PubMed Health⌕ Search

Biomedical subjects

Dapeng Wu

Publications and source records attributed to Dapeng Wu.

5 recordsLinked to original sources

Double-cross hydrostatic pressure sample injection for chip CE: variable sample plug volume and minimum number of electrodes.

A novel sample injection method for chip CE was presented. This injection method uses hydrostatic pressure, generated by emptying the sample waste reservoir, for sample loading and electrokinetic force for dispensing. The injection was performed on a double-cross microchip. One cross, created by the sample and separation channels, is used for formation of a sample plug. Another cross, formed by the sample and controlling channels, is used for plug control. By varying the electric field in the controlling channel, the sample plug volume can be linearly adjusted. Hydrostatic pressure takes advantage of its ease of generation on a microfluidic chip, without any electrode or external pressure pump, thus allowing a sample injection with a minimum number of electrodes. The potential of this injection method was demonstrated by a four-separation-channel chip CE system. In this system, parallel sample separation can be achieved with only two electrodes, which is otherwise impossible with conventional injection methods. Hydrostatic pressure maintains the sample composition during the sample loading, allowing the injection to be free of injection bias.

Electrodes↗

Grafting epoxy-modified hydrophilic polymers onto poly(dimethylsiloxane) microfluidic chip to resist nonspecific protein adsorption.

In order to achieve a simple covalent hydrophilic polymer coating on poly(dimethylsiloxane) (PDMS) microfluidic chip, epoxy modified hydrophilic polymers were synthesized in aqueous solution with a persulfate radical initiation system, and crosslinked onto PDMS pretreated by oxygen plasma and silanized with 3-aminopropyl-triethoxysilanes (APTES). Glycidyl methacrylate (GMA) was copolymerized with acrylamide (poly(AAM-co-GMA)) or dimethylacrylamide (poly(DAM-co-GMA)), and graft polymerized with polyvinylpyrrolidone (PVP-g-GMA) or polyvinylalcohol (PVA-g-GMA). The epoxy groups in the polymers were determined by UV spectra after derivation with benzylamine. Reflection absorption infrared spectroscopy (RAIRS) confirmed covalent grafting of GMA-modified polymers onto PDMS surface. Electroosmotic flow (EOF) in the polymer grafted microchannel was strongly suppressed within the range pH 3-11. Surface adsorption of lysozyme and bovine serum albumin (BSA) was reduced to less than 10% relative to that on the native PDMS surface. On the GMA-modified polymer coated PDMS microchip, basic proteins, peptides, and sodium dodecyl sulfate (SDS) denatured proteins were separated successfully.

Acrylamides↗

Multilayer poly(vinyl alcohol)-adsorbed coating on poly(dimethylsiloxane) microfluidic chips for biopolymer separation.

A poly(dimethylsiloxane) (PDMS) microfluidic chip surface was modified by multilayer-adsorbed and heat-immobilized poly(vinyl alcohol) (PVA) after oxygen plasma treatment. The reflection absorption infrared spectrum (RAIRS) showed that 88% hydrolyzed PVA adsorbed more strongly than 100% hydrolyzed one on the oxygen plasma-pretreated PDMS surface, and they all had little adsorption on original PDMS surface. Repeating the coating procedure three times was found to produce the most robust and effective coating. PVA coating converted the original PDMS surface from a hydrophobic one into a hydrophilic surface, and suppressed electroosmotic flow (EOF) in the range of pH 3-11. More than 1,000,000 plates/m and baseline resolution were obtained for separation of fluorescently labeled basic proteins (lysozyme, ribonuclease B). Fluorescently labeled acidic proteins (bovine serum albumin, beta-lactoglobulin) and fragments of dsDNA phiX174 RF/HaeIII were also separated satisfactorily in the three-layer 88% PVA-coated PDMS microchip. Good separation of basic proteins was obtained for about 70 consecutive runs.

DNA↗

Genotyping the -6A/G functional polymorphism in the core promoter region of angiotensinogen gene by microchip electrophoresis.

Angiotensinogen (AGT) gene has been regarded as one of the candidate genes for essential hypertension. In our study, the role of AGT gene as a putatively predisposing gene for hypertension was evaluated by genotyping a A (-6) G polymorphism in the core promoter region in 123 patients with essential hypertension and 103 healthy controls. A microchip electrophoresis method coupled with polymorphism chain reaction (PCR)-restriction fragment length polymorphism (RFLP) assay was used for genotyping the A (-6) G single-nucleotide polymorphism. The separation and detection of the digested PCR amplicons were completed just in 280 s or less. The genotype frequency fulfilled the criteria of the Hardy-Weinbery equilibrium (X2 = 3.067, P > 0.05). The results showed a higher frequency of the -6 A allele (0.70) in the normotensive subjects, which is higher than those reported in Germany (0.47) and Czech (0.40) populations, but similar to that found in Japanese populations (0.73). The frequencies of genotype AA, AG, and GG were 0.46, 0.49, and 0.05 in hypertensive subjects, and 0.44, 0.53, and 0.03 in control subjects. There is no significant difference in the distributions of the genotype and allele between the two groups (X2 = 0.88, P > 0.05; X2 = 0.024, P > 0.05). These findings differ from some of the results obtained in other ethnic groups, indicating the potential importance of ethnic origin in the assessment of genetic risk identifiers for a complex disease.

Aged↗

Determination of SARS-coronavirus by a microfluidic chip system.

We have developed a new experimental system based on a microfluidic chip to determine severe acute respiratory syndrome coronavirus (SARS-CoV). The system includes a laser-induced fluorescence microfluidic chip analyzer, a glass microchip for both polymerase chain reaction (PCR) and capillary electrophoresis, a chip thermal cycler based on dual Peltier thermoelectric elements, a reverse transcription-polymerase chain reaction (RT-PCR) SARS diagnostic kit, and a DNA electrophoretic sizing kit. The system allows efficient cDNA amplification of SARS-CoV followed by electrophoretic sizing and detection on the same chip. To enhance the reliability of RT-PCR on SARS-CoV detection, duplex PCR was developed on the microchip. The assay was carried out on a home-made microfluidic chip system. The positive and the negative control were cDNA fragments of SARS-CoV and parainfluenza virus, respectively. The test results showed that 17 positive samples were obtained among 18 samples of nasopharyngeal swabs from clinically diagnosed SARS patients. However, 12 positive results from the same 18 samples were obtained by the conventional RT-PCR with agarose gel electrophoresis detection. The SARS virus species can be analyzed with high positive rate and rapidity on the microfluidic chip system.

Autopsy↗