PubMed Health⌕ Search

Biomedical subjects

Daqing Piao

Publications and source records attributed to Daqing Piao.

11 recordsLinked to original sources

Endoscopic, rapid near-infrared optical tomography.

This is believed to be the first demonstration of near-infrared (NIR) optical tomography employed at the endoscope scale and at a rapid sampling speed that allows translation to in vivo use. A spread-spectral-encoding technique based on a broadband light source and linear-to-circular fiber bundling was used to provide endoscopic probing of many source-detector fibers for tomography as well as parallel sampling of all source-detector pairs for rapid imaging. Endoscopic NIR tomography at an 8 Hz frame rate was achieved in phantoms and tissue specimens with a 12 mm probe housing eight sources and eight detectors. This novel approach provides the key feasibility studies to allow this blood-based contrast imaging technology to be attempted in detection of cancer in internal organs via endoscopic interrogation.

Computer Systems↗

Video-rate near-infrared optical tomography using spectrally encoded parallel light delivery.

A novel parallel source implementation approach to near-infrared tomography is demonstrated through spectral encoding of the light delivery. This new technique allows many sources to be input into the tissue at the same time, and a high-resolution spectrometer is used to spatially spread out the signals from each spectrally encoded source. The parallel sampling of all sources at all detection locations renders rapid imaging. Acquisition of complete tomographic data sets at a video rate of 35 frames/s is achieved for imaging of a 6.35 mm diameter inclusion with an absorption coefficient of 0.01 mm(-1) and a reduced scattering coefficient of 1.5 mm(-1) that is moving along a circular path inside a 1% Intralipid solution.

Computer Systems↗

Characterization of dentin, enamel, and carious lesions by a polarization-sensitive optical coherence tomography system.

Enamel and dentin are the primary components of human teeth. Both of them have a strong polarization effect. We designed a polarization-sensitive optical coherence tomography (PSOCT) system to study the spatially resolved scattering and polarization phenomena of teeth. The system is constructed in free space to avoid the complexity of polarization control in fiber-based PSOCT. The structural features of enamel were evaluated in five human teeth that had no visible evidence of caries. The teeth were subsequently sectioned in mesial distal orientation and coronal orientation. Then the structural aspects of dentin were evaluated. OCT images were made of the mantel dentin near the dentin-enamel junction. Five teeth with interproximal and occlusal caries were also studied. With two channel and phase-retardation images, PSOCT provided better functional contrast and more detailed structural information than conventional OCT. For a better description of the measured PSOCT data, we classify these features by two types, i.e., the local textural features and the global structural features. This study indicates that PSOCT has the potential to be a powerful tool for research of dental formation and caries diagnosis.

Algorithms↗

Direct bidirectional angle-insensitive imaging of the flow signal intensity in Doppler optical coherence tomography.

We introduce a new method, to our knowledge, for direct detection of flow signal intensity by stationary target rejection. In our system, two delay lines are constructed with identical scanning speed and ranging depth. One delay line is used for depth ranging as well as phase modulation, and the other one acts as a full-range retroreflector (FRRR). The signal from this FRRR carries the overall features of local phase modulation, and it is used as the local oscillator for coherent demodulation. With this setup, stationary targets can be rejected at a 4-kHz high-pass cutoff frequency of the filter that follows the demodulator, compared with 20 kHz for conventional fixed-frequency demodulation. This technique features angle insensitivity and provides flow direction as well by implementing standard in-phase and quadrature detection. Besides the direct directional detection of flow signal intensity, flow speed information can be acquired with postprocessing.

Hemorheology↗

Simultaneous optical coherence tomography imaging and beta particle detection.

A prototype hybrid catheter device designed for imaging and detection of vascular diseases is introduced. The prototype device integrates a high-resolution optical coherent tomography probe and a high-sensitivity beta detector into a single unit. With this prototype device we demonstrate the feasibility of simultaneous optical coherence tomography imaging and detection of beta particles.

Beta Particles↗

Quantifying Doppler angle and mapping flow velocity by a combination of Doppler-shift and Doppler-bandwidth measurements in optical Doppler tomography.

Recently we introduced a novel procedure that estimates Doppler angle and flow velocity simultaneously by combining Doppler-shift and Doppler-bandwidth measurements with a conventional single-beam optical Doppler tomography device. Here we validate this method experimentally with two Intralipid flow setups that correspond to fixed Doppler angle and fixed flow speed. One set of data has a fixed flow speed of 53.6 mm/s with a Doppler angle that changes from 56 degrees to 90 degrees; the other has a fixed Doppler angle of 80 degrees with flow speed that changes from 18.5 to 141.9 mm/s. As obtained with the method introduced here, the Doppler-angle estimation accuracies of the two sets are 97.6% and 98.2%, respectively, and the estimation accuracies of flow speeds of the two sets are 94.3% and 90.4%, respectively.

Algorithms↗

Doppler angle and flow velocity mapping by combined Doppler shift and Doppler bandwidth measurements in optical Doppler tomography.

Accurate estimation of flow velocity requires measurement of Doppler angle, which is not available in general clinical applications. We describe a novel method of direct Doppler angle and flow velocity mapping that uses a conventional single-beam optical Doppler tomography system. The Doppler angle is estimated by combination of Doppler shift and Doppler bandwidth measurements, and flow velocity is calculated from the Doppler shift and the estimated Doppler angle. In vivo study of lip microvascularization demonstrates that this method is capable of providing both flow speed and flow direction information.

Blood Flow Velocity↗

Quantitative assessment of flow velocity-estimation algorithms for optical Doppler tomography imaging.

We present a quantitative comparison of three categories of velocity estimation algorithms, including centroid techniques (the adaptive centroid technique and the weighted centroid technique), the sliding-window filtering technique, and correlation techniques (autocorrelation and cross correlation). We introduce, among these five algorithms, two new algorithms: weighted centroid and sliding-window filtering. Simulations and in vivo blood flow data are used to assess the velocity estimation accuracies of these algorithms. These comparisons demonstrate that the sliding-window filtering technique is superior to the other techniques in terms of velocity estimation accuracy and robustness to noise.

Algorithms↗

Digital signal processor-based real-time optical Doppler tomography system.

We present a real-time data-processing and display unit based on a custom-designed digital signal processor (DSP) module for imaging tissue structure and Doppler blood flow. The DSP module is incorporated into a conventional optical coherence tomography system. We also demonstrate the flexibility of embedding advanced Doppler processing algorithms in the DSP module. Two advanced velocity estimation algorithms previously introduced by us are incorporated in this DSP module. Experiments on Intralipid flow demonstrate that a pulsatile flow of several hundred pulses per minute can be faithfully captured in M-scan mode by this DSP system. In vivo imaging of a rat's abdominal blood flow is also presented.

Abdomen↗

Portable near-infrared diffusive light imager for breast cancer detection.

We present a frequency-domain near-infrared optical tomography system designed for breast cancer detection, in conjunction with conventional ultrasound. It features fast optical switching, three-wavelength excitations, and avalanche photodiode as detectors. Laser diodes at 660, 780, and 830 nm are used as light sources and their outputs are distributed sequentially to one of nine source fibers. An equivalent 130-dB isolation between electrical signals from different source channels is achieved with the optical switches of very low crosstalk. Ten detection channels, each of which includes a silicon avalanche photodiode, detect diffusive photon density waves simultaneously. The dynamic range of an avalanche photodiode is about 20 to 30 dB higher than that of a photomultiplier tube, thus eliminating the need for multistep system gain control. The entire system is compact in size (<0.051 m(3)) and fast in data acquisition (less than 2 sec for a complete scan). Calibration and the clinical experiment results are presented in the paper.

Algorithms↗

Hybrid positron detection and optical coherence tomography system: design, calibration, and experimental validation with rabbit atherosclerotic models.

We evaluate the performance of our novel hybrid optical coherence tomography (OCT) and scintillating probe, demonstrate simultaneous OCT imaging and scintillating detection, and validate the system using an atherosclerotic rabbit model. Preliminary data obtained from the rabbit model suggest that our prototype positron probe detects local uptake of fluorodeoxyglucose (FDG) labeled with 18F positron (beta) radionuclide emitter, and the high-uptake regions correlate with sites of injury and extensive atherosclerosis areas. Preliminary data also suggest that coregistered high-resolution OCT images provide imaging of detailed plaque microstructures, which cannot be resolved by positron detection.

Animals↗