Diffuse optical tomography system to image brain activation with improved spatial resolution and validation with functional magnetic resonance imaging.

Although most current diffuse optical brain imaging systems use only nearest- neighbor measurement geometry, the spatial resolution and quantitative accuracy of the imaging can be improved through the collection of overlapping sets of measurements. A continuous-wave diffuse optical imaging system that combines frequency encoding with time-division multiplexing to facilitate overlapping measurements of brain activation is described. Phantom measurements to confirm the expected improvement in spatial resolution and quantitative accuracy are presented. Experimental results showing the application of this instrument for imaging human brain activation are also presented. The observed improvement in spatial resolution is confirmed by functional magnetic resonance imaging.

Brain↗

Time-gated optical system for depth-resolved functional brain imaging.

We present a time-domain optical system for functional imaging of the adult head. We first describe the instrument, which is based on a Ti:Sapphire pulsed laser (wavelength 750-850 nm) and an intensified CCD camera enabling parallel detection of multiple fibers. We characterize the system in terms of sensitivity and signal-to-noise ratio, instrument response function, cross-talk, stability, and reproducibility. We then describe two applications of the instrument: the characterization of baseline optical properties of homogeneous scattering media, and functional brain imaging. For the second application, we developed a two-part probe consisting in two squares of 4 x 4 sources and 3 x 3 detectors. The laser source is time-multiplexed to define 4 states of 8 sources that can be turned on during the same camera frame while minimizing cross-talk. On the detection side, we use for each detector 7 fibers of different lengths creating an optical delay, and enabling simultaneous detection in 7 windows (by steps of 500 ps) for each detector. This multiple window detection allows depth sensitivity. The imaging probe was tested on dynamic phantoms and a preliminary result on an adult performing a motor task shows discrimination between superficial and cortical responses to the stimulus on both hemispheres.

Adult↗

Diffuse optical imaging of the whole head.

Near-Infrared Spectroscopy (NIRS) and diffuse optical imaging (DOI) are increasingly used to detect hemodynamic changes in the cerebral cortex induced by brain activity. Until recently, the small number of optodes in NIRS instruments has hampered measurement of optical signals from diverse brain regions. Our new DOI system has 32 detectors and 32 sources; by arranging them in a specific pattern, we can cover most of the adult head. With the increased number of optodes, we can collect optical data from prefrontal, sensorimotor, and visual cortices in both hemispheres simultaneously. We describe the system and report system characterization measurements on phantoms as well as on human subjects at rest and during visual, motor, and cognitive stimulation. Taking advantage of the system's larger number of sources and detectors, we explored the spatiotemporal patterns of physiological signals during rest. These physiological signals, arising from cardiac, respiratory, and blood-pressure modulations, interfere with measurement of the hemodynamic response to brain stimulation. Whole-head optical measurements, in addition to providing maps of multiple brain regions' responses to brain activation, will enable better understandings of the physiological signals, ultimately leading to better signal processing algorithms to distinguish physiological signal clutter from brain activation signals.

Adult↗