Flow rate calibration. III. The use of stabilized biostandards to calibrate the flow rate and calculate absolute CD4+ T-cell counts.

BACKGROUND: We have previously reported a flow rate calibration method for the determination of absolute CD4(+) T-lymphocyte counts that removes the need for the addition of latex beads to each sample. However, a limitation with this approach is that a calibration factor (CF) needs to be applied to adjust for differences in viscosity between latex bead suspensions and biological specimens. We have also demonstrated the value of using stabilized whole blood samples in external quality assessment (EQA) studies; such samples have a stable absolute lymphocyte count for over 1 year, at 4 degrees C. It was successfully demonstrated that this material can be used as a flow rate biocalibration (FRB) material for use as a flow cytometric control to provide a sample with a known CD4(+) T-lymphocyte count. Such material has advantages over latex bead technology as it can act as a full process control as well as having the same matrix and viscosity characteristics as the test material, thus removing the need for a CF. METHODS: In this study, we have analyzed 268 consecutive normal, abnormal, and HIV(+) samples using FRB, incorporating the PanLeucoGating approach and compared this to the MultiSet method, defined as the predicate. RESULTS: Percentage similarity statistics revealed the following: 0-3,000 CD4(+) cells/mul mean percentage difference (MPD; bias) 1.2%, 95% CI of 5.6-8%; 0-200 CD4(+) cells/microl MPD of 1.25%, 95% CI of 11.63-14.13%; 201-500 CD4(+) cells/microl MPD of 1%, 95% CI of 4.6-6.6%. DISCUSSION: This study demonstrates that stabilized whole blood can be used for FRB. It has the advantage of being a full process control, in addition to costing less than latex beads with highly comparable results. As bench top flow cytometers are extremely stable, this is a low cost and robust alternative to bead based methods for generating absolute CD4 counts.

Algorithms↗

Paragraph text reading using a pixelized prosthetic vision simulator: parameter dependence and task learning in free-viewing conditions.

PURPOSE: To investigate the feasibility of adequate reading by recipients of future prosthetic visual implants through simulation in sighted observers. METHODS: Four normally sighted subjects used a video headset to view short-story segments at a sixth grade reading level, presented in 6- to 11-word paragraphs through a pixelizing grid defined by five parameters (dot size, grid size, dot spacing, random dropout percentage, and gray-scale resolution). Grid parameters were varied individually, and four character sizes and two contrast levels were used. RESULTS: Reading speeds of 30 to 60 words per minute without errors were recorded for some parameter combinations. In general, reading accuracy and speed were influenced by all parameters. Reading accuracy exceeded 90% if the following conditions were met: At least 3 dots/charwidth were presented, and dropout did not exceed 50%. Reading speed deteriorated below 20 words per minute if accuracy fell below 90% and at low contrast if the grid spanned less than two characters. CONCLUSIONS: It is uncertain whether and to what extent retinal reorganization may limit the perception of multiple phosphenes by blind prosthesis recipients. If distinct phosphenes can be perceived, these results suggest that a 3 x 3-mm2 prosthesis with 16 x 16 electrodes should allow paragraph reading. The effects of stabilizing the dot grid on the retina must be investigated further.

Adult↗

Multicentre evaluation of stable reference whole blood for enumeration of lymphocyte subsets by flow cytometry.

BACKGROUND: Clinical indications for lymphocyte subset enumeration by flow cytometry include monitoring of disease progression and timing of therapeutic intervention in infection with human immunodeficiency virus. Until recently international standardisation has not been possible due to a lack of suitable stable reference material. METHODS: This study consisted of two trials of a stabilised whole blood preparation. Eleven participants were sent two standard protocols for staining plus gating strategy and asked to report absolute counts for lymphocyte subsets. RESULTS: No significant difference was detected between the two methods when results from the two assays and all partners were pooled. Significant differences in results from the different partners were observed. However, representative mean counts were obtained for geometric means, geometric coefficient of variation, and 95% confidence interval for CD3 910 cells/mul, 9%, and 888 to 933, respectively), CD4 (495 cells/mul, 12%, and 483 to 507), and CD8 (408 cells/mul, 13%, and 393 to 422). CONCLUSION: We have introduced a stabilised blood preparation and a well-characterized biological standard. The availability of this reference material greatly simplifies the validation of new techniques for CD4(+) T-cell enumeration and the expansion of external quality assurance programmes for clinical laboratories, including those that operate in resource-restricted environments. (c) 2005 Wiley-Liss, Inc.

Journal Article↗

Perfect count: a novel approach for the single platform enumeration of absolute CD4+ T-lymphocytes.

BACKGROUND: The derivation of reliable CD4(+) T lymphocyte counts is vital for the monitoring of disease progression and therapeutic effectiveness in HIV(+) individuals. Flow cytometry has emerged as the method of choice for CD4(+) T lymphocyte enumeration, with single-platform technology, coupled with reference counting beads, fast becoming the "gold standard." However, although single-platform, bead-based, sample acquisition requires the ratio of beads to cells to remain unchanged, there is no available method, until recently, to monitor this. METHODS: Perfect Count beads have been developed to address this issue and to incorporate two bead populations, with different densities, to allow the detection of inadequate mixing. Comparison of the relative proportions of both beads with the manufacture's defined limits enables an internal QC check during sample acquisition. In this study, we have compared CD4(+) T lymphocyte counts, obtained from 104 HIV(+) patients, using TruCount beads with MultiSet software (defined as the predicated method) and the new Perfect Count beads, incorporating an in house sequential gating strategy. RESULTS: We have demonstrated an excellent degree of correlation between the predicate method and the Perfect Count system (r(2) = 0.9955; Bland Altman bias +27 CD4(+) T lymphocytes/microl). CONCLUSIONS: The Perfect Count system is a robust method for performing single platform absolute counts and has the added advantage of having internal QC checks. Such an approach enables the operator to identify potential problems during sample preparation, acquisition and analysis.

CD4-Positive T-Lymphocytes↗

Enumeration of antigen-specific CD8+ T lymphocytes by single-platform, HLA tetramer-based flow cytometry: a European multicenter evaluation.

BACKGROUND: HLA class I peptide tetramers represent powerful diagnostic tools for detection and monitoring of antigen-specific CD8(+) T cells. The impetus for the current multicenter study is the critical need to standardize tetramer flow cytometry if it is to be implemented as a routine diagnostic assay. Hence, the European Working Group on Clinical Cell Analysis set out to develop and evaluate a single-platform tetramer-based method that used cytomegalovirus (CMV) as the antigenic model. METHODS: Absolute numbers of CMV-specific CD8(+) T cells were obtained by combining the percentage of tetramer-binding cells with the absolute CD8(+) T-cell count. Six send-outs of stabilized blood from healthy individuals or CMV-carrying donors with CMV-specific CD8(+) T-cell counts of 3 to 10 cells/microl were distributed to 7 to 16 clinical sites. These sites were requested to enumerate CD8(+) T cells and, in the case of CMV-positive donors, CMV-specific subsets on three separate occasions using the standard method. RESULTS: Between-site coefficients of variation of less than 10% (absolute CD8(+) T-cell counts) and approximately 30% (percentage and absolute numbers of CMV-specific CD8(+) T cells) were achieved. Within-site coefficients of variation were approximately 5% (absolute CD8(+) T-cell counts), approximately 9% (percentage CMV-specific CD8(+) T cells), and approximately 17% (absolute CMV-specific CD8(+) T-cell counts). The degree of variation tended to correlate inversely with the proportion of CMV-specific CD8(+) T-cell subsets. CONCLUSIONS: The single-platform MHC tetramer-based method for antigen-specific CD8(+) T-cell counting has been evaluated by a European group of laboratories and can be considered a reproducible assay for routine enumeration of antigen-specific CD8(+) T cells.

CD8-Positive T-Lymphocytes↗

Inhibitors directed towards caspase-1 and -3 are less effective than pan caspase inhibition in preventing renal proximal tubular cell apoptosis.

BACKGROUND: Uncontrolled apoptosis contributes to tubular cell deletion in renal scarring. Caspase-3 has a central role in the execution of apoptosis and may provide a target for regulating cell death. Here we evaluate three caspase inhibitors: B-D-FMK (pan caspase inhibitor), Z-DEVDFMK (predominantly Caspase-3 inhibitor) and Z-VAD-FMK (predominantly Caspase-1 and -3 inhibitor) to ameliorate apoptosis induced by cisplatin in rat proximal tubular (RPT) cells. METHODS: Caspase-3 activity (substrate cleavage assay) and protein (immunocytochemistry and Western blotting), apoptosis (Annexin V flow cytometry, in situend labelling of fragmented DNA, light/electron microscopy and DNA laddering) and cell survival (trypan blue exclusion and propidium iodide flow cytometry) were determined in RPT cells exposed to cisplatin with and without caspase inhibitors. RESULTS: Cisplatin induced a dose-dependent increase in Caspase-3 activity and 8-fold of increase in apoptosis (p < 0.01) when applied for 24 h at 100 microM. B-D-FMK (40 microM), Z-DEVD-FMK (15 microM) and Z-VAD-FMK (22 microM) almost completely inhibited the 25-fold increase in Caspase-3 activity and decreased apoptosis from 15.9 +/- 4.4 to 2.0 +/- 0.6% (p < 0.01), 15.0 +/- 2.2 and 15.0 +/- 2.2% respectively. DNA ladders were visible in cisplatin-treated cells, which disappeared following addition of B-D-FMK and decreased with Z-VAD-FMK and Z-DEVD-FMK. Cisplatin reduced cell survival to 61% by trypan blue exclusion. B-D-FMK and Z-VAD-FMK increased this to 87 and 75%, but Z-DEVD-FMK had no significant effect. CONCLUSIONS: Cisplatin causes an increase in RPT apoptosis that is associated with increased Caspase-3 activity. All caspase inhibitors were equally effective at reducing Caspase-3 activity, however the pan caspase inhibitor B-D-FMK was more effective at preventing apoptosis and increasing cell survival. Therefore, pan caspase inhibition offers the greatest potential for the prevention of renal tubular cell deletion by uncontrolled apoptosis.

Amino Acid Chloromethyl Ketones↗

Flow rate calibration II: a clinical evaluation study using PanLeucoGating as a single-platform protocol.

BACKGROUND: CD4(+) T-lymphocyte enumeration is vital for monitoring disease progression in individuals positive for the human immunodeficiency virus (HIV), and as a result, there is a need to develop cost-effective protocols that provide accuracy, precision, and affordability. Recently, PanLeucoGating has been shown to fulfill these requirements; however, although comparable to state-of-the-art single-platform protocols (SP), there is still a requirement for an accurate total white cell count. To overcome this limitation, we recently developed a flow-rate based calibration method that enables the PanLeucoGating protocol to be used as a SP approach, and in this study show that this approach can be used for CD4(+) T-lymphocyte enumeration. METHODS: A total of 113 HIV samples were analyzed using three protocols: (a) state-of-the art SP bead-based method (MultiSet; predicate protocol), (b) PanLeucoGating protocol used as a dual-platform (DP) approach, and (c) the newly developed flow rate-based SP approach. We demonstrate that flow rate calibration can be achieved easily and that the method is highly comparable to the state-of-the-art SP method. RESULTS: A high correlation was observed between the predicate protocol and the SP PanLeucoGating approach over the whole range of CD4 counts tested (r(2) = 0.9928; bias 8 cells/microl), including the clinically relevant range (e.g., 0-200 CD4 cells/microl; bias 0 cells/microl). For batched samples, the cost of providing a CD4(+) T-lymphocyte count was reduced to approximately US $1. CONCLUSIONS: The SP PanLeucoGating is a cost-effective approach to CD4(+) T-lymphocyte enumeration that maintains accuracy and precision.

Animals↗

Flow rate calibration I: a novel approach for performing absolute cell counts.

BACKGROUND: Reports suggest that flow rate (FR) is constant on bench top flow cytometers. Therefore, if FR is constant, the volume acquired in a fixed time period will also be constant, enabling absolute leucocyte counting using flow rate calibration (FRC). METHODS: FR stability was ascertained on a standard FACSCalibur by counting TruCount beads suspended in phosphate buffered saline over 120 s. Studies using two lysing solutions (FACS lysing solution and PharM Lyse) and corresponding sample lysates established a lysing solution calibration factor (CF). Absolute CD4(+) T-lymphocyte counts on 10 peripheral blood samples determined using FRC were compared with the predicate method TruCount/MultiTEST, incorporating MultiSET software. Linearity studies were also performed at three different flow rates. RESULTS: A high degree of linearity over a wide range of counts (50 to >1,600 CD4(+) T lymphocytes/microl) at all three pressures was observed. Importantly, there was no significant difference from the predicate method when appropriate lysing solution CF was used. CONCLUSIONS: Using a simple calibration procedure and incorporation of an appropriate lysing solution CF, we show that FRC can easily be performed. The technical details that underpin this novel approach for absolute leucocyte enumeration are provided.

CD4 Lymphocyte Count↗

The cancer technology appraisal programme of the UK's National Institute for Clinical Excellence.

The National Institute for Clinical Excellence (NICE) was established to ensure faster and more equitable uptake of new technologies by the NHS, through the provision of guidance on clinical and cost-effectiveness. The treatment of cancer is one of the UK government's priority areas and a range of guidance products have been developed by NICE to support implementation of national plans for managing patients with cancer in England and Wales. In its first 3 years, NICE's main activity was the "Technology Appraisals Programme" and it has created considerable interest and some controversy. 15 (out of a total of 56) technology appraisals related to oncology have been completed and another four are in preparation. The open, transparent, and inclusive approach NICE has adopted in reaching its decisions highlights the difficult ethical issues that need to be addressed in seeking to balance individual desires with public-health requirements. In this review we describe the process of appraising technologies, and address the recent criticism of the appraisal programme with regard to treatment of patients with cancer.

Academies and Institutes↗

Stabilised cellular immuno-fluorescence assay: CD45 expression as a calibration standard for human leukocytes.

We first confirmed the precision of the quantitative indirect immunofluorescence (QIFI) test by demonstrating that blood lymphocytes from different individuals expressed CD45 leucocyte antigens at a very similar level (mean: 201 x 10(3) antibody binding capacity (ABC)/lymphocyte) with only minimal variation (CV% 2.5%). These values were maintained for 4 days in blood samples when kept at 20 degrees C, and for up to 14 days in samples fixed with TransFix. Using long-term stabilisation, after an initial drop of 10-15% the CD45 ABC/lymphocyte values remained stable at an 85-90% level for >1 year. These biological standards were used to check other quantitative IF techniques. The quantum simply cellular (QSC) method showed variable results (85-240%), and the QuantiBRITE method gave values as low as 30-40% of the expected values, indicating that biological standards such as CD45 ABC/lymphocytes are absolutely essential to check the performance of methods that claim to quantify immunofluorescence (IF). Next, these standards were used to establish the stabilised cellular immuno-fluorescence assay (SCIFA) as follows. The ABC x 10(3)/cell values established by QIFI on leucocyte populations such as lympho-, mono- and granulocytes were used to create calibration curves for the CD45 antigen and its isoforms CD45RA, -R0 and -RB. The same cell populations were then stained with monoclonal antibodies (MAbs) directly conjugated to different fluorochromes in order to translate the mean fluorescence intensity (MFI) values seen with the directly labelled reagents to values of ABCx10(3)/cells. Using SCIFA with a triple-colour direct IF, the display of CD45 and its isoforms were quantitated on the 'virgin' or 'unprimed' (CD45RA+) and 'primed' (CD45R0+) subsets in both the CD4+ and CD8+ T cell lineages. We also observed that the CD4+ and CD8+ T cells in transit between the 'virgin' and 'primed' subsets frequently displayed different levels of the CD45RA and -R0 molecules, pointing to the physiological variability of the CD45RA-R0 switching process. In conclusion, internal biological standards, with known stable expression of ABC/cell, should be used to evaluate IF staining patterns in a quantitative manner during routine investigations.

Adult↗

CD45-assisted PanLeucogating for accurate, cost-effective dual-platform CD4+ T-cell enumeration.

BACKGROUND: North American and European guidelines for dual-platform (DP) flow cytometry recommend absolute CD4 T-cell counts to be calculated from two parameters: the absolute lymphocyte counts obtained on a hematology analyzer and the percentages of CD4+ cells among lymphocytes (CD4%/lympho) obtained by flow cytometry. Nevertheless, the identification of lymphocytes is error-prone: a poor match between these common denominators in the two systems is the main source of inaccuracy. In contrast, total leucocyte counts (white cell counts [WCC]) and CD4% among the gated CD45+ leucocytes (CD4%/leuco) can be determined with greater accuracy. METHODS: We introduced "PanLeucogating," i.e., we used total leucocytes as the common denominator for improving the precision of DP absolute CD4 counting. Correlations and Bland-Altman tests were used for statistical analysis. RESULTS: First, 22 stabilized blood product samples were provided by U.K. National External Quality Assessment Scheme (NEQAS) and a higher accuracy and precision of CD4 counts were documented using PanLeucogating compared with lymphocyte gating. Next, 183 fresh and 112 fixed (TransFix) whole blood samples were used to compare DP methods and single-platform (SP) methodology, including both volumetric and bead-based techniques. A particularly high correlation and comparable precision of absolute CD4 counts were observed between the SP volumetric method and DP PanLeucogating (R(2) = 0.990; bias 6 +/- SD 17%). The SP volumetric method showed lower levels of agreement with the DP lymphocyte gating (R(2) = 0.758; bias 14 +/- SD 51%) and with the SP bead-based method (R(2) = 0.923; bias 4 +/-SD 31%). CONCLUSIONS: These observations show that DP leucocyte counts (WCC) should replace lymphocyte counts as the "common denominator" although CD4%/lympho values can, as an extra step, be also provided readily if requested. When coupled with quality control for WCC on hematology analyzers, the DP method with CD45 PanLeucogating represents a robust CD4 T-cell assay that is as accurate as the SP volumetric technique. This DP method uses only two, CD45 and CD4, antibody reagents and can be run on any pair of hematological analyzer plus flow cytometer.

CD4-Positive T-Lymphocytes↗

Precise CD4 T-cell counting using red diode laser excitation: for richer, for poorer.

BACKGROUND: Measuring CD4 T-cell counts at low cost is relevant in dealing with the human immunodeficiency virus (HIV) epidemic throughout the developing world. The recently introduced novel concepts in gating strategies and sample stabilization facilitate affordable immunophenotyping by flow cytometry. However, the impact of these developments is still limited by the high cost of currently available flow cytometers. METHODS: Diode lasers emitting 10-15 mW at 635 nm are one-tenth the size and cost and require one thousandth the power of an equivalent 488-nm argon ion laser. We used the available 635-nm diode-based flow cytometers, including PA-II, Luminex 100, SuperMot, and FACSCalibur, to investigate whether these instruments can generate reliable CD4 counts when used with allophycocyanin (APC) and cyanin-5 (Cy5)-labeled CD4 antibodies. RESULTS: We document the feasibility of obtaining leucocyte differential counts using orthogonal side scatter (SSC) without the need for forward scatter (FSC). Accurate CD4% values among lymphocytes and leucocytes can be obtained by primary CD4 gating using a single CD4 monoclonal antibody conjugated to APC or Cy5. Double immunofluorescence (IF) staining with CD4-APC (FL1) and CD45-APC-Cy7 (FL2) introduces pan-leucogating for a convenient assessment of absolute CD4 counts on double platforms. We demonstrate that small flow cytometers with laser diodes are capable of delivering absolute CD4 T-cell counts with a precision similar to the performance of the current state-of-the-art single-platform instruments (e.g., the CytoronAbsolute; R(2) = 0.961). In this respect, they appear to be superior to the nonflow CD4 counting techniques. CONCLUSIONS: Accurate CD4 counts can be generated at minimal cost on red diode laser-operated flow cytometers, retaining the potential for high throughput capacity without compromising precision. With further improvements in volumetric technology and clinical software, these cytometers may develop into a new generation of inexpensive battery-operated laboratory hardware that combines cellular phenotyping with bead-based multiplexing immunoassays for (HIV) serology.

CD4 Antigens↗

Reduction of variation in T-cell subset enumeration among 55 laboratories using single-platform, three or four-color flow cytometry based on CD45 and SSC-based gating of lymphocytes.

BACKGROUND: Enumeration of CD4(+) and CD8(+) T-cell subsets provides relevant information for diagnosis and monitoring of patients with cellular immunodeficiencies. As a result, an external quality assurance scheme was implemented in Belgium, The Netherlands, and Luxembourg in 1995. A workshop was held to train the participants in state-of-the art technology for assessment of absolute T-cell subset counts (i.e., a three or four-color, single-platform assay with lymphocyte gating based on CD45 and sideward light scatter) with the aim to achieve between-site coefficients of variation (CVs) <10% and within-site CVs <5% for > or =75% of the participants. METHODS: Three send-outs of stabilized blood from a healthy donor were distributed to 55 laboratories, each with the request to perform the standard assay on three occasions. For comparison, each laboratory performed its local technique in parallel. RESULTS: With the standard technique, between-site CVs of approximately 8% (CD3+ T cells), approximately 9% (CD4+ T cells), and approximately 10% (CD8+ T cells) were achieved. Within-site CVs were <5% for 82% (CD3+ T cells) and approximately 70% (CD4+ and CD8+ subsets) of the participants. Local techniques yielded between-site CVs of 13%-17% for CD3+, CD4+, and CD8+ T cells. CONCLUSIONS: The state-of-the-art technology for T-cell subset enumeration was implemented successfully among 55 Belgian-Dutch laboratories and resulted in significant reductions of between-site variation of absolute CD3+, CD4+, and CD8+ T-cell counts.

CD3 Complex↗

Quality control of CD4+ T-lymphocyte enumeration: results from the last 9 years of the United Kingdom National External Quality Assessment Scheme for Immune Monitoring (1993-2001).

The human immunodeficiency virus (HIV) global epidemic has necessitated the routine enumeration of T-lymphocyte subsets, which has created a need for external quality assurance (EQA). The United Kingdom National External Quality Assessment Scheme (UK NEQAS) for Immune Monitoring provides EQA for 296 laboratories in 40 countries. In 1993, UK NEQAS developed and incorporated into its program stabilized whole blood that enables the accurate monitoring of laboratory performance. Overall, the mean interlaboratory coefficient of variation (CV) for percentage CD4(+) T-lymphocyte subset enumeration has fallen from 15% to less than 5%, as a direct result of the increased use of CD45/ side scatter (SSC) gating. Laboratories using alternative gating strategies (i.e., CD45/CD14 or forward scatter [FSC]/SSC) were about 7.4 times more likely to fail an EQA exercise. Furthermore, the adoption of single-platform technology resulted in a reduction of the overall mean interlaboratory CV for absolute CD4(+) T lymphocytes from 56% (prior to the widespread use of single-platform technology) to 9.7%. Individual laboratory deficiencies were also identified using a performance monitoring system and, through re-education by collaboration with the coordinating center, satisfactorily resolved. In conclusion, during the last 9 years, the UK NEQAS for Immune Monitoring program has highlighted the significant technological advances made by laboratories worldwide that undertake lymphocyte subset enumeration.

CD3 Complex↗