Marfan patient was operated on for an acute type A aortic dissection that was complicated twice by false aneurysms at the distal suture line. At the third episode a covered endoprosthesis was inserted in the ascending aorta between the coronary ostia and the inominate artery. The postoperative course was uneventful and a control computed tomographic scan showed complete occlusion of the false aneurysm. This attractive technique should be considered versus an open-heart operation in selected patients.