PubMed Health⌕ Search

Biomedical subjects

Daniele Andreuccetti

Publications and source records attributed to Daniele Andreuccetti.

3 recordsLinked to original sources

Quasi-static electromagnetic dosimetry: from basic principles to examples of applications.

An overview of quasi-static electromagnetic dosimetry is presented. After an introductive description of quantities and standards and a quick look at experimental and analytical approaches, attention is focused on numerical dosimetry. The process that leads to the calculation of results is analyzed in its basic steps, including the representation of the human body by means of a realistic voxel phantom. The most popular numerical methods are then described. An analysis of different methods in the same framework emphasizes common features and differences. This can help in choosing a more suitable method to solve a particular problem. An example of an application is finally reported.

Dose-Response Relationship, Radiation↗

Extremely low-frequency electromagnetic fields do not affect DNA damage and gene expression profiles of yeast and human lymphocytes.

We studied the effects of extremely low-frequency (50 Hz) electromagnetic fields (EMFs) on peripheral human blood lymphocytes and DBY747 Saccharomyces cerevisiae. Graded exposure to 50 Hz magnetic flux density was obtained with a Helmholtz coil system set at 1, 10 or 100 microT for 18 h. The effects of EMFs on DNA damage were studied with the single-cell gel electrophoresis assay (comet assay) in lymphocytes. Gene expression profiles of EMF-exposed human and yeast cells were evaluated with DNA microarrays containing 13,971 and 6,212 oligonucleotides, respectively. After exposure to the EMF, we did not observe an increase in the amount of strand breaks or oxidated DNA bases relative to controls or a variation in gene expression profiles. The results suggest that extremely low-frequency EMFs do not induce DNA damage or affect gene expression in these two different eukaryotic cell systems.

Blood Proteins↗

ELF magnetic field exposure in a neonatal intensive care unit.

In this paper, the magnetic flux density (MFD) distribution in a neonatal intensive care unit is described and MFD values inside a few open infant warming systems and incubators are reported. Typical measured values of the magnetic flux density at power frequency (50 Hz) in the "general environment" (the rooms of the unit) were lower than 0.2 microT, while higher MFD values were detected close to medical equipment and inside the open infant warming systems. In both cases, the magnetic flux density quickly decreases with increasing distance, so that measured values are reduced to "background" (i.e., general environment) levels 20-30 cm away from the sources. The total harmonic content over the 100-800 Hz frequency range was also evaluated. In the general environment, measured values in this band were negligible, while this was not the case close to medical equipment. Field levels inside the open and closed incubators depend on the position of the electronic control system, of the heating power generator and its winding conductor, and of the 220 V main plug. The magnetic flux density was also monitored for a prolonged period of time in a few types of open infant warming systems and incubators under standard intensive care unit operation with premature newborn present.

Electric Power Supplies↗