The influence of the Stiles-Crawford peak location on visual performance.

We investigated the influence of the Stiles-Crawford peak location on visual acuity, contrast sensitivity and phase transfer with 6 mm diameter pupils in two subjects. Apodising filters were used to move the peak. One subject (SM) had her natural peak 0.9 mm below pupil centre, and visual performance was measured for both this peak position and when the peak was moved to the same distance above pupil centre. The other subject (DAA) had a more centred peak and visual performance was measured for this peak position and when the peak was moved both 2.3 mm temporally and 2.6 mm nasally. Measurements of contrast sensitivity and phase transfer were compared with predictions based on aberration measurements. The peak position had definite influence on performance, but this was mainly noticeable when subjects were defocused e.g. SM's visual acuity was reduced by 0.13 log units under the peak-shifted condition at -2D (hypermetropic) defocus.

Adult↗

Scatter and its implications for the measurement of optical image quality in human eyes.

PURPOSE: To investigate the effect of scatter on measurements of wavefront aberrations and point-spread functions in a model eye. METHODS: The wavefront aberrations of a model eye were measured using Hartmann-Shack wavefront sensing and crossed-cylinder aberroscope techniques and compared with its measured point-spread function in the presence of scattering media of different concentrations. RESULTS: The point-spread functions became broader as the concentration increased. Forward light scatter on both the light path into the eye and the light path out of the eye contributed to this broadening of the point-spread function. Neither the crossed-cylinder aberroscope nor wavefront sensing, which, respectively, measure the ocular wavefront aberrations for light entering the eye and leaving the eye, were affected by the scatter. CONCLUSION: We predict that by minimizing the contribution of the forward light scatter from one or other of these light paths by manipulating the size of the entrance and exit pupils, it should be possible to objectively assess narrow-angle forward light scatter in the eye by measuring and removing any confounding effect from wavefront aberration.

Diagnostic Techniques, Ophthalmological↗

Who needs optics?

Explore the source record for details and available documents.

Education, Medical, Undergraduate↗

Hartmann-Shack technique and refraction across the horizontal visual field.

We compared refractions across the horizontal visual field, based on different analyses of wave aberration obtained with a Hartmann-Shack instrument. The wave aberrations had been determined for 6-mm-diameter pupils up to at least the sixth Zernike order in five normal subjects [J. Opt. Soc. Am. A 19, 2180 (2002)]. The polynomials were converted into refractions based on 6-mm pupils and second-order Zernike aberrations (6 mm/2nd order), 3-mm pupils and second-order aberrations (3 mm/2nd order), 1-mm pupils and second-order aberrations (1 mm/2nd order), and 6-mm pupils with both second- and fourth-order aberrations (6 mm/4th order). The 3-mm/2nd-order and 6-mm/2nd-order refractions differed by as much as 0.9 D in mean sphere on axis, but the differences reduced markedly toward the edges of the visual field. The cylindrical differences between these two analyses were small at the center of the visual field (<0.3 D) but increased into the periphery to be greater than 1.0 D for some subjects. Much smaller differences in mean sphere and cylinder were found when 3-mm/2nd-order refractions and either the 1-mm/2nd-order refractions or the 6-mm/4th-order refractions were compared. The results suggest that, for determining refractions based on wave aberration data with large pupils, similar results occur by either restricting the analysis to second-order Zernike aberrations with a smaller pupil such as 3 mm or using both second- and fourth-order Zernike aberrations. Since subjective refraction is largely independent of the pupil size under photopic conditions, objective refractions based on either of these analyses may be the most useful.

Adult↗

The Stiles-Crawford effect and subjective measurement of aberrations.

We considered the influence that the Stiles-Crawford effect (SCE) has on the measurement of subjective monochromatic and transverse aberration measurements. The SCE was measured with a two channel Maxwellian-viewing system. Transverse aberrations were measured using a vernier alignment technique in three subjects, with the natural SCE operating, with the SCE neutralised by filters optically conjugate with the eye's pupil, and for one subject with filters that shifted the SCE by more than 2 mm. As pupil diameter increased from 1 to 5 mm diameter, without the filters the slope of the transverse aberration versus position in the pupil decreased, e.g. for chromatic aberration this decreased by approximately 90%. The filters had little influence on transverse aberration. The results indicate that subjects do not use the centroid of the image of a blurred line target for alignment, but may rely very much on other cues.

Color Perception↗

Contrast sensitivity and the Stiles--Crawford effect.

We investigated the influence of the Stiles-Crawford effect (SCE) of the first kind on the contrast sensitivity function using the apodisation model of the SCE. The SCE was measured for the right eyes of two subjects using an increment threshold technique involving a two-channel Maxwellian-viewing system. Filters made of photographic film neutralised or doubled the SCE. Contrast sensitivities were measured with a 6 mm pupil diameter, defocus to +/-2D, and three SCE conditions (normal, neutralised and doubled). Modulation transfer functions were derived after measuring transverse aberrations with a vernier alignment technique, and were used to predict contrast sensitivity functions (CSFs). The measured CSFs were, in general, reasonable matches with the predicted CSFs. In particular, both demonstrated definite undulations ("notches") as defocus level increased. The influences of the SCE-modifying filters were generally of similar magnitude and direction to predictions, thus supporting the apodisation model of the SCE. The magnitudes of SCE influence between SCE-neutralised and SCE-doubled conditions were usually small at about 0.2-0.3 log unit, with a maximum influence of 0.5 log unit. Influences of the SCE were greater for myopic than for hypermetropic defocus. As measured by the CSF and an apodisation model, this study is in agreement with previous theoretical work and one experimental study in indicating that the SCE plays a minor role in improving spatial visual performance.

Contrast Sensitivity↗

Theoretical analysis of peripheral imaging after excimer laser corneal refractive surgery for myopia.

PURPOSE: To explore theoretically the retinal point images in the peripheral fields of eyes that have had excimer laser refractive surgery. University research laboratory. METHODS: Model eyes were based on Navarro's finite schematic eye, the eyes being made myopic by an increase in axial length. To simulate photorefractive keratectomy (PRK), the anterior shape and thickness of the cornea were modified. Variables included pupil size, ablation zone size, preexisting refractive error, and the addition of a blending zone. Image-quality criteria for each retinal point image were its size and the angular separation of the centroids of those parts of the image produced by rays passing through ablated and unablated corneal zones. RESULTS: In the peripheral visual field, the boundary between the ablated and unablated cornea caused a separation of the retinal image of a single point into 2 parts. The separation increased with the preexisting refractive error. Image quality was correspondingly reduced by ablation. As pupil size increased, the field angle at which the retinal image doubling first occurred decreased. Increasing the diameter of the ablation zone or using a blending zone increased the angle at which the doubling first occurred, and the blending zone improved image quality considerably. Chromatic effects appeared to be relatively unimportant. CONCLUSIONS: This analysis provides further evidence of the disadvantages of small central ablation zones in excimer laser refractive surgery and of the advantages of well-designed blending zones in improving postsurgical peripheral image quality. Image quality in the peripheral field of the pseudoemmetropic post-PRK eye is generally worse than in a naturally emmetropic eye, even though the axial image quality may be similar.

Humans↗

Monocular accommodation response for totally occluded objects.

PURPOSE: To investigate the accuracy and stability of the monocular accommodation response when attention is directed toward a totally occluded distant object. METHODS: A static infrared optometer was used to measure the monocular accommodative response in 16 participants while they viewed a distant letter target in the presence or absence of an intervening object that totally occluded the distant target from view. Participants were instructed to attend to and focus for the distant target. RESULTS: Participants differed widely in their accommodative responses for a totally occluded distant object, focusing close to the distant object, close to the intervening object, in between the two objects, and beyond the distant object. Some of this variability could be attributed to individual differences in the dark focus. Accommodation was more variable when the distant target was totally occluded by an obstruction at an intermediate distance (50 cm). CONCLUSIONS: Many individuals focus poorly in the presence of a visual obstruction that totally occludes the object of regard.

Accommodation, Ocular↗

Designing lenses to correct peripheral refractive errors of the eye.

The purpose of this work was to design ophthalmic lenses that correct peripheral refractive errors of human eyes along a meridian. We designed lenses with the tangential section of one surface based on a figured spheroid but figured in the tangential section only. The curvature of the sagittal section of this surface was adjusted separately. A merit function was used to modify these surfaces until the lenses had power errors that corrected the eye. Examples are presented of lenses that correct a schematic eye. They do excellent jobs of correcting the peripheral power errors of the eye and are relatively insensitive to small changes in fitting distance. We conclude that it is theoretically feasible to design lenses to correct peripheral refractive errors.

Equipment Design↗

Influence of Stiles-Crawford apodization on visual acuity.

The Stiles-Crawford effect (SCE) of the first kind has often been considered to be important to spatial visual performance in that it ameliorates the influence of defocus and aberrations. We investigated the influence of SCE apodization on visual acuity as a function of defocus (out to +/-2 D) in four subjects. We used optical filters, conjugate with the eye's entrance pupil, that neutralized or doubled the existing SCE. With an illiterate-E task, the influence of the SCE was more noticeable for myopic defocus than for hypermetropic defocus, was generally more noticeable for high-contrast than for low-contrast letters, and increased with increase in pupil size. The greatest influence on visual acuity of neutralizing the SCE, across the subjects and range of conditions, was deterioration of 0.06 (4-mm pupil), 0.16 (6-mm pupil), and 0.29 log unit (7.6-mm pupil).

Contrast Sensitivity↗

Monochromatic aberrations of human eyes in the horizontal visual field.

We measured the monochromatic aberrations of five subjects' right eyes both temporally and nasally out to 40 degrees from fixation. We used a Hartmann-Shack sensor with modifications to equipment and software to enable off-axis measurements. Results were standardized for 6-mm pupils. There was considerable variation among subjects in the pattern of aberrations. Aberrations were generally greater in the nasal visual field than in the temporal visual field; in the case of third-order aberrations, this was true for all subjects. The contribution of third-order Zernike aberrations to the root-mean-square aberration increased up to four times from the center to the edge of the field, but the contribution of fourth- to sixth-order Zernike aberrations varied little across the visual field. Results were similar to those of a previous investigation using laser ray tracing and were of the order of those predicted by Navarro's finite schematic eye.

Comment↗

Effect of an intervening screen on accommodation to a distant object.

Background: An intervening screen has been suggested to induce an inward shift of accommodation when viewing a distant object. This is an example of the Mandelbaum effect. However, there have been no objective measures of the magnitude of this effect in this particular situation. Methods: Accommodation was recorded with an infra-red optometer, while subjects (n = 16) viewed a distant letter target with or without an intervening screen. Screens were placed near the individual dark focus distance or at 50 cm. In a second experiment the contrast of the distant target was varied and subjects (n = 5) viewed the target directly or through a screen placed near the individual dark focus distance. Results: In the main experiment, the Mandelbaum effect was not significantly different from zero and was less than 0.5 D in every subject. In addition, accommodation was not more variable when viewing through the screen. However, it may be that some subjects do demonstrate a Mandelbaum effect while others do not. The individual dark focus level did not predict susceptibility to the Mandelbaum effect for a screen at the dark focus. Subjects reported their perceptions of the tasks and some noted changes in the perceived distances of objects when viewing through a screen. In the second experiment, the Mandelbaum effect (< 0.6 D) did not vary with distant target contrast. Conclusions: When viewing a distant object through a screen there is a small (< 0.6 D) or negligible inward shift of accommodation.