PubMed Health⌕ Search

Biomedical subjects

David Cory

Publications and source records attributed to David Cory.

4 recordsLinked to original sources

Reduction of spinning sidebands in proton NMR of human prostate tissue with slow high-resolution magic angle spinning.

High-resolution magic angle spinning (HRMAS) NMR spectroscopy has proven useful for analyzing intact tissue and permitting correlations to be made between tissue metabolites and disease pathologies. Extending these studies to slow-spinning methodologies helps protect tissue pathological structures from HRMAS centrifuging damage and may permit the study of larger objects. Spinning sidebands (SSBs), which are produced by slow spinning, must be suppressed to prevent the complication of metabolic spectral regions. In this study human prostate tissues, as well as gel samples of a metabolite mixture solution, were measured with continuous-wave (CW) water presaturation on a 14.1T spectrometer, with HRMAS spinning rates of 250, 300, 350, 600, and 700 Hz, and 3.0 kHz. Editing the spectra by means of a simple minimum function (Min(A, B, ..., N) for N spectra acquired at different but close spinning rates) produced SSB-free spectra. Statistically significant linear correlations were observed for metabolite concentrations quantified from the Min(A, B, ..., N)-edited spectra generated at low spinning rates, with concentrations measured from the 3 kHz spectra, and also with quantitative pathology. These results indicate the empirical utility of this scheme for analyzing intact tissue, which also may be used as an adjunct tool in pathology for diagnosing disease.

Algorithms↗

High-resolution magic angle spinning proton NMR analysis of human prostate tissue with slow spinning rates.

The development of high-resolution magic angle spinning (HR-MAS) NMR spectroscopy for intact tissue analysis and the correlations between the measured tissue metabolites and disease pathologies have inspired investigations of slow-spinning methodologies to maximize the protection of tissue pathology structures from HR-MAS centrifuging damage. Spinning sidebands produced by slow-rate spinning must be suppressed to prevent their complicating the spectral region of metabolites. Twenty-two human prostatectomy samples were analyzed on a 14.1T spectrometer, with HR-MAS spinning rates of 600 Hz, 700 Hz, and 3.0 kHz, a repetition time of 5 sec, and employing various rotor-synchronized suppression methods, including DANTE, WATERGATE, TOSS, and PASS pulse sequences. Among them, DANTE, as the simplest scheme, has shown the most potential in suppression of tissue water signals and spinning sidebands, as well as in quantifying metabolic concentrations.

Humans↗

Background gradient suppression in pulsed gradient stimulated echo measurements.

Pulsed gradient spin echo (PGSE) experiments can be used to measure the probability distribution of molecular displacements. In homogeneous samples this reports on the molecular diffusion coefficient, and in heterogeneous samples, such as porous media and biological tissue, such measurements provide information about the sample's morphology. In heterogeneous samples however background gradients are also present and prevent an accurate measurement of molecular displacements. The interference of time independent background gradients with the applied magnetic field gradients can be removed through the use of bipolar gradient pulses. However, when the background gradients are spatially non-uniform molecular diffusion introduces a temporal modulation of the background gradients. This defeats simple bipolar gradient suppression of background gradients in diffusion related measurements. Here we introduce a new method that requires the background gradients to be constant over coding intervals only. Since the coding intervals are typically at least an order of magnitude shorter than the storage time, this new method succeeds in suppressing cross-terms for a much wider range of heterogeneous samples.

Diffusion↗

MRI of insulitis in autoimmune diabetes.

Development of imaging techniques that would allow the mapping of immune cells in vivo could greatly aid our understanding of a number of inflammatory and autoimmune diseases. The current study focused on imaging of autoimmune destruction of the insulin-producing pancreatic beta-cells by cytotoxic lymphocytes, the cause of insulin-dependent diabetes mellitus (IDDM; Type 1 diabetes). Using high-resolution MR microscopy and a conventional clinical MR imaging system, it was possible to visualize the infiltration of immune cells in the diabetic mouse pancreas. Mouse lymphocytes were visualized by magnetically labeling them with recently developed magnetic nanoparticles (CLIO-Tat). The results from this study could potentially lead to detection of immune infiltration during diabetes formation in vivo, which would be one of the earliest parameters of disease development.

Adoptive Transfer↗