PubMed Health⌕ Search

Biomedical subjects

David A LaVan

Publications and source records attributed to David A LaVan.

8 recordsLinked to original sources

Electropolymerization on microelectrodes: functionalization technique for selective protein and DNA conjugation.

A critical shortcoming of current surface functionalization schemes is their inability to selectively coat patterned substrates at micrometer and nanometer scales. This limitation prevents localized deposition of macromolecules at high densities, thereby restricting the versatility of the surface. A new approach for functionalizing lithographically patterned substrates that eliminates the need for alignment and, thus, is scalable to any dimension is reported. We show, for the first time, that electropolymerization of derivatized phenols can functionalize patterned surfaces with amine, aldehyde, and carboxylic acid groups and demonstrate that these derivatized groups can covalently bind molecular targets, including proteins and DNA. With this approach, electrically conducting and semiconducting materials in any lithographically realizable geometry can be selectively functionalized, allowing for the sequential deposition of a myriad of chemical or biochemical species of interest at high density to a surface with minimal cross-contamination.

Benzaldehydes↗

Approaches for biological and biomimetic energy conversion.

This article highlights areas of research at the interface of nanotechnology, the physical sciences, and biology that are related to energy conversion: specifically, those related to photovoltaic applications. Although much ongoing work is seeking to understand basic processes of photosynthesis and chemical conversion, such as light harvesting, electron transfer, and ion transport, application of this knowledge to the development of fully synthetic and/or hybrid devices is still in its infancy. To develop systems that produce energy in an efficient manner, it is important both to understand the biological mechanisms of energy flow for optimization of primary structure and to appreciate the roles of architecture and assembly. Whether devices are completely synthetic and mimic biological processes or devices use natural biomolecules, much of the research for future power systems will happen at the intersection of disciplines.

Biology↗

Diaphragmatic repair through fetal tissue engineering: a comparison between mesenchymal amniocyte- and myoblast-based constructs.

PURPOSE: We have previously shown that fetal tissue engineering is a preferred alternative to diaphragmatic repair in a large animal model. This study was aimed at comparing diaphragmatic constructs seeded with mesenchymal amniocytes and fetal myoblasts in this model. METHODS: Neonatal lambs (n = 14) underwent repair of an experimental diaphragmatic defect with identical scaffolds, either seeded with labeled autologous cells (mesenchymal amniocytes in group 1 and fetal myoblasts in group 2) or as an acellular graft (group 3). At 1 to 12 months postoperatively, implants were harvested for multiple analyses. RESULTS: Repair failure (reherniation or eventration) was significantly higher in group 3 than in groups 1 and 2, with no difference between groups 1 and 2. Seeded fetal myoblasts quickly lost their myogenic phenotype in vivo. All grafts contained cells with a fibroblastic-myofibroblastic profile. Elastin concentrations and both modular and ultimate tensile strengths were significantly higher in group 1 than in groups 2 and 3. There were no differences in glycosaminoglycans and type I collagen levels among the groups. CONCLUSIONS: Diaphragmatic repair with a mesenchymal amniocyte-based engineered tendon leads to improved structural outcomes when compared with equivalent fetal myoblast-based and acellular grafts. The amniotic fluid is a preferred cell source for tissue-engineered diaphragmatic reconstruction.

Animals↗

In vivo evaluation of tetrahedral amorphous carbon.

The in vivo behavior and tissue reaction to tetrahedral amorphous carbon (ta-C) has been evaluated for periods of up to 6 months in SV129 mice. Two sample types were tested--silicon die coated with ta-C (n = 53) and micromachined particles (n = 40). The coated samples were compared to uncoated silicon die (n = 22). Die samples were implanted subcutaneously, and tissue reaction and capsule formation were evaluated at various time points. Micromachined particles of 1, 3, 10, and 30 microm were injected adjacent to the sciatic nerve, and tissue samples were examined histologically at various time points (4 days-6 months). Tissue reaction to ta-C was mild and was localized to the area of the injection or implantation. Samples with a higher ratio of 3-fold bonding appeared to shed material during the experiments; this was not observed on samples with a higher level of 4-fold bonding, nor on uncoated silicon die. The results strongly suggest that films with greater 4-fold bonding character (more diamond-like) are more resistant to in vivo fragmentation than films with higher 3-fold character (more graphitic).

Animals↗

Fabrication and biocompatibility of polypyrrole implants suitable for neural prosthetics.

Finding a conductive substrate that promotes neural interactions is an essential step for advancing neural interfaces. The biocompatibility and conductive properties of polypyrrole (PPy) make it an attractive substrate for neural scaffolds, electrodes, and devices. Stand-alone polymer implants also provide the additional advantages of flexibility and biodegradability. To examine PPy biocompatibility, dissociated primary cerebral cortical cells were cultured on PPy samples that had been doped with polystyrene-sulfonate (PSS) or sodium dodecylbenzenesulfonate (NaDBS). Various conditions were used for electrodeposition to produce different surface properties. Neural networks grew on all of the PPy surfaces. PPy implants, consisting of the same dopants and conditions, were surgically implanted in the cerebral cortex of the rat. The results were compared to stab wounds and Teflon implants of the same size. Quantification of the intensity and extent of gliosis at 3- and 6-week time points demonstrated that all versions of PPy were at least as biocompatible as Teflon and in fact performed better in most cases. In all of the PPy implant cases, neurons and glial cells enveloped the implant. In several cases, neural tissue was present in the lumen of the implants, allowing contact of the brain parenchyma through the implants.

Animals↗

Small-scale systems for in vivo drug delivery.

Recent developments in the application of micro- and nanosystems for drug administration include a diverse range of new materials and methods. New approaches include the on-demand activation of molecular interactions, novel diffusion-controlled delivery devices, nanostructured 'smart' surfaces and materials, and prospects for coupling drug delivery to sensors and implants. Micro- and nanotechnologies are enabling the design of novel methods such as radio-frequency addressing of individual molecules or the suppression of immune response to a release device. Current challenges include the need to balance the small scale of the devices with the quantities of drugs that are clinically necessary, the requirement for more stable sensor platforms, and the development of methods to evaluate these new materials and devices for safety and efficacy.

Biosensing Techniques↗

Moving smaller in drug discovery and delivery.

Advances in new micro- and nanotechnologies are accelerating the identification and evaluation of drug candidates, and the development of new delivery technologies that are required to transform biological potential into medical reality. This article will highlight the emerging micro- and nanotechnology tools, techniques and devices that are being applied to advance the fields of drug discovery and drug delivery. Many of the promising applications of micro- and nanotechnology are likely to occur at the interfaces between microtechnology, nanotechnology and biochemistry.

Drug Delivery Systems↗