PubMed Health⌕ Search

Biomedical subjects

Daniel Roy

Publications and source records attributed to Daniel Roy.

17 recordsLinked to original sources

Follow-up of treated aneurysms: the challenge of recurrences and potential solutions.

Angiographic recurrences after endovascular treatment of aneurysms with platinum coils are frequent, but hemorrhages are unusual. Recurrences are more frequent in patients with large wide-necked aneurysms, when the initial occlusion is incomplete, and when patients are treated after subarachnoid hemorrhage. Although many occur early on, they can appear years after treatment. None of the recent devices has been proven effective in improving long-term results. A rigorous scientific approach, including randomized trials, is imperative to forward progress in this field.

Angioplasty↗

In situ beta-irradiation of a brain arteriovenous malformation model.

BACKGROUND AND PURPOSE: The treatment of large brain arteriovenous malformations (BAVMs) is challenging, and embolization alone is seldom curative. The study goal is to enhance the efficacy of arteriovenous malformation embolization by adding a beta-emitting isotope to the embolic agent. METHODS: The pig rete mirabile was used as a BAVM model. The body distribution of radioactivity was evaluated after selective rete injection of N-butyl,2-cyanoacrylate mixed with (131)I-lipiodol in 8 animals using immediate whole body gamma-scintigraphy. Activities within the whole rete mirabile and selected tissue samples were quantified with a gamma counter immediately after sacrifice. Two pigs were submitted to serial gamma-scintigraphies for 6 weeks to detect delayed isotope leaching. Long-term effects of in situ irradiation were evaluated using a mixture of 188Re/N-butyl,2-cyanoacrylate in 8 pigs. In 1 animal, autoradiography was performed to evaluate local rete mirabile distribution of the radioactivity. Seven pigs were injected with 188Re/glue in 1 rete mirabile and with glue only on the opposite side, and the degree of vascular occlusion of both sides was compared on histology at 2 (n=2) or 6 months (n=5). RESULTS: There was negligible activity outside the target. Radiation caused occlusion of vessels unreached by the glue itself but in the vicinity of the radioactive source in 5 of 7 rete mirabile. CONCLUSIONS: Selective deposition of a beta-emitter inside a BAVM model may be achieved by current embolization techniques. The adjunct use of an isotope may increase the efficacy of embolization.

Animals↗

Production of radioactive particles for endovascular therapeutic interventions.

Recanalization is a common phenomenon that decreases the efficacy of embolization procedures. It can be inhibited by beta-radiation. Two novel ways of producing radioactive particles are described, by neutron beam irradiation of gold-containing microspheres, or by using the 32P binding capacity of zirconium-containing microspheres. Particles were tested in vivo, to assess their ability to deliver radioactivity locally, using canine renal artery, porcine rete mirabile, and rabbit ear embolization models. Both radioactive microspheres (198Au and 32P) showed no detectable activity outside the target territory. 32P microspheres demonstrated typical radiation changes in a porcine rete mirabile arteriovenous malformation model.

Animals↗

Complications of ENT infections: pseudoaneurysm of the internal carotid artery.

Ear, nose and throat infections are common, especially in children and young adults. Since the advent of antibiotics, complications from tonsillitis and pharyngeal abscess are rare, but potentially lethal. Vascular complications can be imaged with Doppler ultrasound and CT scan. The treatment of infectious vascular complications represents a significant challenge. We describe the case of a young girl presenting with a pseudoaneurysm of the internal carotid and thrombosis of the internal jugular vein. Endovascular therapy was utilized to treat the patient.

Aneurysm, False↗

Lingual artery bifurcation aneurysms for training and evaluation of neurovascular devices.

We present a canine lingual artery bifurcation aneurysm and assess its value for training in endovascular techniques and testing new embolic agents. The experimental aneurysm described herein mirrors human bifurcation aneurysms, and with this model, we sought to reproduce endovascular technical difficulties. However, the lesions created in this canine model did not show angiographic or histologic evidence of aneurysmal recurrence. We conclude that this model may be useful for training in endovascular techniques, but because of the lack of sufficient aneurysmal recurrence, it is not suitable for evaluating new embolic agents.

Aneurysm↗

Endovascular treatment of intracranial aneurysms with radioactive coils: initial clinical experience.

BACKGROUND AND PURPOSE: Endovascular treatment of intracranial aneurysms is safe and effective but is associated with angiographic recurrences. Beta radiation prevents recanalization after coil embolization in experimental models. We wanted to assess the feasibility of using radioactive coil embolization to improve long-term results of endovascular treatment. METHODS: Platinum coils were ion-implanted with 0.13 to 0.26 microCi/cm of 32P. Forty-one patients aged 34 to 84 years with 44 aneurysms with a high propensity for recurrences were included. Radioactive coils were introduced into aneurysms to reach a target volumetric activity of 0.018 microCi/mm3. Nonradioactive coils were also used to ensure the same safety and the same angiographic results as the standard procedure. Angiographic results, procedure-related complications, and neurological events during follow-up were recorded. Angiographic follow-up data are available in 36 lesions 6 months after treatment. RESULTS: Forty of 44 aneurysms (91%) could be treated with radioactive coils. Target activities could be reached in 88% of lesions that could actually be coiled (35/40). Total activities ranged from 1.72 to 80.9 microCi, for a mean of 20.13+/-20.80 microCi. Procedure-related complications occurred in 7% of patients. Initial angiographic results were satisfactory (complete occlusions or residual necks) in 75% of lesions. Angiographic recurrences occurred in 11 (31%) of patients followed, within the expected range for standard coils. There was no complication from beta radiation during a mean follow-up period of 10 months. CONCLUSIONS: Radioactive coil embolization is feasible; target volumetric activities can be reached in most aneurysms considered for endovascular treatment.

Adult↗

Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils.

BACKGROUND AND PURPOSE: Our aim in this study was to assess the incidence and determining factors of angiographic recurrences after endovascular treatment of aneurysms. METHODS: A retrospective analysis of all patients with selective endosaccular coil occlusion of intracranial aneurysms prospectively collected from 1992 to 2002 was performed. There were 501 aneurysms in 466 patients (mean+/-SD age, 54.20+/-12.54 years; 74% female). Aneurysms were acutely ruptured (54.1%) or unruptured (45.9%). Mean+/-SD aneurysm size was 9.67+/-5.91 mm with a 4.31+/-1.97-mm neck. The most frequent sites were basilar bifurcation (27.7%) and carotid ophthalmic (18.0%) aneurysms. Recurrences were subjectively divided into minor and major (ideally necessitating re-treatment). The most significant predictors of angiographic recurrence were determined by logistic regression. These results were confirmed by chi2, t tests, or ANOVAs followed, when appropriate, by Tukey's contrasts. RESULTS: Short-term (< or =1 year) follow-up angiograms were available in 353 aneurysms (70.5%) and long-term (>1 year) follow-up angiograms, in 277 (55%), for a total of 383 (76.5%) followed up. Recurrences were found in 33.6% of treated aneurysms that were followed up and that appeared at a mean+/-SD time of 12.31+/-11.33 months after treatment. Major recurrences presented in 20.7% and appeared at a mean of 16.49+/-15.93 months. Three patients (0.8%) bled during a mean clinical follow-up period of 31.32+/-24.96 months. Variables determined to be significant predictors (P<0.05) of a recurrence included aneurysm size > or =10 mm, treatment during the acute phase of rupture, incomplete initial occlusions, and duration of follow-up. CONCLUSIONS: Long-term monitoring of patients treated by endosaccular coiling is mandatory.

Cerebral Angiography↗

High-concentration ethylene-vinyl alcohol copolymer and endovascular treatment of experimental aneurysms: feasibility of embolization without protection devices at the neck.

BACKGROUND AND PURPOSE: Coiling of intracranial aneurysms is both safe and effective but may be followed by recurrences. The purpose of this study was to assess the feasibility of endovascular treatment of aneurysms with high-concentration ethylene-vinyl alcohol copolymer (HCEVOH), without the use of protection devices at the neck. METHODS: Wide-necked bifurcation aneurysms with a high propensity for recurrences were constructed in 22 dogs. HCEVOH embolization was performed with a dedicated high-pressure microcatheter in 12 animals. Angiographic results at 3 and 12 weeks and pathologic results at 12 weeks were compared with those of a separate group of 10 animals treated with platinum coils. We used a qualitative scoring system to grade angiographic results, neointima formation, and recanalization at the neck. RESULTS: Intraaneurysmal HCEVOH injections could be performed without carotid emboli and without a protection device in 11 of 12 animals. Fragments detached upon traction of the microcatheters at the end of the procedure on two occasions. Immediate and late angiographic results were not significantly different between the two groups (P =.807), with a tendency for angiographic recurrences at 3 months (angiographic scores were significantly worse in both groups at 12 weeks as compared with T0 [P <.02]). A complete occlusion, including the neck, even at the cost of protrusion of material at the level of the branches, is necessary to decrease risks of recurrences. Neointima formation at the surface of the embolic agent was complete at the neck of aneurysms treated with HCEVOH. The neointimal score was significantly improved with HCEVOH as compared with coil embolization (P =.03). CONCLUSION: HCEVOH embolization of aneurysms without neck protection is feasible. It does not, however, eliminate recurrences in an experimental wide-necked aneurysm model.

Animals↗

Cyanoacrylate embolization of experimental aneurysms.

BACKGROUND AND PURPOSE: Cyanoacrylates are effective occlusive agents in neurovascular interventions. To study their potential to improve long-term results of endovascular treatment of aneurysms, we conducted experimental studies in canine aneurysm models. METHODS: Venous pouch carotid aneurysms were constructed in dogs. Results of coil embolization of lateral wall and bifurcation aneurysms were compared. A lateral wall model of embolization with gelatin sponges was used to study the effects of coating sponges with cyanoacrylate on angiographic results and neointima thickness at 3 and 12 weeks. These models were also used to investigate the control of endovascular cyanoacrylate deposition, alone or over a coil placed at the neck of the treated lesions. The results of endovascular cyanoacrylate embolization of bifurcation aneurysms were compared with those of coil embolization at 3 months. RESULTS: Bifurcation aneurysms treated with coils showed more frequent recurrences (P <.01) and thinner neointimas (P <.01) at 3 months than did lateral wall aneurysms. Cyanoacrylate-coated sponges improved angiographic results (P <.05) and led to thicker neointimas at 3 and 12 weeks (P <.05) as compared with uncoated sponges. Endovascular cyanoacrylate deposition with microcatheters led to stray emboli in all cases. Cyanoacrylate delivery was improved by a single coil positioned at the neck of the aneurysm, but parent vessel embolization still occurred in 25% of the animals. Cyanoacrylate embolization of bifurcation aneurysms improved angiographic results at 3 months as compared with coil embolization (P <.01). CONCLUSION: Cyanoacrylate embolization is currently difficult to control. It has the potential to decrease recurrences after endovacular treatment of aneurysms, but a safe method for endovascular delivery has yet to be developed.

Animals↗

Endovascular treatment of experimental wide neck aneurysms: comparison of results using coils or cyanoacrylate with the assistance of an aneurysm neck bridge device.

BACKGROUND AND PURPOSE: Endovascular treatment of wide neck aneurysms often results in incomplete occlusion or aneurysm recurrence. The two goals of the present study were to compare results of coil embolization with or without the assistance of an aneurysm neck bridge device (ANBD) and to explore the use of this instrument to control cyanoacrylate embolization. METHODS: Wide necked bifurcation aneurysms were constructed in 28 dogs. Coil embolization of the aneurysms was performed 2 to 4 weeks later, with (n = 11) or without (n = 10) ANBD assistance. In seven other animals, embolization was performed with cyanoacrylate, injected under the protection of ANBDs. Angiographic results were compared immediately after and at 3 and 12 weeks. Neointima formation at the neck was also compared between groups at 12 weeks. RESULTS: Initial angiographic results and recurrences at 12 weeks were not significantly different in aneurysms coiled with or without ANBDs. Neointimal scores were also similar. The use of one ANBD at the neck was not sufficient to safely deliver cyanoacrylate into aneurysms. Cyanoacrylate embolization led to improved angiographic results (P =.05) and to better neointimal sealing of the neck of the aneurysms at 12 weeks (P =.004). CONCLUSION: ANBDs did not prevent recanalization and recurrences after coil embolization of wide neck aneurysms in this animal study. ANBD-assisted cyanoacrylate embolization was unsafe but could decrease recurrences at 12 weeks.

Animals↗