5 recordsLinked to original sources

Diagnosis goes digital.

Accurate images of the craniofacial region are critical for the development of an orthodontic diagnosis and treatment plan. The NewTom QR 9000 Volume Scanner (QR s.r.l., Verona, Italy) represents a significant advance in imaging capabilities for dentistry and orthodontics. This new-generation scanner uses computed tomography technology to provide a complete 3D view of the maxilla and mandible with relatively high resolution and low radiation exposure to patients. This article discusses some technical aspects of this new scanner and its possible orthodontic uses.

Humans↗

Comparison between traditional 2-dimensional cephalometry and a 3-dimensional approach on human dry skulls.

The cephalogram is the standard used by orthodontists to assess skeletal, dental, and soft tissue relationships. This approach, however, is based on 2-dimensional (2D) views used to analyze 3-dimensional (3D) objects. The purpose of this project was to evaluate and compare a 3D imaging system and traditional 2D cephalometry for accuracy in recording the anatomical truth as defined by physical measurements with a calibrated caliper. Thirteen skeletal landmarks were located by both radiographic methods on 9 dry human skulls. Intraclass correlation (0.995), variance (0.054 mm(2)), and standard deviation (SD) (0.237 mm) were averaged over 76 measurements and derived from precision calipers to establish these physical measurements as a reliable gold standard to make comparisons of the 2D and 3D radiographic methods. The results showed great variability of the 2D from the gold standard, with the range varying from -17.68 mm (underestimation of Gn-Zyg R) to +15.52 mm (overestimation of Zyg L-Zyg R). In contrast, the 3D method (Sculptor, Glendora, Calif) indicated a range of the SD from -3.99 (underestimation) mm to +2.96 mm (overestimation). The 3D evaluation was much more precise, within approximately 1 mm of the gold standard. These results indicate that, when the actual distance is measured on a human skull in its true dimensions of 3D space, the Sculptor program, by using a 3D method, is more precise and 4 to 5 times more accurate than the 2D approach. Evaluating distances in 3D space with a 2D image grossly exaggerates the true measure and offers a distorted view of craniofacial growth. There is an inherent problem of representing a linear measure occupying a 3D space with a 2D image.

Analysis of Variance↗

Cone beam CT for pre-surgical assessment of implant sites.

The pre-surgical assessment of proposed implant sites requires very specific and accurate data. Imaging has always been used to assist with the implant site assessment but until the recent introduction of cone beam CT scanners, the available imaging had a low value when considering the ratio between diagnostic potential, cost of study, and risk to the patient. CBCT scanners are nearing the end of their first-generation dedicated maxillofacial imaging modalities and have proven to be an extremely useful imaging tool for pre-surgical assessment of implant sites. CBCT scanners are easy to use and produce a 3-D image volume that can be reformatted using software for customized visualization of the anatomy. Protocols have been developed that optimize the visualization of image for implant site assessment.

Adult↗