Holographic voltage profiling on 75 nm gate architecture CMOS devices.

Voltage profiles of the source-drain region of a CMOS transistor with 75nm gate architecture taken from an off-the-shelf Intel PIII processor are presented. The sample preparation using a dual beam system is discussed as well as details of the electron optical setup of the microscope. Special attention is given to the analysis of the reconstructed holograms.

Electricity↗

A method to measure the effective gas path length in the environmental or variable pressure scanning electron microscope.

A simple method is described to determine the effective gas path length when incident electrons scatter in the gas above the specimen. This method is based on the measurement of a characteristic x-ray line emitted from a region close to the incident beam. From various experimental measurements performed on various microscopes, it is shown that the effective gas path length may increase with the chamber pressure and that it is also often dependent of the type of x-ray bullet.

Journal Article↗

Quantitative measurements of charging in a gaseous environment.

Charge accumulation in insulating or semiconducting samples due to electron beam irradiation is one of the key problems in electron microscopy. One of the most promising techniques for reducing the severity of such charging is to surround the sample with a low-pressure atmosphere of a gas. The charging behavior of a number of materials, surrounded by a variety of gases, has been determined to identify the important factors which control charging under these conditions. The magnitude of the surface potential was deduced from an analysis of x-ray spectra from the surface. The relationship between surface charge, gas pressure, and gas type are measured, and the charging reduction efficiency (CRE) is compared.

Journal Article↗

A novel technique for visualizing electron beam induced charging.

Charging is one of the most important problems encountered in scanning electron microscopy and as a result this phenomenon it has received a lot of both theoretical and experimental attention. Despite this, many questions remain about the nature and behavior of charging because of the limitations of the experimental techniques available to study it. For example, although it is now straightforward to determine in situ the surface potential of a sample that is charging during irradiation, it is difficult to measure the lateral extent of the charging, or its persistence once the incident beam is switched off. We describe here a simple technique which provides a rapid way of visualizing the temporal and spatial behavior of charging phenomena.

Journal Article↗

An experimental model of beam broadening in the variable pressure scanning electron microscope.

In the variable pressure scanning electron microscope (VP-SEM) the incident electrons pass through a gaseous environment and the beam is scattered by these interactions. We show here that the experimental intensity profile of the scattered beam can be described as Gaussian in form to a high level of accuracy. This provides a rapid means of accounting for the effects of beam scatter in imaging and microanalysis because the standard deviation of the Gaussian is a simple function of parameters such as working distance, beam energy, gas type and pressure.

Journal Article↗

Nanotip electron gun for the scanning electron microscope.

Experimental nanotips have shown significant improvement in the resolution performance of a cold field emission scanning electron microscope (SEM). Nanotip electron sources are very sharp electron emitter tips used as a replacement for the conventional tungsten field emission (FE) electron sources. Nanotips offer higher brightness and smaller electron source size. An electron microscope equipped with a nanotip electron gun can provide images with higher spatial resolution and with better signal-to-noise ratio. This could present a considerable advantage over the current SEM electron gun technology if the tips are sufficiently long-lasting and stable for practical use. In this study, an older field-emission critical dimension (CD) SEM was used as an experimental test platform. Substitution of tungsten nanotips for the regular cathodes required modification of the electron gun circuitry and preparation of nanotips that properly fit the electron gun assembly. In addition, this work contains the results of the modeling and theoretical calculation of the electron gun performance for regular and nanotips, the preparation of the SEM including the design and assembly of a measuring system for essential instrument parameters, design and modification of the electron gun control electronics, development of a procedure for tip exchange, and tests of regular emitter, sharp emitter and nanotips. Nanotip fabrication and characterization procedures were also developed. Using a "sharp" tip as an intermediate to the nanotip clearly demonstrated an improvement in the performance of the test SEM. This and the results of the theoretical assessment gave support for the installation of the nanotips as the next step and pointed to potentially even better performance. Images taken with experimental nanotips showed a minimum two-fold improvement in resolution performance than the specification of the test SEM. The stability of the nanotip electron gun was excellent; the tip stayed useful for high-resolution imaging for several hours during many days of tests. The tip lifetime was found to be several months in light use. This paper summarizes the current state of the work and points to future possibilities that will open when electron guns can be designed to take full advantage of the nanotip electron emitters.

Journal Article↗

Pressure effect of growing with electron beam-induced deposition with tungsten hexafluoride and tetraethylorthosilicate precursor.

Electron beam-induced deposition (EBID) provides a simple way to fabricate submicron- or nanometer-scale structures from various elements in a scanning electron microscope (SEM). The growth rate and shape of the deposits are influenced by many factors. We have studied the growth rate and morphology of EBID-deposited nanostructures as a function of the tungsten hexafluoride (WF6) and tetraethylorthosilicate (TEOS) precursor gas pressure and growth time, and we have used Monte Carlo simulations to model the growth of tungsten and silicon oxide to elucidate the mechanisms involved in the EBID growth. The lateral radius of the deposit decreases with increasing pressure because of the enhanced vertical growth rate which limits competing lateral broadening produced by secondary and forward-scattered electrons. The morphology difference between the conical SiO(x) and the cylindrical W nanopillars is related to the difference in interaction volume between the two materials. A key parameter is the residence time of the precursor gas molecules. This is an exponential function of the surface temperature; it changes during nanopillar growth and is a function of the nanopillar material and the beam conditions.

Journal Article↗