PubMed Health⌕ Search

Biomedical subjects

David C Alsop

Publications and source records attributed to David C Alsop.

At least 19 recordsLinked to original sources

Combined T2* and T1 measurements for improved perfusion and permeability studies in high field using dynamic contrast enhancement.

This study analyzed the T2* effect of extracellularly distributed gadolinium contrast agents in arterial blood during tumor studies using T1-weighted sequences at high field strength. A saturation-prepared dual echo sequence with echo times of 1.5 and 3.5 ms was employed at 3 T to simultaneously characterize T1 and T2* of arterial blood during bolus administration of Gd-DTPA in 28 patients with body tumors. T2* effect and T1 effect of Gd-DTPA on image intensity of whole blood were calibrated in human blood samples with different concentrations of contrast agent. T2* was used to estimate concentration near the peak of the bolus. T1 was used to measure lower concentrations when T2* was not significant. T2* was measurable on calibration curves for Gd-DTPA concentrations higher than 4 mM. This concentration was exceeded in 18 patients. The mean signal intensity reduction because of T2* effect was estimated at 22+/-14% of the T2* compensated signal. Using T2* measurements reduced underestimations of peak arterial Gd-DTPA concentration (59 +/- 38%) and overestimation of permeability Ktrans (58%). The T2* effect of gadolinium contrast agents should therefore be accounted for when performing tumors study with T1-weighted sequences at high field strength.

Aorta↗

Measurement of arterial input functions for dynamic susceptibility contrast magnetic resonance imaging using echoplanar images: comparison of physical simulations with in vivo results.

Measurement of the arterial input bolus shape is essential to the quantification of mean transit time and blood flow with dynamic susceptibility contrast (DSC) MRI. Input functions derived from the echoplanar signal intensity within or near arteries are highly nonlinear, yet such input functions are widely used. We employed a physical model for the echoplanar signal intensity from an artery as a function of contrast agent concentration, artery size, and angle to the magnetic field to test approaches for the measurement of the arterial input function. The simulated results confirmed the strong nonlinearity of signal in the neighborhood of vessels. Of the input function measurement methods considered, the simulations suggested that measurement of signal near but not within a large vessel is most accurate, but mean transit times (MTT) calculated with these input functions are highly sensitive to peak bolus concentration. Input functions determined from voxels demonstrating the shortest first moment overestimated the MTT but the measured MTTs were more robust to changes in peak concentration. Characteristics of the measured in vivo input functions were consistent with the simulations. Our results emphasize the important contribution of input function errors to the uncertainty in MTT and blood flow imaging with DSC MRI.

Adult↗

In vivo estimation of the flow-driven adiabatic inversion efficiency for continuous arterial spin labeling: a method using phase contrast magnetic resonance angiography.

The accurate quantification of perfusion with arterial spin labeling (ASL) requires consideration of a number of factors, including the efficiency of the inversion and control pulses used for spin labeling. In this study the effects of spin velocity on continuous ASL efficiency when using the amplitude modulated control strategy were investigated using simulations of the Bloch equations. The inversion efficiency was determined in vivo by combining the simulations with phase-contrast velocity mapping data acquired at the level of the tagging plane. Using this novel method, an average inversion efficiency of 69% was calculated for a group of 28 subjects, in good agreement with experimental data reported previously. There was, however, a large range in inversion efficiency measured across the subject group (50-76%), indicating that the velocity dependence of the amplitude modulated control efficiency may introduce additional variability into the perfusion calculations if not properly taken into account.

Algorithms↗

Effects of cord motion on diffusion imaging of the spinal cord.

Measurement of diffusion and its dependence on direction has become an important tool for clinical and research studies of the brain. Diffusion imaging of the spinal cord may likewise prove useful as an indicator of tissue damage and axonal integrity; however, it is more challenging to perform diffusion imaging in the cord than in the brain. Here we report a study of the effects of motion on single-shot fast spin echo (FSE) diffusion tensor imaging (DTI) of the spinal cord. Diffusion imaging was performed at four different times in the cardiac cycle both without and with velocity compensation of the diffusion gradients. Uncompensated diffusion images demonstrated substantial signal loss artifacts in the cord that were strongly dependent on the delay after the pulse-oximeter trigger. Quantitative diffusion analysis was also strongly affected by this motion artifact. The use of flow-compensated gradients helped to restore normal signal in the cord, especially at particular trigger delays. Theoretical arguments suggest that improved spatial resolution may help eliminate this signal loss. Even with higher spatial resolution, motion-related signal attenuation may still occur in diffusion imaging of pathologies that alter the motion of the cord. However, this same cord motion may contain diagnostically valuable information when probed using appropriate diffusion imaging approaches.

Adult↗

Limits on activation-induced temperature and metabolic changes in the human primary visual cortex.

Changes in cerebral blood flow (CBF) and metabolism are now widely used to map and quantify neural activity, although the underlying mechanism for these changes is still incompletely understood. Magnetic resonance spectroscopy (MRS) at 3T, synchronized with a 32-s block design visual stimulation paradigm, was employed to investigate activation-induced changes in temperature and metabolism in the human primary visual cortex. A marginally significant increase in the local temperature of the visual cortex was found (0.1 degrees C, P = 0.09), excluding the possibility of a temperature decrease (95% confidence interval (CI) = 0.0-0.2 degrees C), which was previously suggested. A comparison with models of thermal equilibrium in the presence of blood flow suggests that an increase in heat production during activation, greater than or at least equal to that produced by the complete oxidative metabolism of the elevated glucose (Glc) utilization accompanying activation, would be required to offset the cooling effects of the increased blood flow. The total pools of glutamate (Glu), glutamine (Gln), myo-Inositol (mI), N-acetylaspartate (NAA), choline (Cho), and lactate (Lac) were not significantly affected by activation. Limits on Lac concentration changes were too weak to constrain theories of the metabolic use of elevated Glc consumption during stimulation, and emphasize the challenges of measuring even large Lac changes accompanying stimulation.

Adult↗

Cerebral blood flow velocity and periventricular white matter hyperintensities in type 2 diabetes.

OBJECTIVE: Diabetes increases the risk for cerebromicrovascular disease, possibly through its effects on blood flow regulation. The aim of this study was to assess the effects of type 2 diabetes on blood flow velocities (BFVs) in the middle cerebral arteries and to determine the relationship between white matter hyperintensities (WMHs) on magnetic resonance imaging (MRI) and BFVs. RESEARCH DESIGN AND METHODS: We measured BFVs in 28 type 2 diabetic and 22 control subjects (aged 62.3 +/- 7.2 years) using transcranial Doppler ultrasound during baseline, hyperventilation, and CO(2) rebreathing. WMHs were graded, and their volume was quantified from fluid-attenuated inversion recovery images on a 3.0 Tesla MRI. RESULTS: The diabetic group demonstrated decreased mean BFVs and increased cerebrovascular resistance during baseline, hypo- and hypercapnia (P < 0.0001), and impaired CO(2) reactivity (P = 0.05). WMH volume was negatively correlated with baseline BFV (P < 0.0001). A regression model revealed that baseline BFVs were negatively associated with periventricular WMHs, HbA(1c) (A1C), and inflammatory markers and positively associated with systolic blood pressure (R(2) = 0.86, P < 0.0001). CONCLUSIONS: Microvascular disease in type 2 diabetes, which manifests as white matter abnormalities on MRI, is associated with reduced cerebral BFVs, increased resistance in middle cerebral arteries, and inflammation. These findings are clinically relevant as a potential mechanism for cerebrovascular disease in elderly with type 2 diabetes.

Aged↗

Markedly reduced apparent blood volume on bolus contrast magnetic resonance imaging as a predictor of hemorrhage after thrombolytic therapy for acute ischemic stroke.

BACKGROUND AND PURPOSE: Accurate assessment of the risk of hemorrhage could help to improve patient selection for thrombolytic therapy and reduce hemorrhagic complications, especially for patients with longer or uncertain time after symptom onset. This study sought to define characteristics of hemodynamic magnetic resonance imaging (MRI), which best predict hemorrhage. METHODS: Bolus contrast and diffusion MRI were performed before intravenous tissue plasminogen activator (tPA) therapy in 20 patients presenting with acute stroke symptoms within the first 6 hours after symptom onset. Hemorrhage was assessed on follow-up MRI (n=15) and computed tomography (n=5) scans. RESULTS: Of the 20 patients studied, 5 had detectable hemorrhage on follow-up scans. Blood volume maps demonstrated virtually no signal within much of the hemorrhagic region, indicating contrast did not arrive by the end of the imaging series (80 seconds). Within the hemodynamically abnormal region, a threshold of at least 126 voxels with blood volume <5% of contralateral normal gray matter separated hemorrhagic patients from nonhemorrhagic with a sensitivity of 100% and a specificity of 73% (P<0.01). All subjects with hemorrhage were at least partially reperfused after thrombolysis, whereas most false-positives did not reperfuse (P<0.05). The number of low blood volume voxels within individual patients correlated with the number of voxels with apparent diffusion coefficient values <550x10(-6) mm2/s (P<0.019), another previously proposed predictor of hemorrhage. CONCLUSIONS: Extremely low or completely absent contrast arrival may indicate tissue-at-risk for hemorrhage before tPA treatment and thus may aid in risk-benefit assessments. Occurrence of hemorrhage within at-risk areas may depend on tissue reperfusion.

Adult↗

Amplitude-modulated continuous arterial spin-labeling 3.0-T perfusion MR imaging with a single coil: feasibility study.

Written informed consent was obtained prior to all human studies after the institutional review board approved the protocol. A continuous arterial spin-labeling technique with an amplitude-modulated control was implemented by using a single coil at 3.0 T. Adiabatic inversion efficiency at 3.0 T, comparable to that at 1.5 T, was achieved by reducing the amplitude of radiofrequency pulses and gradient strengths appropriately. The amplitude-modulated control provided a good match for the magnetization transfer effect of labeling pulses, allowing multisection perfusion magnetic resonance imaging of the whole brain. Comparison of multisection continuous and pulsed arterial spin-labeling methods at 3.0 T showed a 33% improvement in signal-to-noise ratio by using the former approach.

Adult↗

Efficiency of inversion pulses for background suppressed arterial spin labeling.

Background suppression strategies for arterial spin labeling (ASL) MRI offer reduced noise from motion and other system instabilities. However, the inversion pulses used for suppression can also attenuate the ASL signal, which may offset the advantages of background suppression. Numerical simulations were used to optimize the inversion efficiency of four candidate pulses over a range of radiofrequency (RF) and static magnetic field variations typical of in vivo imaging. Optimized pulses were then used within a pulsed ASL sequence to assess the pulses' in vivo inversion efficiencies for ASL. The measured in vivo inversion efficiency was significantly lower than theoretical predictions (e.g., 93% experimental compared to 99% theoretical) for the tangent hyperbolic pulse applied in a background suppression scheme. This inefficiency was supported by an in vitro study of human blood. These results suggest that slow magnetization transfer (MT) in blood, either with bound water or macromolecular protons, dominates the inversion inefficiency in blood. Despite the attenuated signal relative to unsuppressed ASL, the signal-to-noise ratio (SNR) with suppression was improved by 23-110% depending on the size of the region measured. Knowledge of efficiency will aid optimization of the number of suppression pulses and provide more accurate quantification of blood flow.

Adult↗

Arterial spin labeling blood flow magnetic resonance imaging for the characterization of metastatic renal cell carcinoma(1).

RATIONALE AND OBJECTIVE: This study sought to assess the feasibility of arterial spin labeling (ASL) blood flow (BF) magnetic resonance imaging (MRI) for the study of metastatic renal cell carcinoma (RCC) in the body, where the respiratory, cardiac, and peristaltic motions present challenges when applying ASL. MATERIALS AND METHODS: ASL was performed using a background-suppressed single-section flow-alternating inversion recovery (FAIR) preparation and a single-shot fast spin-echo imaging sequence on a 3.0-T whole body imager. Tumor BF was evaluated for 26 patients with RCC metastatic to the liver, bone, lung, or lymph nodes before VEGF receptor inhibitor therapy. Two cases with tumor size change after treatment were also scanned 1 month after therapy. For validation, kidney cortex BF in five normal volunteers was measured with the same technique and compared with literature values. RESULTS: ASL was successfully performed in all normal volunteers and in 20 of 26 patients. The six failures resulted from a systematic error, which can be avoided in future studies. For normal volunteers, measured kidney cortex BF was 275 +/- 14 mL/min/100 g, a value consistent with the literature. ASL determined tumor BF averaged across tumor volume and subjects was 194 mL/min/100 g (intersubject SD = 100), resulting in high perfusion signal and conspicuity of lesions. Bright signal was also seen in large vessels and occasionally in bowel. In the two cases studied 1 month after therapy, ASL perfusion changes were consistent with tumor size changes. CONCLUSION: With background suppression, ASL MRI is a feasible method for quantifying BF in patients with renal cell carcinoma. This technique may be useful for evaluating tumor response to antiangiogenic agents.

Antineoplastic Agents↗

Imaging melody and rhythm processing in young children.

In the adult brain, melody and rhythm processing have been found to show different hemispheric dominance, with the right hemisphere apparently more sensitive to melody and the left hemisphere to rhythm. We used a novel, child-friendly scanning protocol to examine the neural basis of melody and rhythm processing in young children (mean age 6 years 4 months, n=33). FMRI data were acquired using a sparse temporal sampling technique, taking advantage of the natural delay in the cerebrovascular response to neuronal activity. We found that this group of young children showed some differential specialization for melody and rhythm processing, but to a lesser extent than previously reported in adults. These results suggest that hemispheric specialization for musical processing may develop with age.

Acoustic Stimulation↗

Reduced susceptibility effects in perfusion fMRI with single-shot spin-echo EPI acquisitions at 1.5 Tesla.

Arterial spin labeling (ASL) perfusion contrast is not based on susceptibility effects and can therefore be used to study brain function in regions of high static inhomogeneity. As a proof of concept, single-shot spin-echo echo-planar imaging (EPI) acquisition was carried out with a multislice continuous ASL (CASL) method at 1.5T. A bilateral finger tapping paradigm was used in the presence of an exogenously induced susceptibility artifact over left motor cortex. The spin-echo CASL technique was compared with a regular gradient-echo EPI sequence with the same slice thickness, as well as other imaging methods using thin slices and spin-echo acquisitions. The results demonstrate improved functional sensitivity and efficiency of the spin-echo CASL approach as compared with gradient-echo EPI techniques, and a trend of improved sensitivity as compared with spin-echo EPI approach in the brain regions affected by the susceptibility artifact. ASL images, either with or without subtraction of the control, provide a robust alternative to blood oxygenation level dependant (BOLD) methods for activation imaging in regions of high static field inhomogeneity.

Adult↗

MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: preliminary results.

PURPOSE: To measure T1 and T2 relaxation times of normal human abdominal and pelvic tissues and lumbar vertebral bone marrow at 3.0 T. MATERIALS AND METHODS: Relaxation time was measured in six healthy volunteers with an inversion-recovery method and different inversion times and a multiple spin-echo (SE) technique with different echo times to measure T1 and T2, respectively. Six images were acquired during one breath hold with a half-Fourier acquisition single-shot fast SE sequence. Signal intensities in regions of interest were fit to theoretical curves. Measurements were performed at 1.5 and 3.0 T. Relaxation times at 1.5 T were compared with those reported in the literature by using a one-sample t test. Differences in mean relaxation time between 1.5 and 3.0 T were analyzed with a two-sample paired t test. RESULTS: Relaxation times (mean +/- SD) at 3.0 T are reported for kidney cortex (T1, 1,142 msec +/- 154; T2, 76 msec +/- 7), kidney medulla (T1, 1,545 msec +/- 142; T2, 81 msec +/- 8), liver (T1, 809 msec +/- 71; T2, 34 msec +/- 4), spleen (T1, 1,328 msec +/- 31; T2, 61 msec +/- 9), pancreas (T1, 725 msec +/- 71; T2, 43 msec +/- 7), paravertebral muscle (T1, 898 msec +/- 33; T2, 29 msec +/- 4), bone marrow in L4 vertebra (T1, 586 msec +/- 73; T2, 49 msec +/- 4), subcutaneous fat (T1, 382 msec +/- 13; T2, 68 msec +/- 4), prostate (T1, 1,597 msec +/- 42; T2, 74 msec +/- 9), myometrium (T1, 1,514 msec +/- 156; T2, 79 msec +/- 10), endometrium (T1, 1,453 msec +/- 123; T2, 59 msec +/- 1), and cervix (T1, 1,616 msec +/- 61; T2, 83 msec +/- 7). On average, T1 relaxation times were 21% longer (P <.05) for kidney cortex, liver, and spleen and T2 relaxation times were 8% shorter (P <.05) for liver, spleen, and fat at 3.0 T; however, the fractional change in T1 and T2 relaxation times varied greatly with the organ. At 1.5 T, no significant differences (P >.05) in T1 relaxation time between the results of this study and the results of other studies for liver, kidney, spleen, and muscle tissue were found. CONCLUSION: T1 relaxation times are generally higher and T2 relaxation times are generally lower at 3.0 T than at 1.5 T, but the magnitude of change varies greatly in different tissues.

Abdomen↗

Continuous arterial spin labeled perfusion magnetic resonance imaging in patients before and after carotid endarterectomy.

Continuous arterial spin labeling perfusion magnetic resonance imaging (CASL-pMRI) uses magnetically labeled arterial blood water as a tracer to obtain quantifiable measurements of cerebral blood flow (CBF) (mL/100 g-1/min-1). CASL-pMRI was used to assess CBF changes in major vascular distributions in patients (n = 10) prior to and 3 months after carotid endarterectomy (CEA). No significant change in the global baseline CBF before and after CEA was observed in the group as a whole (P = .81). In patients with reduced CBF prior to CEA (< 50 ml/100 g/min), a significant increase in global CBF following CEA was observed. An inverse relationship existed between percent change in CBF after CEA versus baseline CBF within the anterior circulation (r = -.78, P < .05) but not in the posterior distribution (r = .25, P = .63). CASL-pMRI may provide a convenient, inexpensive, noninvasive method for identifying CEA patients at risk for hyperperfusion following carotid revascularization.

Aged↗

Evaluation of systematic quantification errors in velocity-selective arterial spin labeling of the brain.

Velocity-selective (VS) sequences potentially permit arterial spin labeling (ASL) perfusion imaging with labeling applied very close to the tissue. In this study the effects of cerebrospinal fluid (CSF) motion, radiofrequency (RF) field imperfections, and sequence timing parameters on the appearance and quantitative perfusion values obtained with VS-ASL were evaluated. Large artifacts related to CSF motion were observed with moderate velocity weighting, which were removed by inversion recovery preparation at the cost of increased imaging time. Imperfect refocusing and excitation pulses resulting from nonuniform RF fields produced systematic errors in the ASL subtraction images. A phase cycling scheme was introduced to eliminate these errors. Quantitative perfusion images were obtained with CSF suppression and phase cycling. Gray matter blood flow of 27.7 ml 100 g(-1) min(-1), approximately half the value reported in studies using spatially-selective ASL, was measured. Potential sources for this underestimation are discussed.

Adult↗

Arterial transit time imaging with flow encoding arterial spin tagging (FEAST).

Arterial spin labeling (ASL) perfusion imaging provides direct and absolute measurement of cerebral blood flow (CBF). Arterial transit time is a related physiological parameter reflecting the duration for the labeled spins to reach the brain region of interest. Most of the existing ASL approaches to assess arterial transit time rely on multiple measurements at various postlabeling delay times, and thus are vulnerable to motion artifact as well as computational error. We describe the use of flow encoding arterial spin tagging (FEAST) technique to measure tissue transit time, which can be derived from the ratio between the ASL signals measured with and without appropriate bipolar gradients. In the present study, we provided a theoretical framework and carried out an experimental validation during steady-state imaging. The global mean tissue transit time was approximately 1100 and 1400 ms for two conditions of bipolar gradients with specific encoding velocity (Venc) of 29 and 8 mm/sec, respectively. The mean tissue transit time measured within cerebral vascular territories was shortest in the deep middle cerebral artery (MCA) territory. Application of the FEAST technique in two patients with cerebrovascular disease demonstrated prolonged tissue transit times in the affected vascular territories which were consistent with results from other MR imaging modalities.

Adult↗

Susceptibility contrast and arterial spin labeled perfusion MRI in cerebrovascular disease.

PURPOSE: To directly compare dynamic susceptibility contrast (DSC) and continuous arterial spin labeled (CASL) magnetic resonance (MR) perfusion techniques in patients with known cerebrovascular disease, with the goals of identifying possible pitfalls in interpretation and determining potential for a complementary role in this setting. METHODS: DSC and CASL MR perfusion studies were performed and compared in 11 patients with acute and/or chronic cerebrovascular disease. Using an automated segmentation technique, Pearson correlation coefficients were generated for CASL perfusion measurements compared to DSC perfusion maps (time-to-peak [TTP], relative cerebral blood volume [rCBV], cerebral blood flow [rCBF], and mean transit time [MTT]) by hemisphere and vascular territory. RESULTS: TTP maps obtained using DSC perfusion MR correlated best both subjectively and objectively with CASL perfusion MR measurements when all patients studied were considered. If patients with a major transit delay were excluded, DSC rCBF correlated best with CASL CBF measurements. CONCLUSION: There may be a complementary role for CASL and DSC perfusion MR methods in cerebrovascular disease, especially in the setting of a marked transit delay.

Acute Disease↗